XBee Zigbee API Test Programme

Screenshots

  • Range Test ScreenShot of Range Test

    COM6 connected to a XBee router and COM3 connected to a coordinator. Router is sending ping packs to Coordinator in 50Hz. The ping pack is in the format of 'PXXXXXyyyyyyy', in which XXXXX means 5-digital index number and yyyyyyy is the input content.

    In the left picture, payload of each pack is 31 bytes with 28-bytes frame data. So the baudrate of payload is 15510bps and the rate of xbee serial is 29510(must be less than 115200). In the ping information line, the format is [good pack]/[lost pack]/[dup pack] C[total pack]/T[time in secs] [packets per secs]Pps/[bits per secs]bps.

    The log window shows detailed message and error-trackback informations .

Funtion support

  • AT command
  • Remote AT command
  • Send single TX request with response in const frequency
  • Send continuous TX requests with/without response in const frequency
  • Flow rate predict/measurement in Pps(Packet per Second) and bps(Bit per Second)
  • Echo RX response for range test(missing function of X-CTU in API mode)

Programme based on