List of confirmed working air con units
kecsger edited this page May 14, 2025
·
184 revisions
Please update this if you use the Faikin and find it works with your model.
The code should work with a BRP069B41
, BRP069C41
, or similar WiFi modules work connecting to S21
or X50
ports.
Mostly models will be S21
unless otherwise specified. Please do add more detail if you can, or ask in a discussion.
Current Amazon listing (UK) is the model that supports 5V working on Tx and Rx.
See Wiring.
Model | Description | Notes |
---|---|---|
FTXSxxLVMA | S21 Type A cable | |
FTXVxxLVMA | XL series | S21 Type A cable |
FTKFxxTVMA | Lite cooling only | S403 Type D cable |
FDYQxxxL(A/B)1 | Ducted | X50A Type C cable |
FDYQNxxxLAV1 | Ducted | X50A Type C cable |
FTX(N)xxNMVJU | Aurora (Canada) | S403 Type E cable |
FTXxxAXVJU | 19 Series (Canada) | S21 Type A cable |
FCAxxxCVMA | Ceiling cassette type | X50A Type F cable (Molex micro-lock socket) |
FCAxxCAVMA | Ceiling cassette type | X50A Type F cable (Molex micro-lock socket) |
ATXN25NV1B9 | Daikin 'Siesta' Wall-mount | CN_WIRED connector |
ATXN35NV1B9 | Daikin 'Siesta' Wall-mount | CN_WIRED connector |
FTXJxxTVMAx | Zena splits | S21 Type B cable (smaller PAP S21 socket) |
FDYA160AV19 | premium inverter ducted | Uses X50A port, Type C cable |
FDYAN160AV1 | inverter ducted (Australian) | Uses X50A port, Type F cable |
FTKSxxLVMA | L-series cooling only | S21 Typa A cable |
FTKSxxKVMA | L-series | S21 Typa A cable |
FTXVxxWVMA | Cora | Standard S21 Typa A cable. Also known to use Type D and Type E S403 cable |
FTXMxxQVMA | Cora | Standard S21 Typa A cable |
FTXMxxUVMA | Alira | S21 Type A cable, may also use Type D |
FTXMxxWVMA | Alira X split system | S21 Type B cable (smaller PAP S21 socket) |
FTXMxxW2VMA | Alira X split system | S21 Type B cable (smaller PAP S21 socket) guide here |
FTXB12BXVJU | Entra wall mount | S21, lead not pre-installed, fits inside the case |
FTXJ25MV1BS | Wall mount | Fits inside the case, lead seems to be pre-installed |
FTXM20A2V1B | Wall mount | Fits inside the case |
FTXM25F3V1B9 | Ducted | Needs cable, uses X50 port |
FTXS12LVJU | Wall-Mount | |
FTXS09LVJU | Wall-Mount | |
FTXS24LVJU | Wall-Mount | |
FTXS25BVMA | Wall-Mount | S21, powerful not working |
FTXS25DAVMW | Wall-Mount | S21, powerful not working #329 |
FTXS35D2VMW | Wall-Mount | S21, powerful not working #329 |
FTXS35DAVMW | Wall-Mount | S21, powerful not working #329 |
FTXSxxKVMA | Wall-Mount | Standard S21 Typa A cable, fits inside the case |
FTXS35K2V1B | Wall-Mount | S21, fits inside the case |
FTXS60BVMB | Wall-Mount | S21, fits inside the case with 20cm patch cable. Uses JST EH 2.5mm Pitch 5P connector (Aliexpress > Same direction - 20cm - 5P). Use a multimeter to figure out where pins 4 (14.4V) and 5 (GND) are and make sure all wires are 1:1, as even when choosing "Same direction" some wires can still come in reverse order. The best way to ensure you're connecting the plug correctly is to ensure pin 4 (14.4V) is connected to pin 4 on the Faikin board which has a "12V" mark on back. You will need to use an X-acto to carefully lift the lever on the connector to passthrough the cables via the shielded electronics box in order to install the Faikin board outside it - you can also use this opportunity to swap the red and black wires to match pins 4 and 5, respectively. This way the red wire will carry 14.4V and the black wire will be GND, instead of being the green and yellow ones. |
FTXS71JVMA | Wall-Mount | S21, fits inside the case |
FTXS35G2V1B | Wall-Mount | S21, powerful not working #329 |
FTX24UVJU | Wall-Mount | S21, fits inside the case |
FTXS15WVJU9 | Wall-Mount | S21, fits inside the case |
