These are the specification for the reduction of HRS observations for the pipeline. This includes data quality measurements as well as reducing and distribution calibration and observational data.

Bias Reductions

  • Median Combine biases
  • Upload background levels to sdb
  • Upload overscan level to sdb
  • Copy master bias to calibration directory

Flat Reductions

  • Subtract master bias
  • Median Combine flats
  • Upload background levels to sdb
  • Upload overscan level to sdb
  • Create Order frame
  • Upload order positions to sdb
  • Copy master flat to calibration directory

Arc Reductions

  • Subtract master bias
  • Median Combine arcs
  • Extract object fiber
  • Extract target fiber
  • Upload background levels to sdb
  • Upload overscan level to sdb
  • Identify/match lines in each order
  • Upload match lines to sdb
  • Calculate 2D Wavelength solution
  • Copyw wavelength to calibration directory

Science Reductions

  • Subtract master bias
  • Apply flat correction
  • Upload background levels to sdb
  • Upload overscan level to sdb
  • Extract object fiber
  • Extract target fiber
  • Normalize extracted spectra
  • Subtract sky from extracted spectra
  • Stitch spctra together
  • Apply Wavelength solution
  • Vacuum to air correction
  • heliocentric correction

Radial Velocity Reductions

Spectrophotometric Standard reductions

Questions/Improvements

  • Is subtracting off the master bias sufficient to correct overscan levels?
  • The extraction needs to be improved.