Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

How to switch to external LO using bladerf-cli #935

Closed
maurokenny opened this issue Aug 24, 2023 · 1 comment
Closed

How to switch to external LO using bladerf-cli #935

maurokenny opened this issue Aug 24, 2023 · 1 comment

Comments

@maurokenny
Copy link

Hi,

I would like know how to switch to an external LO instead of using the internal LO. Is there any chance that bladerf-cli is capable of doing that?

Thanks,

@paulhprobert
Copy link

f you do:
bladeRF-cli -i
Then do:
bladeRF>help set
Then you'll get a list of settings you can enter. Down at the bottom are bladeRF2 only settings. You are
interested in clock_ref to enable the external input and refin_freq to set the value. You should supply a clock, 10 MHz for example,
with a peak to peak value no greater than 3.3 volts, to the J95 REFIN connector.