Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

INT_BEAM, typo in Manual, bad response for ISECT=2, NITR=2 #926

Closed
SonSiont opened this issue Dec 20, 2022 · 2 comments
Closed

INT_BEAM, typo in Manual, bad response for ISECT=2, NITR=2 #926

SonSiont opened this issue Dec 20, 2022 · 2 comments
Assignees

Comments

@SonSiont
Copy link

Describe the bug
The bending moment in a beam should be the inverse of the reaction moment.
With INT_BEAM, ISECT=2, NITR=2 section, there is a high deviation.
The Radioss Reference Guide has in the description /ANIM/BEAM maybe a typo for the plastic strains.

To Reproduce
Run the model and compare the bending moment of element 2111 as in the figure in the attached pdf.

Expected behavior
Correction of the manual regarding EPSP vs. ESPN/N. Extent the section description, give a warning in
the manual for the mentioned plastic beam.

Output
A pdf file with detailed explanations and the Radioss files are in the archive.

Desktop (please complete the following information):

  • Version 6cf5b43
  • Hardware Intel
  • Configuration SMP with one thread

Additional context

@SonSiont
Copy link
Author

beamissue.tar.gz

@bertrand-altair
Copy link
Collaborator

Issue was investigated, and a report written
Radioss_Beam_report.docx

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests