[lutron] Explicitly enable proper monitoring types for HomeWorks connections #11726

Merged
merged 2 commits into from
Dec 7, 2021
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
Expand Up @@ -33,6 +33,7 @@
import org.openhab.binding.lutron.internal.protocol.LutronCommandNew;
import org.openhab.binding.lutron.internal.protocol.lip.LutronCommandType;
import org.openhab.binding.lutron.internal.protocol.lip.LutronOperation;
import org.openhab.binding.lutron.internal.protocol.lip.Monitoring;
import org.openhab.binding.lutron.internal.protocol.lip.TargetType;
import org.openhab.core.thing.Bridge;
import org.openhab.core.thing.ChannelUID;
Expand All @@ -57,11 +58,6 @@ public class IPBridgeHandler extends LutronBridgeHandler {

private static final String DB_UPDATE_DATE_FORMAT = "MM/dd/yyyy HH:mm:ss";

private static final Integer MONITOR_PROMPT = 12;
private static final Integer MONITOR_SYSVAR = 10;
private static final Integer MONITOR_ENABLE = 1;
private static final Integer MONITOR_DISABLE = 2;

private static final Integer SYSTEM_DBEXPORTDATETIME = 10;

private static final int MAX_LOGIN_ATTEMPTS = 2;
Expand Down Expand Up @@ -208,8 +204,9 @@ private synchronized void connect() {

// Disable prompts
sendCommand(new LIPCommand(TargetType.BRIDGE, LutronOperation.EXECUTE, LutronCommandType.MONITORING, null,
MONITOR_PROMPT, MONITOR_DISABLE));
Monitoring.PROMPT, Monitoring.ACTION_DISABLE));

initMonitoring();
if (requireSysvarMonitoring.get()) {
setSysvarMonitoring(true);
}
Expand Down Expand Up @@ -457,10 +454,17 @@ private void scanForDevices() {
}
}

private void initMonitoring() {
for (Integer monitorType : Monitoring.REQUIRED_SET) {
sendCommand(new LIPCommand(TargetType.BRIDGE, LutronOperation.EXECUTE, LutronCommandType.MONITORING, null,
monitorType, Monitoring.ACTION_ENABLE));
}
}

private void setSysvarMonitoring(boolean enable) {
Integer setting = (enable) ? MONITOR_ENABLE : MONITOR_DISABLE;
Integer setting = (enable) ? Monitoring.ACTION_ENABLE : Monitoring.ACTION_DISABLE;
sendCommand(new LIPCommand(TargetType.BRIDGE, LutronOperation.EXECUTE, LutronCommandType.MONITORING, null,
MONITOR_SYSVAR, setting));
Monitoring.SYSVAR, setting));
}

@Override
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,62 @@
/**
* Copyright (c) 2010-2021 Contributors to the openHAB project
*
* See the NOTICE file(s) distributed with this work for additional
* information.
*
* This program and the accompanying materials are made available under the
* terms of the Eclipse Public License 2.0 which is available at
* http://www.eclipse.org/legal/epl-2.0
*
* SPDX-License-Identifier: EPL-2.0
*/
package org.openhab.binding.lutron.internal.protocol.lip;

import java.util.Set;

import org.eclipse.jdt.annotation.NonNullByDefault;

/**
* The {@link Monitoring} class defines constants for LIP Monitoring types
*
* @author Bob Adair - Initial contribution
*/
@NonNullByDefault
public class Monitoring {
// Monitoring Actions
public static final Integer ACTION_ENABLE = 1;
public static final Integer ACTION_DISABLE = 2;

// Monitoring Types
public static final Integer DIAG = 1;
public static final Integer EVENT = 2;
public static final Integer BUTTON = 3;
public static final Integer LED = 4;
public static final Integer ZONE = 5;
public static final Integer OCCUPANCY = 6;
public static final Integer PHOTOSENSOR = 7;
public static final Integer SCENE = 8;
public static final Integer TIMECLOCK = 9;
public static final Integer SYSVAR = 10;
public static final Integer REPLY = 11;
public static final Integer PROMPT = 12;
public static final Integer DEVICE = 14;
public static final Integer ADDRESS = 15;
public static final Integer SEQUENCE = 16;
public static final Integer HVAC = 17;
public static final Integer MODE = 18;
public static final Integer PRESET = 19;
public static final Integer L1RUNTIME = 20;
public static final Integer L2RUNTIME = 21;
public static final Integer DIAGERROR = 22;
public static final Integer SHADEGRP = 23;
public static final Integer PARTITION = 24;
public static final Integer SYSTEM = 25;
public static final Integer SENSORGROUP = 26;
public static final Integer TEMPSENSOR = 27;
public static final Integer ALL = 255;

/** Set of monitoring types which must be enabled */
public static final Set<Integer> REQUIRED_SET = Set.of(BUTTON, LED, ZONE, OCCUPANCY, SCENE, TIMECLOCK, REPLY, HVAC,
MODE);
}