Axone only-Mux settings for TOD refclk input
Browse files Browse the repository at this point in the history
Change-Id: Ie7347a3de7c760dcdb875516c07f470e94f7f027
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/61851
Reviewed-by: Soma Bhanutej <soma.bhanu@in.ibm.com>
Tested-by: Jenkins Server <pfd-jenkins+hostboot@us.ibm.com>
Tested-by: PPE CI <ppe-ci+hostboot@us.ibm.com>
Tested-by: Hostboot CI <hostboot-ci+hostboot@us.ibm.com>
Reviewed-by: Sachin Gupta <sgupta2m@in.ibm.com>
Reviewed-by: Jennifer A. Stofer <stofer@us.ibm.com>
Reviewed-on: http://rchgit01.rchland.ibm.com/gerrit1/61856
Tested-by: Jenkins OP Build CI <op-jenkins+hostboot@us.ibm.com>
Tested-by: Jenkins OP HW <op-hw-jenkins+hostboot@us.ibm.com>
Tested-by: FSP CI Jenkins <fsp-CI-jenkins+hostboot@us.ibm.com>
Reviewed-by: Christian R. Geddes <crgeddes@us.ibm.com>
Disable-CI: Christian R. Geddes <crgeddes@us.ibm.com>
  • Loading branch information
anusrang authored and crgeddes committed Sep 10, 2018
1 parent 2c1001a commit 09370fc
Showing 1 changed file with 13 additions and 0 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -37,6 +37,19 @@
<initToZero/>
</attribute>

<attribute>
<id>ATTR_CLOCK_PLL_MUX_TOD</id>
<targetType>TARGET_TYPE_PROC_CHIP</targetType>
<description>
Axone only - setup clock mux settings for TOD Refclk input
0b0 = 16 MHz I/O Filter PLL Output
0b1 = 32 MHz LPC reference clock
</description>
<valueType>uint8</valueType>
<platInit/>
<initToZero/>
</attribute>

<attribute>
<id>ATTR_CLOCK_PLL_MUX</id>
<targetType>TARGET_TYPE_PROC_CHIP</targetType>
Expand Down