This is a simple DICOM to NIfTI validator script and dataset based on Siemens XA30 DICOM images.

Siemens notes that XA30 systems can export DICOMs in one of two modes:

  • Interoperability: assures that the data is compatible to any DICOM node, but enhanced features cannot be guaranteed.

  • Enhanced: preserves the enhanced features of the source images.

This repository contains data saved in Interoperability mode, see dcm_qa_xa30 for Enhanced mode data. An identical acquisition will populate different tags depending on whether Interoperability or Enhanced mode is selected. The table below highlights differences from dcm2niix's perspective:

BIDS field Interoperability Enhanced
ImagingFrequency 0018,0084 0018,9098
PhaseEncodingSteps 0018,0089 0018,9231
SAR 0018,1316 0018,9181
MTState ? 0018,9020
AcquisitionDuration ? 0018,9073

Details

Images were acquired by Hu Cheng, Isaiah Innis, and Daniel Levitas using a Siemens Prisma Fit running XA30 at Indiana University. Additional sequence details are provided in the dcm_qa_xa30 PDF-format file.

  • Common Parameters
    • Manufacturer: Siemens
    • Model: Prisma Fit
    • Software Versions: MR XA30
Series Sequence name
5-6 anat-T1w_acq-tfl
7-8 func-bold_task-fa_run-1
9-10 gre_field_mapping
11-17 DWI_dir80_PA
18-20 asl_2d_tra

Running

Assuming that the executable dcm2niix is in your path, you should be able to simply run the script batch.sh from the terminal.