Oh gosh. I had experienced this problem before but forgot to post it. I -Chris On Wed, May 21, 2014 at 9:09 PM, Mostapha Sadeghipour Roudsari <
|
For some reason it is back! http://www.grasshopper3d.com/group/ladybug/forum/topics/one-doubt-about-radiation-data Can you take care of this once more @chriswmackey? Thanks. |
@mostaphaRoudsari , I take a look into it and have it taken care of for the release. I think that we each thought that the other was going to fix the issue and neither of us ended up addressing it. |
@chriswmackey thanks! |
http://www.grasshopper3d.com/xn/detail/2985220:Comment:1073935
"The RadiationAnalysis component mentions it returns values in Wh/m2 and Wh, but the generated legend says kWh/m2. The latter seems to be right."
@chriswmackey this is actually half true. If the sky is generated for a single HOY the result will be in Wh/m2. In case of annual sky the values will be kWh/m2. I'm not sure how do we want to manage this?