26 changes: 26 additions & 0 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -155,6 +155,32 @@ You can obtain Energy monitoring (voltage, current) in two different ways:
unit_of_measurement: 'W'
```

# Climates

There are a multitude of Tuya based climates out there, both heaters,
thermostats and ACs. The all seems to be integrated in different ways and it's
hard to find a common DP mapping. Below are a table of DP to product mapping
which are currently seen working. Use it as a guide for your own mapping and
please contribute to the list if you have the possibility.

| DP | Moes BHT 002 | Qlima WMS S + SC52 (AB;AF) | Avatto |
|-----|---------------------------------------------------------|---------------------------------------------------------|--------------------------------------------|
| 1 | ID: On/Off<br>{true, false} | ID: On/Off<br>{true, false} | ID: On/Off<br>{true, false} |
| 2 | Target temperature<br>Integer, scaling: 0.5 | Target temperature<br>Integer, scaling 1 | Target temperature<br>Integer, scaling 1 |
| 3 | Current temperature<br>Integer, scaling: 0.5 | Current temperature<br>Integer, scaling: 1 | Current temperature<br>Integer, scaling: 1 |
| 4 | Mode<br>{0, 1} | Mode<br>{"hot", "wind", "wet", "cold", "auto"} | ? |
| 5 | Eco mode<br>? | Fan mode<br>{"strong", "high", "middle", "low", "auto"} | ? |
| 15 | Not supported | Supported, unknown<br>{true, false} | ? |
| 19 | Not supported | Temperature unit<br>{"c", "f"} | ? |
| 23 | Not supported | Supported, unknown<br>Integer, eg. 68 | ? |
| 24 | Not supported | Supported, unknown<br>Integer, eg. 64 | ? |
| 101 | Not supported | Outdoor temperature<br>Integer. Scaling: 1 | ? |
| 102 | Temperature of external sensor<br>Integer, scaling: 0.5 | Supported, unknown<br>Integer, eg. 34 | ? |
| 104 | Supported, unknown<br>{true, false(?)} | Not supported | ? |

[Moes BHT 002](https://community.home-assistant.io/t/moes-bht-002-thermostat-local-control-tuya-based/151953/47)
[Avatto thermostat](https://pl.aliexpress.com/item/1005001605377377.html?gatewayAdapt=glo2pol)

# Debugging

Whenever you write a bug report, it helps tremendously if you include debug logs directly (otherwise we will just ask for them and it will take longer). So please enable debug logs like this and include them in your issue:
Expand Down
15 changes: 8 additions & 7 deletions custom_components/localtuya/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -139,15 +139,16 @@ def _device_discovered(device):
)
new_data[ATTR_UPDATED_AT] = str(int(time.time() * 1000))
hass.config_entries.async_update_entry(entry, data=new_data)
device = hass.data[DOMAIN][TUYA_DEVICES][device_id]
if not device.connected:
device.async_connect()

elif device_id in hass.data[DOMAIN][TUYA_DEVICES]:
# _LOGGER.debug("Device %s found with IP %s", device_id, device_ip)
_LOGGER.debug("Device %s found with IP %s", device_id, device_ip)

device = hass.data[DOMAIN][TUYA_DEVICES].get(device_id)
if not device:
_LOGGER.warning(f"Could not find device for device_id {device_id}")
elif not device.connected:
device.async_connect()

device = hass.data[DOMAIN][TUYA_DEVICES][device_id]
if not device.connected:
device.async_connect()

def _shutdown(event):
"""Clean up resources when shutting down."""
Expand Down

0 comments on commit e0f74d8