PMS5003 gives no reading after NAMF-2020-38 #36

Closed
blassepl opened this issue Aug 22, 2021 · 5 comments
Closed

PMS5003 gives no reading after NAMF-2020-38 #36

blassepl opened this issue Aug 22, 2021 · 5 comments

Comments

@blassepl
Copy link

blassepl commented Aug 22, 2021

After upgrading to NAMF-2020-38 PMS5003 stopped working.

image

After connecting via serial no error can be seen in console, however PMSx003 reading are not providing any results. Tested on two devices, same result on both.

image

@netmaniac
Copy link
Contributor

I don't have PMS sensor available to test it, but could You switch one of sensor to beta update channel? I have released new beta with a bit bigger buffer size for PMS/SDS replies. This is only changed thing (regarding PMS) between 37 and 38. Does it work on new beta?

@blassepl
Copy link
Author

Still not working. Reading on new beta:
image

And the same on NAMF-2020-37:
image

@netmaniac
Copy link
Contributor

OK, I'll get one PMS sensor and will test it.

@netmaniac
Copy link
Contributor

There is new release on update server (beta NAMF-2020-40rc2). Should fix problem with PMS. Could You verify that?

@blassepl
Copy link
Author

blassepl commented Sep 6, 2021

Sorry for the delay. Confirmed working with 40rc2.