Intel vCMTS on OpenShift

Table of Contents

Introduction

This document describes how to build, install and run the Intel vCMTS reference dataplane system on Red Hat OpenShift Container Platform. Intel vCMTS includes a DPDK Pktgen based cable traffic generation system for upstream and downstream traffic simulation.

Prerequisities

Ensure to have the following elements in hand and/or deployed. For the various operators, following the links to see how they can be deployed.

Setup internal image resitry (if not setup already)

oc apply -f config/image-registry/pvc.yaml
oc patch configs.imageregistry.operator.openshift.io cluster --type merge --patch '{"spec":{"managementState":"Managed"}}'
oc patch configs.imageregistry.operator.openshift.io cluster --type merge --patch '{"spec":{"storage":{"pvc":{"claim":"image-registry-storage"}}}}'

Setup ODF (if not setup already)

Scripts have been provided under config/odf to help boostrap an Ceph Cluster over two nodes. This is not a supported deployment and we advice using minimum 3 nodes.

Build Container Images

They are two ways to build the vCMTS related applications, please see build options.

Machine configuration

By default, an OpenShift cluster have two node roles (master and worker), identified by their respective MachineConfigPool and machineconfiguration.openshift.io/role label.

Each MachineConfigPool is a collection of MachineConfig identified by the label machineconfiguration.openshift.io/role.

This is what will drive the underlying node operating system configuration. Learn more about this here

As part of the vCMTS environment, we need to dedicate and customize two worker nodes with specific configuration:

  • one node for traffic generation (that will host DPDK Pktgen application).
  • one node for Intel vCMTS application.

To do so, we start by adding labels to each node, identifying their function.

FIXME: use only one label (the second label is used to deploy the vCMTS or pktgen)

oc label $NODE_FOR_VCMTS node-role.kubernetes.io/vcmts: ''
oc label $NODE_FOR_VCMTS vcmts=true

oc label $NODE_FOR_PKTGEN node-role.kubernetes.io/pktgen: ''
oc label $NODE_FOR_PKTGEN vcmtspktgen: "true"

Then we create a MachineConfigPool for each node type, identified by their label using a nodeSelector. Also, when creating the MachineConfigPool, the label machineconfiguration.openshift.io/role gets defined to identify MachineConfig belonging to that node role.

Both the vCMTS and pktgen MachineConfigPool will inherit from the MachineConfig targetting nodes having the node-role.kubernetes.io/worker: '' label, given it is part of their machineConfigSelector. In addition to that, they will inhirit from their respective MachineConfig.

Review and create the MachineConfigPool.

oc create -f config/mcp/vcmts.yaml
oc create -f config/mcp/pktgen.yaml

After a few minutes, they will have rendered their respective configuration (that is, so far, only comprised on MachineConfig of workers, given we haven't yet added any MachineConfig for our specific node types).

Performance Addon Operator Configuration

In order to enable advanced node performance tunings, we are using the Performance Addon Operator.

Both the vCMTS and pktgen nodes need to be configured with appropriate CPU isolation and Hugepages.

In our enrivonment, each node has two sockets, each with one CPU having 32 cores; for a total of 128 hyperthreaded cores.

Given the vCMTS required dedication of 4 cores per instance, to have 28 Service Groups, we need 28*4=112 cores.

As such, the vcmts profile is reserving 8 cores for house keeping and isolates the 120 remaining.

The pktgen only dedicates 2 cores per instance, but it is provided with similar configuration.

Their corresponding profiles have been defined and can be applied as follow.

oc apply -f config/pao/vcmts-profile.yaml
oc apply -f config/pao/pktgen-profile.yaml

This will generate MachineConfig targetting node identified by the nodeSelector field in the profile.

They can be seen using the following command

$ oc get MachineConfig -l machineconfiguration.openshift.io/role=vcmts
NAME                            GENERATEDBYCONTROLLER                      IGNITIONVERSION   AGE
50-nto-vcmts                                                               3.2.0             101d
50-performance-vcmts-profile0                                              3.2.0             101d
99-vcmts-generated-kubelet      1aeaf8c9c93dc772e65e23668dd435d06d833bcf   3.2.0             101d

$ oc get MachineConfig -l machineconfiguration.openshift.io/role=pktgen
NAME                             GENERATEDBYCONTROLLER                      IGNITIONVERSION   AGE
50-nto-pktgen                                                               3.2.0             101d
50-performance-pktgen-profile0                                              3.2.0             101d
99-pktgen-generated-kubelet-1    1aeaf8c9c93dc772e65e23668dd435d06d833bcf   3.2.0             101d

The machine config operator will see these new MachineConfig and will render the new target configuration for the respective MachineConfigPool. Once rendered, the configuration will be applied on the node part by the updated MachineConfigPool.

QAT configuration

Prerequisites

vfio-pci kernel module has QAT included on it's deny list on latest kernel versions hence we need to disable the deny list by unloading the module and re-loading it. NOTE: ensure no dataplane applications using devices bound to vfio-pci driver are running when doing this step.

