Close websocket with 1011 on internal error (1006 is a client-only code) #112

Merged
merged 1 commit into from
Jul 8, 2023

Conversation

samsamoa
Copy link
Contributor

See https://www.rfc-editor.org/rfc/rfc6455.html ->

1006 is a reserved value and MUST NOT be set as a status code in a
      Close control frame by an endpoint.

This issue is exacerbated by what may be a bug in wsproto, where a 1006 code is turned into a 1000 (success) code.

@samsamoa
Copy link
Contributor Author

Related wsproto issue: python-hyper/wsproto#182

@pgjones
Copy link
Owner

pgjones commented Jul 8, 2023

Looks good thanks. I'll take a look at wsproto shortly.