Notifications
You must be signed in to change notification settings - Fork 5
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
RCT/YJ/Updating report file names #1365
Conversation
) | ||
|
||
def create_data(self, context, data=None): |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Deleted since this can be integrated into data_items
.
@@ -1,11 +1,9 @@ | |||
import json | |||
from copy import deepcopy | |||
from datetime import datetime |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Deleted b/c it's not in use.
fail_line = f"|Fail|{self.ruleset_outcome['All'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['Envelope'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['Lighting'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['Receptacles'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['Transformers'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['HVAC-HotWaterSide'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['HVAC-ChilledWaterSide'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['HVAC-AirSide'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['HVAC-General'][RCTOutcomeLabel.FAILED]}|{self.ruleset_outcome['HVAC-Baseline'][RCTOutcomeLabel.FAILED]}|" | ||
not_applicable_line = f"|Not Applicable|{self.ruleset_outcome['All'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['Envelope'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['Lighting'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['Receptacles'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['Transformers'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['HVAC-HotWaterSide'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['HVAC-ChilledWaterSide'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['HVAC-AirSide'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['HVAC-General'][RCTOutcomeLabel.NOT_APPLICABLE]}|{self.ruleset_outcome['HVAC-Baseline'][RCTOutcomeLabel.NOT_APPLICABLE]}|" | ||
undetermined_line = f"|Undetermined (manual review)|{self.ruleset_outcome['All'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['Envelope'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['Lighting'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['Receptacles'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['Transformers'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['HVAC-HotWaterSide'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['HVAC-ChilledWaterSide'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['HVAC-AirSide'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['HVAC-General'][RCTOutcomeLabel.UNDETERMINED]}|{self.ruleset_outcome['HVAC-Baseline'][RCTOutcomeLabel.UNDETERMINED]}|" | ||
( |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
This part was simplified with the private function (_generate_line
) because as we have more and more sections, it's hard to list all the column values.
"5": "Envelope", | ||
"6": "Lighting", | ||
"10": "HVAC General", |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@weilixu Both sections 10 and 19 have the same section name. Should we update one of these section names?
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@yunjoonjung-PNNL There are several things happening here. Section 19 and Section 10 are sort of mixed. I know there are some discussions on moving the unmet load hours check to section 10 but we currently put this on hold until everything becomes more stable.
A rule renumbering will be conducted, we just need to wait longer to get everything sort out first.
For now, using HVAC - General
for section 19 and HVAC General
for section 10.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Sounds great! I'll move the rules when they are reorganized.
"5": "Envelope", | ||
"6": "Lighting", | ||
"10": "HVAC General", |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
@yunjoonjung-PNNL There are several things happening here. Section 19 and Section 10 are sort of mixed. I know there are some discussions on moving the unmet load hours check to section 10 but we currently put this on hold until everything becomes more stable.
A rule renumbering will be conducted, we just need to wait longer to get everything sort out first.
For now, using HVAC - General
for section 19 and HVAC General
for section 10.
This PR mainly addresses to save the report name with its class name. Further, the PR addresses a few bug fixes/updates. Thanks!