H2Spec correctly flags that we don't really do any validation of settings values:
6.5.2. Defined SETTINGS Parameters
× SETTINGS_ENABLE_PUSH (0x2): Sends the value other than 0 or 1
- The endpoint MUST respond with a connection error of type PROTOCOL_ERROR.
Expected: GOAWAY frame (ErrorCode: PROTOCOL_ERROR)
Connection close
Actual: SETTINGS frame (Length: 0, Flags: 1)
× SETTINGS_INITIAL_WINDOW_SIZE (0x4): Sends the value above the maximum flow control window size
- The endpoint MUST respond with a connection error of type FLOW_CONTROL_ERROR.
Expected: GOAWAY frame (ErrorCode: FLOW_CONTROL_ERROR)
Connection close
Actual: SETTINGS frame (Length: 0, Flags: 1)
× SETTINGS_MAX_FRAME_SIZE (0x5): Sends the value below the initial value
- The endpoint MUST respond with a connection error of type PROTOCOL_ERROR.
Expected: GOAWAY frame (ErrorCode: PROTOCOL_ERROR)
Connection close
Actual: SETTINGS frame (Length: 0, Flags: 1)
× SETTINGS_MAX_FRAME_SIZE (0x5): Sends the value above the maximum allowed frame size
- The endpoint MUST respond with a connection error of type PROTOCOL_ERROR.
Expected: GOAWAY frame (ErrorCode: PROTOCOL_ERROR)
Connection close
Actual: SETTINGS frame (Length: 0, Flags: 1)