The psus:
section of your config is where you power supply units. See
Voltages and Power in Pinball Machines for
details about voltages in pinball machines and some electric details.
Then specify to which PSU your coils: are connected. This is used for power management. In some
cases, MPF ,ay deliberately delay coil pulses to prevent too many coils
from firing and drawing to much current from your PSU.
Ball devices and
drop target do this by
default to ensure more consistent pulses.
The following sections are optional in the psus:
section of your
config. (If you don't include them, the default will be used).
Single value, type: integer
. Defaults to empty.
Maximum ampers which can be provided by this PSU. Currently not used.
Single value, type: time string (ms)
(Instructions for entering time strings). Default: 10
Time to wait after a coil pulse.
Single value, type: integer
. Defaults to empty.
Voltage of your PSU. Only informal.
Single value, type: one of the following options: none, basic, full.
Default: basic
Log level for the console log for this device.
Single value, type: boolean
(true
/false
). Default: false
Set this to true to see additional debug output. This might impact the performance of MPF.
Single value, type: one of the following options: none, basic, full.
Default: basic
Log level for the file log for this device.
Single value, type: string
. Default: %
Name of this device in service mode.
List of one (or more) values, each is a type: string
. Defaults to
empty.
Currently unused.