Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[Alphanumerics] Alphanumeric Telemetry Views in Display Layouts Bounds Issue #5130

Closed
3 of 5 tasks
jvigliotta opened this issue Apr 27, 2022 · 4 comments
Closed
3 of 5 tasks

Comments

@jvigliotta
Copy link
Contributor

Summary

Expected vs Current Behavior

Steps to Reproduce

  1. Add an Alphanumeric view of telemetry to a display layout
  2. Add the same view as a telemetry table (for comparison)
  3. In local clock mode, add a 5 second end offset
  4. Switch to fixed time, notice the telemetry table will finish out the 5 second offset (end bounds), but the alphanumeric just stops immediately

Impact Check List

  • Data loss or misrepresented data?
  • Regression? Did this used to work or has it always been broken?
  • Is there a workaround available? (other views, but not really)
  • Does this impact a critical component?
  • Is this just a visual bug with no functional impact?

Additional Information

Screen.Recording.2022-04-27.at.3.28.28.PM.mov
@jvigliotta jvigliotta self-assigned this Apr 27, 2022
@jvigliotta
Copy link
Contributor Author

Testing

  • just perform the reproduction steps and make sure the telemetry still comes in after switching to fixed time

@akhenry
Copy link
Contributor

akhenry commented Apr 28, 2022

Good catch!

@charlesh88
Copy link
Contributor

Verified fixed Testathon 4/28/22

@akhenry
Copy link
Contributor

akhenry commented Apr 28, 2022

Verified fixed

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment