Timouts... #61
Comments
Hi Tom |
Hallo Timmo, |
Hi tom,
Weiterlaufen tut es… ich beobachte es mal.
Viele Grüße - Timmo
Timmo Sturm
Wittelsbacherstr. 8
85622 Feldkirchen
+49 151 402 71 711
Thomas Heiny ***@***.***> schrieb am So. 14. Apr. 2024 um
13:53:
… Hallo Timmo,
die Timeouts kommen beim Zugriff auf das Hauskraftwerk.
Mit v3.19 habe ich eine Änderung gebracht, die bei "Max. buffer size
exceeded" dazu führt, dass das Programm danach weiterläuft... allerdings
ohne es testen zu können.
Sonnige Grüße
Thomas
—
Reply to this email directly, view it on GitHub
<#61 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AD4FS666TYWASHF5FC7SIADY5JU27AVCNFSM6AAAAABGGEAI7CVHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDANJUGAZDGMZQGI>
.
You are receiving this because you authored the thread.Message ID:
***@***.***>
|
Hallo Timmo, |
Hi Tom, können wir gerne machen, allerdings dann erstmal nativ ohne docker…
Viele Grüße - Timmo
|
Genau, ganz ohne Docker... mit Kompilieren und so :-) curl https://raw.githubusercontent.com/pvtom/rscp2mqtt/dev/RscpMqttMain.cpp |
Hi Tom, pi@sturmserver:/opt/rscp2mqtt $ ./rscp2mqtt -v [2024-04-15 21:53:27] pid=1144717 ppid=1135969 RscpMqttMain.cpp(540) Topic >e3dc/battery/state< unused? Payload is empty |
Hallo Timmo, |
cool freut mich! |
Die Lösung steht jetzt mit v3.20 zur Verfügung. |
Hi Tom,
probiere mal wieder... bin jetzt erstmal ohne Docker unterwegs. Funktioniert soweit, ich bekomme nur ab und an Timeouts.. kannst Du sagen, was den Timeout erzeugt (e3dc, influx etc?)
pi@sturmserver:/opt/rscp2mqtt $ ./rscp2mqtt
rscp2mqtt [v3.19]
E3DC system >192.168.178.58:5033< user: >Timmo.Sturm<
MQTT broker >localhost:1883< qos = >0< retain = >false< client id >✗< prefix >e3dc<
Fetching data every 10 seconds.
Requesting PVI ✓ | PM (0) | DCB ✓ (1 battery string) | Wallbox (0) ✓ | Autorefresh ✗
Log level = 1
Stdout to terminal
[2024-04-14 13:12:23] pid=1067620 ppid=982363 RscpMqttMain.cpp(2717) Connecting to server 192.168.178.58:5033
[2024-04-14 13:12:23] pid=1067620 ppid=982363 RscpMqttMain.cpp(2724) Success: E3DC connected.
[2024-04-14 13:12:23] pid=1067620 ppid=982363 RscpMqttMain.cpp(1688) RSCP authentication level 10
[2024-04-14 13:12:23] pid=1067620 ppid=982363 RscpMqttMain.cpp(2221) Connecting to broker localhost:1883
[2024-04-14 13:12:23] pid=1067620 ppid=982363 RscpMqttMain.cpp(2233) Success: MQTT broker connected.
[2024-04-14 13:12:23] pid=1067620 ppid=982363 RscpMqttMain.cpp(345) MQTT: starting listener loop
[2024-04-14 13:12:24] pid=1067620 ppid=982363 RscpMqttMain.cpp(1806) Error: Container 0x02840000 Tag 0x02000060 received error code 6.
[2024-04-14 13:12:24] pid=1067620 ppid=982363 RscpMqttMain.cpp(1806) Error: Container 0x02840000 Tag 0x02000070 received error code 6.
[2024-04-14 13:12:24] pid=1067620 ppid=982363 RscpMqttMain.cpp(1806) Error: Container 0x02840000 Tag 0x02000080 received error code 6.
[2024-04-14 13:12:28] pid=1067620 ppid=982363 RscpMqttMain.cpp(2100) Error: Response receive timeout (retry)
[2024-04-14 13:12:32] pid=1067620 ppid=982363 RscpMqttMain.cpp(2100) Error: Response receive timeout (retry)
meine config:
#-E3DC Access
#--IP address and port of your home power station
E3DC_IP=192.168.178.58
E3DC_PORT=5033
#--your E3/DC web account and the RSCP/AES password configured in the device (Issue #31)
E3DC_USER={private}
E3DC_PASSWORD={private}
E3DC_AES_PASSWORD={private}
#-MQTT Broker
#--Name or IP address and port of your MQTT broker
MQTT_HOST=localhost
MQTT_PORT=1883
#--MQTT parameters
MQTT_CLIENT_ID=
MQTT_QOS=0
MQTT_RETAIN=false
#--MQTT authentication if necessary set MQTT_AUTH=true and enter user and password
MQTT_AUTH=false
MQTT_USER=
MQTT_PASSWORD=
#-System
#--cycle interval in seconds (max 300 seconds)
INTERVAL=10
#--log level, set "1" to get detailled logging
LOG_LEVEL=1
#--log files
LOGFILE=/tmp/rscp2mqtt.log
TOPIC_LOG_FILE=/tmp/rscp2mqtt.history
#--dry run
DISABLE_MQTT_PUBLISH=false
#--set power mode
AUTO_REFRESH=false
#--Start of Operation
HISTORY_START_YEAR=2017
#--Request daily historical values
DAILY_VALUES=true
#--Publish statistic values
STATISTIC_VALUES=true
#-MQTT Topics
#--Topic prefix (max 24 characters), default is e3dc
PREFIX=e3dc
#-Power Meter
#--PM_INDEX can be set multiple times if several power meters exist, default is 0
#--PM_EXTERN=true has the same effect as PM_INDEX=6 (6 for S10 Mini, compatibilty with previous releases)
PM_EXTERN=false
PM_INDEX=0
PM_REQUESTS=true
#-Photovoltaic Inverter
PVI_REQUESTS=true
#--Number of PVI strings/trackers (disables the auto detection)
PVI_TRACKER=2
#-Battery Settings
#--Number of Battery Strings, default is 1
BATTERY_STRINGS=1
#--Battery Modules
DCB_REQUESTS=true
#-Battery SOC limiter
#SOC_LIMITER=true
#LIMIT_CHARGE_SOC=0
#LIMIT_DISCHARGE_SOC=0
#LIMIT_CHARGE_DURABLE=false
#LIMIT_DISCHARGE_DURABLE=false
#LIMIT_DISCHARGE_BY_HOME_POWER=0
#-Wallbox Support for the wallbox with the specified index
#--only one WB_INDEX entry is supported, default is 0
WALLBOX=true
WB_INDEX=0
#-Forced Topics
#--will be published with every cycle
FORCE_PUB=e3dc/[a-z]+/power
#FORCE_PUB=e3dc/pvi/.*/string_[1,2]
FORCE_PUB=e3dc/solar/energy
FORCE_PUB=e3dc/battery/soc
FORCE_PUB=e3dc/battery/energy/discharge
FORCE_PUB=e3dc/battery/energy/charge
FORCE_PUB=e3dc/home/energy
FORCE_PUB=e3dc/grid/energy/in
FORCE_PUB=e3dc/grid/energy/out
#-Topic Logging
#--logging to extra log file configured by TOPIC_LOG_FILE
#TOPIC_LOG=e3dc/history/.*
#TOPIC_LOG=e3dc/battery/dcb/[1-4]/soh
#TOPIC_LOG=e3dc/system/software
The text was updated successfully, but these errors were encountered: