noise navigator

This Matlab code can be used to calculate the noise navigator shown in these articles:

R.J.M. Navest, A. Andreychenko, J.J.W. Lagendijk, and C.A.T. van den Berg, “Prospective Respiration Detection in Magnetic Resonance Imaging by a Non-Interfering Noise Navigator“, IEEE Transactions on Medical Imaging 2018;37(8):1751-1760, doi:10.1109/TMI.2018.2808699;

R.J.M. Navest, S. Mandija, A. Andreychenko, A.J.E. Raaijmakers, J.J.W. Lagendijk, and C.A.T. van den Berg, “Understanding the physical relations governing the noise navigator“, Magnetic Resonance in Medicine 2019;82(6):2236-2247, doi:10.1002/mrm.27906;

R.J.M. Navest, S. Mandija, T. Bruijnen, B. Stemkens, R.H.N Tijssen, A. Andrey- chenko, J.J.W. Lagendijk, and C.A.T. van den Berg, “The noise navigator: a sur- rogate for respiratory-correlated 4D-MRI for motion characterization in radiotherapy“, Physics in Medicine & Biology 2020;65(1):01NT02, doi:10.1088/13616560/ab5c62;


The "demo_noise_navigator" script shows a respiratory motion detection example for a 2D balanced steady-state free precession cine MRI acquisition acquired at a 1.5T hybrid MRI-linac system. Due to size limitations, the data was uploaded for the individual RF receive channels separately and combined again in the script.

Function overview in order of appearance

  1. noiseCoVar_git requires the raw MRI (i.e. k-space) data in the format [kx, profiles, channels], where the profiles are in chronological acquisition order. The second input needed is the FOV for the MRI data that contains anatomy (the bore has a diameter of 700 mm and thus everything outside 720 mm is considered thermal noise as there cannot be any anatomy). The output is the thermal noise (co)variance calculated per profile, corresponding time vector and the number of thermal noise samples per profile used to calculate the thermal noise (co)variance. alt text Notice that the respiratory modulation can already be observed in the anterior channels. alt text The fifth principal component resembles the respiratory motion best.
  2. fourierCoeff calculates the frequency spectrum of the input data. alt text The respiratory frequency component is clearest in the fifth principal component.
  3. Kalman_IEEE_legacy applies the Kalman filter described in the IEEE article mentioned above to the thermal noise variance combined for all RF receive channels.
  4. MovingAverage_legacy applies a moving average filter with a certain window length to the thermal noise variance combined for all RF receive channels. The final result showing the unfiltered, Kalman-filtered and moving average filtered noise navigator is shown in the figure below. alt text

The Kalman and moving average filter both reveal the respiratory imprint in the chosen principal component.


For questions or suggestions feel free to send me a message at robin.navest@gmail.com

About

a motion detection method for MRI