Skip to content

Commit

Permalink
Re #10881 Apparently, C++ diagnostics do not understand integer mon
Browse files Browse the repository at this point in the history
numbers. Shame. Have to revert this to folat monitor number.
  • Loading branch information
abuts committed Jan 23, 2015
1 parent fb1d338 commit 204574d
Show file tree
Hide file tree
Showing 6 changed files with 6 additions and 6 deletions.
2 changes: 1 addition & 1 deletion Code/Mantid/instrument/LET_Parameters.xml
Expand Up @@ -60,7 +60,7 @@
</parameter>

<!-- Monitor used to estimate total current on the sample while normalizing by monitor 1. -->
<parameter name="norm-mon1-spec" type = "int" >
<parameter name="norm-mon1-spec" >
<value val="40961"/>
</parameter>

Expand Down
2 changes: 1 addition & 1 deletion Code/Mantid/instrument/LET_Parameters_dr3to11.xml
Expand Up @@ -60,7 +60,7 @@
</parameter>

<!-- Monitor used to estimate total current on the sample while normalizing by monitor 1. -->
<parameter name="norm-mon1-spec" type = "int" >
<parameter name="norm-mon1-spec" >
<value val="73729"/>
</parameter>

Expand Down
2 changes: 1 addition & 1 deletion Code/Mantid/instrument/MAPS_Parameters.xml
Expand Up @@ -60,7 +60,7 @@
</parameter>

<!-- Monitor used to estimate total current on the sample while normalizing by monitor 1. -->
<parameter name="norm-mon1-spec" type = "int" >
<parameter name="norm-mon1-spec" >
<value val="41473"/>
</parameter>

Expand Down
2 changes: 1 addition & 1 deletion Code/Mantid/instrument/MARI_Parameters.xml
Expand Up @@ -60,7 +60,7 @@
</parameter>

<!-- Monitor used to estimate total current on the sample while normalizing by monitor 1. -->
<parameter name="norm-mon1-spec" type = "int">
<parameter name="norm-mon1-spec" >
<value val="1"/>
</parameter>
<!-- Time interval used for integration to estimate current on the sample
Expand Down
2 changes: 1 addition & 1 deletion Code/Mantid/instrument/MERLIN_Parameters.xml
Expand Up @@ -60,7 +60,7 @@
</parameter>

<!-- Monitor used to estimate total current on the sample while normalizing by monitor 1. -->
<parameter name="norm-mon1-spec" type = "int" >
<parameter name="norm-mon1-spec" >
<value val="69633"/>
</parameter>

Expand Down
2 changes: 1 addition & 1 deletion Code/Mantid/instrument/MERLIN_Parameters_after2013_4.xml
Expand Up @@ -60,7 +60,7 @@
</parameter>

<!-- Monitor used to estimate total current on the sample while normalizing by monitor 1. -->
<parameter name="norm-mon1-spec" type = "int" >
<parameter name="norm-mon1-spec" >
<value val="69633"/>
</parameter>

Expand Down

0 comments on commit 204574d