tplink-safeloader: fix C7v5 factory flashing from vendor fw > v1.1.x
Browse files Browse the repository at this point in the history
Currently it's not possible to flash factory images on devices shipped
with vendor firmware versions 1.1.0 Build 20201120 rel. 50406 (published
2020-12-22):

 (curFw_ver, newFw_ver) == (1.1, 1.0) [NM_Error](nm_checkSoftVer) 00848: Firmwave not supports, check failed.
 [NM_Error](nm_checkUpdateContent) 01084: software version dismatched
 [NM_Error](nm_buildUpgradeStruct) 01188: checkUpdateContent failed.

They've even following note in release notes:

 Note: You will be unable to downgrade to the previous firmware version
       after updating this firmware.

This version check in vendor firmware is implemented in
/usr/bin/nvrammanager binary likely as following C code[1]:

 sscanf(buf, "%d.%d.%*s",&upd_fw_major, &upd_fw_minor);
 ...
 if (((int)upd_fw_major < (int)cur_fw_major) ||
     ((ret = 1, cur_fw_major == upd_fw_major && (upd_fw_minor < (int)cur_fw_minor)))) {
       ret = 0;
       printf("[NM_Error](%s) %05d: Firmwave not supports, check failed.\r\n\r\n","nm_checkSoftVer" ,0x350);
 }
 ...
 return ret;

So in order to fix this and make it future proof it should be enough to
ship our factory firmware images with major version 7 (lucky number).

Tested on latest firmware version 1.1.2 Build 20210125 rel.37999:

 Firmwave supports, check OK.
  (curFw_ver, newFw_ver) == (1.1, 7.0) check firmware ok!

Flashing back to vendor firmware
c7v5_us-up-ver1-1-2-P1[20210125-rel37999]_2021-01-25_10.33.55.bin works
as well:

 U-Boot 1.1.4-gbec22107-dirty (Nov 18 2020 - 18:19:12)
 ...
 Firmware downloaded... filesize = 0xeeae77 fileaddr = 0x80060000.
 Firmware Recovery file length : 15642231
 Firmware process id 2.
 handle_fw_cloud 146
 Image verify OK!
 Firmware file Verify ok!
 product-info:product_name:Archer C7
 product_ver:5.0.0
 special_id:55530000
 [Error]sysmgr_cfg_checkSupportList(): 1023 @ specialId 45550000 NOT Match.
 Firmware supports, check OK.
 Firmware Recovery check ok!

1. https://gist.github.com/ynezz/2e0583647d863386a66c3d231541b6d1

Signed-off-by: Petr Štetiar <ynezz@true.cz>
(cherry picked from commit e6d6637)
Signed-off-by: Petr Štetiar <ynezz@true.cz>
  • Loading branch information
ynezz committed May 6, 2021
1 parent 1b5a45a commit a2728a8
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion tools/firmware-utils/src/tplink-safeloader.c
Expand Up @@ -938,7 +938,7 @@ static struct device_info boards[] = {
"{product_name:Archer C7,product_ver:5.0.0,special_id:4B520000}\n",

.support_trail = '\x00',
.soft_ver = "soft_ver:1.0.0\n",
.soft_ver = "soft_ver:7.0.0\n",

/* We're using a dynamic kernel/rootfs split here */
.partitions = {
Expand Down