6 changes: 6 additions & 0 deletions miio/airpurifier_miot.py
Expand Up @@ -46,6 +46,7 @@
# AQI (siid=13)
"purify_volume": {"siid": 13, "piid": 1},
"average_aqi": {"siid": 13, "piid": 2},
"aqi_realtime_update_duration": {"siid": 13, "piid": 9},
# RFID (siid=14)
"filter_rfid_tag": {"siid": 14, "piid": 1},
"filter_rfid_product_id": {"siid": 14, "piid": 3},
Expand Down Expand Up @@ -401,6 +402,11 @@ class AirPurifierMiot(BasicAirPurifierMiot):
)
def status(self) -> AirPurifierMiotStatus:
"""Retrieve properties."""
# Some devices update the aqi information only every 30min.
# This forces the device to poll the sensor for 5 seconds,
# so that we get always the most recent values. See #1281.
if self.model == "zhimi.airpurifier.mb3":
self.set_property("aqi_realtime_update_duration", 5)

return AirPurifierMiotStatus(
{
Expand Down