Connect(p, p) in Modelica.Electrical.Analog.Examples.Utilities.SwitchedCapacitor? #4245

Closed
TongYuan-MC opened this issue Jan 6, 2024 · 2 comments · Fixed by #4261
Closed
Assignees
Labels
example Issue only addresses example(s) L: Electrical.Analog Issue addresses Modelica.Electrical.Analog
Milestone

Comments

@TongYuan-MC
Copy link

What is the purpose of connect(p, p)?Whether it is a valid connect-equation?
image

@AHaumer
Copy link
Contributor

AHaumer commented Jan 6, 2024

I suppose that is a bug.
If you release the mouse button during a connection too early, you get such a connection with zero length.
To me it seems that it doesn't affect the results, but we should remove it.

@HansOlsson
Copy link
Contributor

I suppose that is a bug. If you release the mouse button during a connection too early, you get such a connection with zero length. To me it seems that it doesn't affect the results, but we should remove it.

Agreed. Specifically it doesn't impact the result if there are other connection(s) to p, and two lines above we see another connection to p: connect(IdealCommutingSwitch1.n1, p).

@beutlich beutlich added L: Electrical.Analog Issue addresses Modelica.Electrical.Analog example Issue only addresses example(s) labels Jan 9, 2024
AHaumer added a commit to AHaumer/ModelicaStandardLibrary that referenced this issue Jan 14, 2024
@beutlich beutlich linked a pull request Jan 14, 2024 that will close this issue
AHaumer added a commit that referenced this issue Jan 14, 2024
@beutlich beutlich added this to the MSL4.1.0 milestone Jan 14, 2024