FTXS09WVJU9 | Wall-Mount | S21, fits inside the case |
CTXS07LVJU | Wall-Mount | |
CTXS07WVJU9 | Wall-Mount | S21, fits inside the case |
CTXS09HVJU | Wall mount | S21 connector present, lead not pre-installed |
ADEA71A2VEB | Sky Air, Ducted | Needs cable, uses X35A (power supply) and X50A (communication) ports |
FTXM20R2V1B | Perfera wall-mounted | Working with S21 socket - see #49 |
FTXF20D5V1B | Sensira wall-mounted | Working with ESP8266 port |
FTXF35D5V1B | Sensira wall-mounted | |
FTXF42D5V1B | Sensira wall-mounted | |
FVXG25K2V1B | Nexura Series Floor Standing Unit | S21, No radiant heating control (as with official controller) |
FVXG35K2V1B | Nexura Series Floor Standing Unit | S21, No radiant heating control (as with official controller) |
FDXS25EAVMB | Concealed ceiling unit | S21, Older unit (2006) |
FDXS50CVMB | Slim Concealed Ceiling Unit | S21, Older unit (2008) |
FTXJ20A2V1BW | Daikin Emura 3 | Photos - bought an EKRS21 cable, had to join s21 male-to-male - More photos to open the device |
FTXJ35A2V1BB, FTXJ25A2V1BB | Daikin Emura 3 | See this Topic Take care with PIN assignment |
FTXSxxG2V1B | Daikin Perfera | S21 socket with no 5V power (only 14.5). TTL 3.3V compatible. Does not allow: Powerful and Eco modes control and reporting, Power consumption, FAN quiet mode, presence sensor. Fan, Mode, Power, H and V swing, Ext-Int-Coil temp, compressor idle state working |
FTXPxxMxxxxx | Daikin Comfora | S21 (no lead installed), does not work with 3.3V signals. Works with 5V signal or open drain signal. See #62 |
FTXS50JVMA | 2010 wall-mount | S21 |
FTX25K2V1B | Needs newest model, with 5V Tx working | |
CTXMxxRxV1B | Perfera 2022 | new (smaller) S21 port (PAP-05V-S), original Daikin adapter cable to old S21 P/N: EKRS21, all 5 cables need to be connected, usable place for original wifi module 45mm X 36mm (cut PCB to size) below metal shield (pictures) |
FTXMxxRxV1B | Perfera 2022 | new (smaller) S21 port (PAP-05V-S), original Daikin adapter cable to old S21 P/N: EKRS21, all 5 cables need to be connected, usable place for original wifi module 45mm X 36mm (cut PCB to size) below metal shield (pictures) |
FTXS35CVMB8 | Old 2006 wall mount model | connection via S21 port, all seems to be working except for "Powerful" mode. Home Leave, Silent and Sensor are not available options |
FTXS35GVMA | 2010 Wall-Mount | S21 port. Fits perfectly inside the case. |
FNA35A2VEB9 | FAN-A9 Concealed floor standing unit | S21 port, ducted outside of unit |
FBA71BVLT | Ceiling(TW) | X50A with X35 |
CDXS50DVMT | Ceiling(TW) | Original S21 adapter (JST EKR-5) |
FTXS25DVMT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
FTXV**SVLT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
FTXM**RVLT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
FDXV**RVLT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
FTXM**VVLT | Wall-Mount(TW) | Mini S21 port (JST PAP-05V-S) |
FTHF40VVLT | Wall-Mount(TW) | S403 Connector (JST PAP-10V-S) |
FTHF20RVLT | Wall-Mount(TW) | S403 Connector (JST PAP-10V-S) |
FTKS35DVMT | Wall-Mount | Old Model(2005) |
FBQ50C7VEB | Concealed Ceiling Unit | Uses X50 port |
FTXS71LVMA | S21 Connector present, I used 4 F-F jumper leads between main board and faikin. | |
FTXA42A2V1 | Stylish 2022 | S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module |
FTXTA30C2V1BW | Stylish 2025 | New S21 PA Connector with pitch 2.0mm. Needs JST-EH5 to PA (JST-PAP-05V-S) cable |
CTXM15R | Perfera 2021 | S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module |
FTXM20R | Perfera 2021 | S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module |
FTXR42EV | Wall-Mount | S21 Connector. Everything working correctly except specific humidity modes and outside air renewal of Ururu Sarara models. |
FTXR12WVJUW9 | Wall-Mount Emura Series | S21 connector. Cable was factory provided. Module easily fits in mounting location for OEM module. |
FTXS25LVMA | S21 Connector present, used 5x F-F dupont jumper cables | |
FTXA42C2V1BW | Wall Mount | S21 Connector present, used 5x F-F dupont jumper cables and one EKRS21 as the EKRS21 is male and faikin board is male. Took original wifi board out and put faikin in its little hole. Fits very nicely. Had to guess which way round the pinout was. Didn't blow it up the wrong way round, so all good! Probably works with all FTXA**C2V1BW range. All features work. |
FTXNG09AXVJU | S21 Connector present, joined two s21 (EH) male-to-male cables | |
FVXMxxA2V1B | Perfera Floor Standing Unit | New S21 PA Connector with pitch 2.0mm. Needs JST-EH5 to PA (JST-PAP-05V-S) cable. Fits in place of the original WiFi module, but also works in parallel of it. |
FVXMxxA3V1B | Perfera Floor Standing Unit | New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable (same as new Perfera Wall-Mount). Fits in place of the original WiFi module. Most things working. Not working: Heat+, Floor Warming mode. The Led/Eye brightness can be changed setting noled to false. |
FTKS35CVMB8 | Wall-Mount | Old Model(2004) S21 Connector 5 pin, reversed connector orientation. |
FTXS40JVLT | Wall-Mount | S21 |
FTXM50PVMA | Wall-Mount | S21 Connector present, used 5x F-F dupont jumper cables |
FTXM46RVMZ | Wall-Mount | S403 Connector present, requires 5V signals, used 5x F-F dupont jumper cables then connected to header |
CTXA15AW | Stylish Wall-Mount | New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable |
FTXAxxC2V1Bx | Stylish Wall-Mount | S21 (new style JST PAP-05V-S connector so requires a cable with that or the EKRS21 to convert it back to JST EH-5; pinout is the same either way). Built-in wifi has its own connector, not S21, so I left that alone. I used EHR-5, BEH-001T-P0.6, PAP-05V-S, SPHD-001T-P0.5 and 22 AUD multicore to make a cable (crimp tool required). Ideal cable length is 35-37cm. There's space underneath the end wiring panel to tape the Faikin to. Can alternatively use cable that comes with original wifi BRP069C4x |
FTXMxxA2V1B | Perfera 2024 | S21 Connector present |
FTXMxxA5V1B | Perfera 2024 | S21 with 2.0mm JST-PA Connector present, space on the right side near the thermistor. |
ATX35JV1B | Daikin 'Siesta' Wall-mount | No native S21, used a KRP980B1 wired remote interface board. |
FTXS35K3V1B | Wall-mount | Native S21, used an ESP C3 supermini with a transformer from 14Vcc to 5Vcc and a logic TTL converter for Rx and Tx. |
FTKU35BV1MF | Daikin Deluxe (Wall-Mount) | S21 Connector present, used 30cm 5pin JST EHR 2.5mm to Dupont cable. Powerful, Eco+ mode not support |
ATXD25A | Siesta Wall-Mount | Used S403 Connector with a pin-to-pin custom cable |
ATXF25E | Siesta Wall-Mount | Used S403 Connector with a pin-to-pin custom cable |
FTXMxxR2V1B | Perfera Wall-Mount | S21 Connector on upper PCB at the upper side - isolated from mains - PAP connector - 5V supply voltage available and working fine with a ESP32 WROOM |
FTXM35R | Perfera Wall-Mount | Used the new S21 JST-PA Connector with 2.0mm pitch, see pictures for details. |
FTXV71WVMA | Daikin Cora Reverse Cycle Split System (Australian model) | Direct to S403 connector, no mods needed, 2mm JST Shaved down fits. High Voltage Caution required. May also use Type A S21. Also known to use Type D and Type E S403 cable |
ATXC25CV1B | Wall-mount | Native S21, used an ESP C6 with a bump converter from 14Vcc to 5Vcc and a logic TTL converter for Rx and Tx. Not all queries working - getting NAK from S21 for RH/RI/Ra/RL queries |
FTXF35C5V1B | Wall-mount 2021/06 | Native S21, the supplied connector did not work. But a set of female to female dupont cables did the job. |
FTXG26EV1BW | Wall-Mount | Native S21, the supplied connector did work but a female to female cables required. |
FTXG35LV1BW | Wall-Mount | Native S21, cable included and fits inside dedicated compartment |
FTXF35E5V1B | Sensira Wall-Mounted | S403 connector |
CTXM25RVMA, CTXM35RVMA | Australian indoor wall mounted 2.5/3.5kW Cora unit for R32 multi split system | S403 connector with XAP-10V-1 connector. Very likely will work on CT(X/K)M(20/25/35/42)RVMA |
CTXM85RVMA | NZ indoor wall mounted | S21 connector |
CTXM20RVMA, CTXM60RVMA, CTXM50RVMA | Australian indoor wall mounted 6kW Cora unit for R32 multi split system | S403 connector with slightly misfitting JST PAP-10V-S connector. Very likely will work also on CT(X/K)M(60/71)RVMA. CTXM50RVMA basic controls only work not econo, powerful, quiet etc.. |
FTXS42JV1B | Wall-Mounted | S21 connector - Tested with ESP8266 fork |
FTXC35BV1B | Wall-Mount | Model 2019, S21, used original Daikin-Cables from BRP069B41 (4 leads) |
ATXF35D5V1B | Wall-Mount | Model 2022, S21, used original Daikin-Cables from BRP069B41 (4 leads) |
FX60GV1B | Wall-Mounted | S21 connector - Tested with ESP8266 fork |
FTXB12AXVJU | Wall-Mount (US) | CN_WIRED connector |
FTX12AXVJU | Wall-Mount | S21 (Type A - Fits Jumper Cables) |
ATXS25G | Wall-Mounted | S21 connector |
FTM50JV14 | Wall-Mounted | S21 socket present, used JST XH2.54MM, Length 20CM, 5P cable, Powerful mode does not work, all other modes ok. |
FTM35JV14 | Wall-Mounted | S21 socket present, used JST XH2.54MM, Length 20CM, 5P cable, Powerful mode not working, all other modes ok. |
FTC35NV14 | Wall-Mounted | S403 socket present, used THIS cable (Type E), all modes working. |
Any not working - please advise. | ||
FBQ71C7VEB | Ducted | Has X50 port, but port is disabled - Tried with ESP8266 port - DOES NOT WORK |
FTXV35UVMA | Wall-Mount | Native S21. Econo, Powerful, Stream/filter, Sensor mode, Comfort mode, Quiet outdoor all toggle off. |
FTXV60WVMA | Wall-Mount | Native S21. Econo, Powerful, Stream/filter, Sensor mode, Comfort mode, Quiet outdoor all toggle off. Also known to use Type D and Type E S403 cable. |
FTXS20D3VMW | Wall-Mount 2008 model | Native S21 (cable not provided), Powerful mode does not work, all other modes ok. |
FTXG35EV1BW | Wall-Mount 2007 model | Native S21 (cable not provided), Powerful mode does not work, all other modes ok. |
FDXM60F9 | Slim Ducted | Uses X50 port, requires a cable. Used the one from the previous offical Wifi Unit. |
GTHT50UV16VZ | Wall-Mounted (Kenya) | S403 connector |
FVXMxxFV1B9 | Perfera Wall-Mount | (old) S21 Connector - note that it's a slightly bigger connector |
FTXS25K3V1B | Wall Mounted | Used S403 Connector with a pin-to-pin custom cable |
FTXS60GV1B | Wall Mounted | S21, powerful not working #329 |
FTXS20G2V1B | Wall Mounted | S21, powerful not working #329 |
FDXM25F9/FDXM35F9 | Ducted | Needs cable, uses X50A port + X35A for powering the Faikin |
FTKG60TV | Wall-Mount (India) | S403 connector. Used a JST-XH (10-pin) to Dupont cable. Cable alterations - (1) Removed Pin 2,3,7,8,9,10 (2) Cut off protruding clips |
FTYN60GV1A | Wall-Mount | S21 Type A 2.5mm JST-EH |
FWT04GATNMV1 | Daikin Fan Coil | CN_WIRED connector |
FWT04CATNMV1 | Fan Coil (wall mounted) | CN_WIRED connector, see this comment for pinout (the connector on the board is a JST 2.0 PH 5-pin male connector) |
FWT02GT | Daikin Fan Coil | CN_WIR connector interface (slightly different to CN_WIRED) |
ADEQ100C2VEB | Ducted | X50A + X35A |
ZFAG60A | Cassette | NOT TESTED. This unit is compatible with BRP069C81, which uses X50A + X35A headers. Any feedback would be appreciated |