(not recommanded) To perform these steps manually, log on the vcmts-d server and run the following commands: ~~~ sudo rmmod vfio-pci sudo modprobe vfio-pci disable_denylist=1 ~~~

(recommanded) Apply the vfio-pci kernel module config using a MachineConfig, making this configuration persistent to upgrades. oc create -f 100-worker-vfiopci.yaml

Instalation

  1. Install Node Feature Discovery operator

    oc apply -f config/nfd/nfd-sub.yaml
    
  2. Create NFD namespace and instance specifying '0b40' as the device class

    oc create ns openshift-nfd
    oc create -f config/nfd/node-feature-discovery.yaml
    
  3. Install the Intel Device Plugins Operator Allow the default Service Account to run pod using any user ID

    oc adm policy add-scc-to-user hostmount-anyuid -z default  -n openshift-operators
    

    Install the OperatorHub CatalogSource and the plugin

    oc create -f config/inteldeviceplugins/catalog-source.yaml
    oc apply -f config/inteldeviceplugins/inteldeviceplugins-sub.yaml
    
  4. Create the QAT VFs

    oc create ns inteldeviceplugins-system
    oc create -f qat-sriov-numvfs.yaml
    
  5. Create the QatDevicePlugin custom resource definition

    oc create -f qat-device-plugin.yaml
    

    The initial deployment of the QAT Device Plugin will fail. The daemonset needs to be given privilege in order to run correctly.

    oc patch daemonset/intel-qat-plugin -n openshift-operators --type=json -p='[{"op": "add", "path": "/spec/template/spec/containers/0/securityContext/privileged", "value": true}]'
    
  6. Verify it is running

    $ oc get all -n openshift-operators | grep qat
    pod/intel-qat-plugin-kn4gn                                   1/1     Running   1          20h
    daemonset.apps/intel-qat-plugin   1         1         1       1            1           vcmts=true      22h
    
  7. Verify QAT devices are available from the node

    $ oc get node rhtcyp002.npgcable.intel.com -o json | jq .status.allocatable | grep qat
    "qat.intel.com/generic": "96"
    

SRIOV Configuration

Both servers are connected back-to-back with 4 E810 network interfaces (one port per NIC).

In order to have 28 Service Group, we need 14 VFs per PF, for a total of 56 VFs per server, because each instance will have dedicated upstream and downstream VF, i.e. 28*2=56.

Virtual functions (VFs) from the same physical function (PF) are split into two resource pools in order to segragate and dedicate upstream and downstream traffic. In order to have 28 Service Group, we need 14 VFs per PF. The first 7 will be for downstream traffic and the last 7 for upstream traffic.

Also, as mentioned previously, each NUMA node have two NICs; in order to cross NUMA bounderies, we are creating one upstream and downstream network per NIC, that will be assigned following Service Group ID. This is the case for both vCMTS and pktgen.

So

  • the first 7 Service Groups (0-6) will be on NIC 0 of NUMA 0
  • the following 7 Service Groups(7-13) will be on NIC 1 of NUMA 0
  • the following 7 Service Groups(14-20) will be on NIC 2 of NUMA 1
  • the following 7 Service Groups(21-27) will be on NIC 3 of NUMA 2

This will ensure maximum throughput efficiency given the NIC are cabled back to back.

Note: the SRIOV configuration would be different in a routed fabric

Here is an overall diagram showing the setup

Start by applying the SriovNetworkNodePolicy to configure the VF in the PFs.

oc apply -f config/sriov/node-policy/

You can see the created network policies as follow

$ oc get SriovNetworkNodePolicy -n openshift-sriov-network-operator
NAME          AGE
default       100d
pktgen-ds-0   5d20h
pktgen-ds-1   5d20h
pktgen-ds-2   5d20h
pktgen-ds-3   5d20h
pktgen-us-0   5d20h
pktgen-us-1   5d20h
pktgen-us-2   5d20h
pktgen-us-3   5d20h
vcmts-ds-0    5d20h
vcmts-ds-1    5d20h
vcmts-ds-2    5d20h
vcmts-ds-3    5d20h
vcmts-us-0    5d20h
vcmts-us-1    5d20h
vcmts-us-2    5d20h
vcmts-us-3    5d20h

Now, we can create the SriovNetwork, which will consume the resources previously created.

oc apply -f config/sriov/network/

Validate all the network have been created

$ oc get SriovNetwork -n openshift-sriov-network-operator
NAME          AGE
pktgen-ds-0   5d20h
pktgen-ds-1   5d20h
pktgen-ds-2   5d20h
pktgen-ds-3   5d20h
pktgen-us-0   5d20h
pktgen-us-1   5d20h
pktgen-us-2   5d20h
pktgen-us-3   5d20h
vcmts-ds-0    5d20h
vcmts-ds-1    5d20h
vcmts-ds-2    5d20h
vcmts-ds-3    5d20h
vcmts-us-0    5d20h
vcmts-us-1    5d20h
vcmts-us-2    5d20h
vcmts-us-3    5d20h

The SR-IOV operator will generate NetworkAttachmentDefinition out of the created SriovNetwork.

This is what will be reference in the pod annotation k8s.v1.cni.cncf.io/networks to properly create and attach the VF interfaces.

You can verify the network attachement are created by running the following command.

