Fix propagation of excitation leakage factor #2403
Labels
bug
Critical/severe issue
L: Magnetic.FundamentalWave
Issue addresses Modelica.Magnetic.FundamentalWave
L: Magnetic.QuasiStatic
Issue addresses Modelica.Magnetic.QuasiStatic
Milestone
The examples in
Modelica.Magnetic.QuasiStatic.FundamentalWave.Examples.BasicMachines
rely on multi phase machines with phase parameterm
. In order investigate phase numbers greater than three, the resistances and inductances are multiplied by the factorm/3
. This way the power balances of the investigates machines are equal to three phase machines, when using the same voltage magnitudes. In the examples of the tranisient electrical excited synchronous machines it was forgotten to propagate this factor to the excitation leakage factorsigmae
.The same issue applies to
Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.SMEE_Generator_MultiPhase
.The text was updated successfully, but these errors were encountered: