Reset settings for spiral vase mode is inconsistent #7146

Closed
mroek opened this issue Oct 21, 2021 · 2 comments
Closed

Reset settings for spiral vase mode is inconsistent #7146

mroek opened this issue Oct 21, 2021 · 2 comments

Comments

@mroek
Copy link

mroek commented Oct 21, 2021

Version

Version 2.4.0-alpha3+win64

Steps:

  1. Enable spiral vase mode from a normal settings profile
  2. Click OK in the dialog box that asks if Prusaslicer should change other settings in order to use spiral vase mode
  3. Click the back arrow in the top menu line, which should reset all settings in that option group, including spiral vase

Instead of just resetting the settings, the dialog box from 2) above pops back up again, which I think it shouldn't do, as the reset command should turn off spiral vase mode (and not ask again if you want to enable it). It is simple enough to just answer "No" in this dialog box to get the expected result, but the dialog box should not have popped up again. It is simply confusing.

This is just a very minor bug, and one that is easy to work around, but you might want to change this behaviour.

@bubnikv
Copy link
Collaborator

bubnikv commented Dec 11, 2021

Fixed in the upcoming PrusaSlicer 2.4.0-beta4.

@bubnikv bubnikv closed this as completed Dec 11, 2021
@mroek
Copy link
Author

mroek commented Dec 11, 2021

Great, thanks.