New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Information on device screens are "auto toggling". #333
Comments
This issue has been mentioned on Meshtastic. There might be relevant details there: https://meshtastic.discourse.group/t/setting-displaying-node-names/1113/3 |
This issue has been mentioned on Meshtastic. There might be relevant details there: https://meshtastic.discourse.group/t/alpha-tester-thread-0-9-3-device-code-ready-for-testing/298/265 |
interesting - I'll create a 4 node net and try to repro/fix. |
Good point, I also thought about that, but it is the same behavior on both TBeams (inside or outside the case) and on both Heltec devices. (Also the dots are only changing on a real button press, so there is no crosstalk on the pcb or so.) There isn't a specific frequency or something related to an LED or so. On the heltec it switches the screens 1, 2, 3 with 1Hz and then there is a pause for about 3 seconds. After that again 1, 2, 3, pause, ... On Tbean it is constantly 1 second between the change. |
same happens here when I connect 1x SX1262 and 1x SX1278 and 2x SX1276: |
My TTGO T3 Lora32 board (possible other models too) does not have a button to switch screens, the switching screen is/was a solution to that I think. Now my screen does not autochange an I only have access to the 1st screen, can not even see the battery status. |
Hi, |
I downgraded to 0.9.3 and the screens switch now as before. Is the pusbutton documented in detail? |
Alas @PA7John you'll need to add a switch if you want to see different screens. I think only the lora32 is missing a switch. We could add an enhancement to "auto cycle between screens every N seconds" and use that feature on boards without a switch. If you want that would you mind putting in a bug so we don't forget (though it won't be super soon unless someone else does it) |
That might help adding a pushbutton. I am not very familiar with the board names, but this thread covers a lot of LoRa32 boards. https://meshtastic.discourse.group/t/ttgo-lora32-v2-v1-6-button/522/8 |
Ok, thank you. Will look into the push button. |
Hi,
I have Tbeam v 1.1 sx1262 and heltec hardware. On both the device info screens are not still and the information is toggling automatically.
It does not matter which of the three device screens are selected in my mesh of 4 devices. on every page the info is changing once a second or less.
Already mentioned here:
https://meshtastic.discourse.group/t/setting-displaying-node-names/1113
Edit: added gif to demonstrate the issue:
The text was updated successfully, but these errors were encountered: