Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

fix client handler fault state #1643

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Jump to
Jump to file
Failed to load files.
Diff view
Diff view
Original file line number Diff line number Diff line change
Expand Up @@ -10,7 +10,6 @@
from modules.common.abstract_device import DeviceDescriptor
from modules.common.component_context import SingleComponentUpdateContext
from modules.common.fault_state import ComponentInfo, FaultState
from modules.common.hardware_check_context import SeriesHardwareCheckContext
from modules.common.store import get_chargepoint_value_store
from modules.common.component_state import ChargepointState
from modules.common.version_by_telnet import get_version_by_telnet
Expand Down Expand Up @@ -75,29 +74,30 @@ def get_values(self) -> None:
if self.version is not None:
with self.__client_error_context:
try:
with SeriesHardwareCheckContext(self._client):
if self.version is False:
raise ValueError(
"Firmware des openWB Satellit ist nicht mit openWB 2 kompatibel. "
"Bitte den Support kontaktieren.")
self.delay_second_cp(self.CP0_DELAY)
with self._client.client:
currents = self._client.meter_client.get_currents()
phases_in_use = sum(1 for current in currents if current > 3)
plug_state, charge_state, _ = self._client.evse_client.get_plug_charge_state()
self._client.check_hardware(self.fault_state)
if self.version is False:
raise ValueError(
"Firmware des openWB Satellit ist nicht mit openWB 2 kompatibel. "
"Bitte den Support kontaktieren.")
self.delay_second_cp(self.CP0_DELAY)
with self._client.client:
currents = self._client.meter_client.get_currents()
phases_in_use = sum(1 for current in currents if current > 3)
plug_state, charge_state, _ = self._client.evse_client.get_plug_charge_state()

chargepoint_state = ChargepointState(
power=self._client.meter_client.get_power()[1],
currents=currents,
imported=self._client.meter_client.get_imported(),
exported=0,
voltages=self._client.meter_client.get_voltages(),
plug_state=plug_state,
charge_state=charge_state,
phases_in_use=phases_in_use,
serial_number=self._client.meter_client.get_serial_number()
)
self.store.set(chargepoint_state)
chargepoint_state = ChargepointState(
power=self._client.meter_client.get_power()[1],
currents=currents,
imported=self._client.meter_client.get_imported(),
exported=0,
voltages=self._client.meter_client.get_voltages(),
plug_state=plug_state,
charge_state=charge_state,
phases_in_use=phases_in_use,
serial_number=self._client.meter_client.get_serial_number()
)
self.store.set(chargepoint_state)
self.__client_error_context.reset_error_counter()
except AttributeError:
self._create_client()
self._validate_version()
Expand All @@ -107,16 +107,18 @@ def get_values(self) -> None:

def set_current(self, current: float) -> None:
if self.version is not None:
if self.__client_error_context.error_counter_exceeded():
current = 0
with SingleComponentUpdateContext(self.fault_state, update_always=False):
with self.__client_error_context:
try:
with SeriesHardwareCheckContext(self._client):
self.delay_second_cp(self.CP0_DELAY)
with self._client.client:
if self.version:
self._client.evse_client.set_current(int(current))
else:
self._client.evse_client.set_current(0)
self._client.check_hardware(self.fault_state)
self.delay_second_cp(self.CP0_DELAY)
with self._client.client:
if self.version:
self._client.evse_client.set_current(int(current))
else:
self._client.evse_client.set_current(0)
except AttributeError:
self._create_client()
self._validate_version()
Expand All @@ -126,20 +128,20 @@ def switch_phases(self, phases_to_use: int, duration: int) -> None:
with SingleComponentUpdateContext(self.fault_state, update_always=False):
with self.__client_error_context:
try:
with SeriesHardwareCheckContext(self._client):
with self._client.client:
if phases_to_use == 1:
self._client.client.delegate.write_register(
0x0001, 256, unit=self.ID_PHASE_SWITCH_UNIT)
time.sleep(1)
self._client.client.delegate.write_register(
0x0001, 512, unit=self.ID_PHASE_SWITCH_UNIT)
else:
self._client.client.delegate.write_register(
0x0002, 512, unit=self.ID_PHASE_SWITCH_UNIT)
time.sleep(1)
self._client.client.delegate.write_register(
0x0002, 256, unit=self.ID_PHASE_SWITCH_UNIT)
self._client.check_hardware(self.fault_state)
with self._client.client:
if phases_to_use == 1:
self._client.client.delegate.write_register(
0x0001, 256, unit=self.ID_PHASE_SWITCH_UNIT)
time.sleep(1)
self._client.client.delegate.write_register(
0x0001, 512, unit=self.ID_PHASE_SWITCH_UNIT)
else:
self._client.client.delegate.write_register(
0x0002, 512, unit=self.ID_PHASE_SWITCH_UNIT)
time.sleep(1)
self._client.client.delegate.write_register(
0x0002, 256, unit=self.ID_PHASE_SWITCH_UNIT)
except AttributeError:
self._create_client()
self._validate_version()
Expand Down
4 changes: 2 additions & 2 deletions packages/modules/common/hardware_check.py
Original file line number Diff line number Diff line change
Expand Up @@ -63,7 +63,7 @@ def handle_exception(self: ClientHandlerProtocol, exception: Exception):
else:
return False

def check_hardware(self: ClientHandlerProtocol):
def check_hardware(self: ClientHandlerProtocol, fault_state: FaultState):

try:
if self.evse_client.get_firmware_version() > EVSE_MIN_FIRMWARE:
Expand All @@ -81,7 +81,7 @@ def check_hardware(self: ClientHandlerProtocol):
if meter_check_passed is False:
raise Exception(meter_error_msg)
elif meter_check_passed and meter_error_msg is not None:
self.fault_state.warning(meter_error_msg)
fault_state.warning(meter_error_msg)
if evse_check_passed is False:
raise Exception(EVSE_BROKEN)

Expand Down
13 changes: 0 additions & 13 deletions packages/modules/common/hardware_check_context.py

This file was deleted.

Original file line number Diff line number Diff line change
Expand Up @@ -63,7 +63,7 @@ def store_state(chargepoint_state: ChargepointState) -> None:
self.store_internal.set(chargepoint_state)
self.store_internal.update()
try:
self._client.check_hardware()
self._client.check_hardware(self.fault_state)
powers, power = self._client.meter_client.get_power()
if power < self.PLUG_STANDBY_POWER_THRESHOLD:
power = 0
Expand Down
3 changes: 1 addition & 2 deletions packages/modules/internal_chargepoint_handler/clients.py
Original file line number Diff line number Diff line change
Expand Up @@ -36,11 +36,10 @@ def __init__(self,
fault_state: FaultState) -> None:
self.client = client
self.local_charge_point_num = local_charge_point_num
self.fault_state = fault_state
self.evse_client = self._evse_factory(client, evse_ids)
self.meter_client = self.find_meter_client(CP0_METERS if self.local_charge_point_num == 0 else CP1_METERS,
client)
self.check_hardware()
self.check_hardware(fault_state)
self.read_error = 0

def _evse_factory(self, client: Union[ModbusSerialClient_, ModbusTcpClient_], evse_ids: List[int]) -> evse.Evse:
Expand Down