$ oc get net-attach-def -n vcmts-build
NAME          AGE
pktgen-ds-0   5d20h
pktgen-ds-1   5d20h
pktgen-ds-2   5d20h
pktgen-ds-3   5d20h
pktgen-us-0   5d20h
pktgen-us-1   5d20h
pktgen-us-2   5d20h
pktgen-us-3   5d20h
vcmts-ds-0    5d20h
vcmts-ds-1    5d20h
vcmts-ds-2    5d20h
vcmts-ds-3    5d20h
vcmts-us-0    5d20h
vcmts-us-1    5d20h
vcmts-us-2    5d20h
vcmts-us-3    5d20h

Monitoring

In order to monitor the overall solution's performance and health, vCMTS comes with pre-built Grafana dashboard and monitoring capabilities. These monitoring capabilities presently require a high level of privilege, given they rely on a shared collectd socket.

As such, some ordering is required during the setup.

  1. First collectd needs to be deployed
  2. Then PCM can be deployed
  3. vCMTS application can be deployed
  4. pktgen applications can be deployed

Collectd

vCMTS requires a collectd socket to provide metrics; in order to retrieve these metrics, we are creating a collectd instance that will provide the socket to vCMTS, and a collectd exporter that will expose the collected metrics on port 9103, so OpenShift Prometheus instance can scrape them.

But default, OpenShift Prometheus instance is only scraping metrics from the platform (i.e. openshift-* namespace). In order for OpenShift Prometheus to scrape user projects metrics we need to enable "user workload metrics".

oc apply -f config/monitoring/prometheus-enable-user-workload.yaml

Once done, we can deploy collectd and collectd-exporter, along with OpenShift Prometheus configuration ServiceMonitor

oc create -f deploy/tools/collectd.yaml

Grafana

Load vCMTS Grafana Dashboards

oc kustomize config/monitoring/dashboards | oc apply -f -

Create Grafana Instance

oc create -f config/monitoring/grafana.yaml

Configure Grafna to use OpenShift thanos as proxy data source to retrieve prometheus data.

oc adm policy add-cluster-role-to-user cluster-monitoring-view -z grafana-serviceaccount -n vcmts-build
BEARER_TOKEN=$(oc serviceaccounts get-token grafana-serviceaccount -n vcmts-build)

echo "apiVersion: integreatly.org/v1alpha1
kind: GrafanaDataSource
metadata:
  name: prometheus-grafanadatasource
  namespace: vcmts-build
spec:
  datasources:
    - access: proxy
      editable: true
      isDefault: true
      jsonData:
        httpHeaderName1: 'Authorization'
        timeInterval: 5s
        tlsSkipVerify: true
      name: prometheus
      secureJsonData:
        httpHeaderValue1: 'Bearer ${BEARER_TOKEN}'
      type: prometheus
      url: 'https://thanos-querier.openshift-monitoring.svc.cluster.local:9091'
  name: prometheus-grafanadatasource.yaml" | oc apply -f -

Processor Counter Monitor

In order to measure the aggregate memory bandwidth consumed by the cores, PCM tool is used, and it relies on the collectd socket to send the memory bandwidth utilization data.

As such, deploy PCM after collectd has been deployed

oc create -f deploy/tools/pcm.yaml

Deploy the application

Now that the monitoring stack is up and running, you can deploy the applications, that will automatically start.

Start by deploying the vCMTS application

helm install vcmtsd deploy/applications/vcmtsd -n vcmts-build

Then deploy the pktgen application

helm install pktgen deploy/applications/pktgen -n vcmts-build

Generate traffic

Finally, in order to control Pktgen traffic generation, helper scripts have been build and packaged into a pod.

To get started, deploy the pod

oc apply -f deploy/tools/pktgen-config-pod.yaml

Use to following command to start the traffic generator

oc get pods -n vcmts-build -l app=pktgen-helper -o name | xargs -I {} /bin/bash -c 'oc rsh -n vcmts-build {} /opt/scripts/start.sh'

Use to following command to set traffic rate.

The first argument is either 0 or 1, respectively idenfitying upstream and downstream traffic. The seconf argument is the rate the apply.

Here is an example for applying 2.3G of traffic upstream and 7.3G of traffic downstream.

oc get pods -n vcmts-build -l app=pktgen-helper -o name | xargs -I {} /bin/bash -c 'oc rsh -n vcmts-build {} /opt/scripts/set.sh 0 2.3'
oc get pods -n vcmts-build -l app=pktgen-helper -o name | xargs -I {} /bin/bash -c 'oc rsh -n vcmts-build {} /opt/scripts/set.sh 1 7.3'

If you have QAT enabled for some of the SG, then you need to use the below command to set the upstream or downstream traffic

oc get pods -n vcmts-build -l app=pktgen-helper -o name | xargs -I {} /bin/bash -c 'oc rsh -n vcmts-build {} /opt/scripts/set-qat.sh 0 2.3'
oc get pods -n vcmts-build -l app=pktgen-helper -o name | xargs -I {} /bin/bash -c 'oc rsh -n vcmts-build {} /opt/scripts/set-qat.sh 1 9'