Teralight - Small service for controlling an Axpert inverter via Serial commands.

##Axpert Commands and examples

Command Description
Q1 Undocumented command:
LocalInverterStatus (seconds from absorb), ParaExistInfo (seconds from end of Float), SccOkFlag, AllowSccOnFlag, ChargeAverageCurrent, SCC PWM Temperature, Inverter Temperature, Battery Temperature, Transformer Temperature, GPDAT, FanLockStatus, FanPWMDuty, FanPWM, SCCChargePowerWatts, ParaWarning, SYNFreq, InverterChargeStatus
QPI Device protocol ID inquiry
QID The device serial number inquiry
QVFW Main CPU Firmware version inquiry
QVFW2 Another CPU Firmware version inquiry
QFLAG Device flag status inquiry
QPIGS Device general status parameters inquiry:
GridVoltage, GridFrequency, OutputVoltage, OutputFrequency, OutputApparentPower, OutputActivePower, OutputLoadPercent, BusVoltage, BatteryVoltage, BatteryChargingCurrent, BatteryCapacity, InverterHeatSinkTemperature, PV-InputCurrentForBattery, PV-InputVoltage, BatteryVoltageFromSCC, BatteryDischargeCurrent, DeviceStatus,
QMOD Device mode inquiry P: PowerOnMode, S: StandbyMode, L: LineMode, B: BatteryMode, F: FaultMode, H: PowerSavingMode
QPIWS Device warning status inquiry:
Reserved, InverterFault, BusOver, BusUnder, BusSoftFail, LineFail, OPVShort, InverterVoltageTooLow, InverterVoltageTooHIGH, OverTemperature, FanLocked, BatteryVoltageHigh, BatteryLowAlarm, Reserved, ButteryUnderShutdown, Reserved, OverLoad, EEPROMFault, InverterSoftFail, SelfTestFail, OPDCVoltageOver, BatOpen, CurrentSensorFail, BatteryShort, PowerLimit, PVVoltageHigh, MPPTOverloadFault, MPPTOverloadWarning, BatteryTooLowToCharge, Reserved, Reserved
QDI The default setting value information
QMCHGCR Enquiry selectable value about max charging current
QMUCHGCR Enquiry selectable value about max utility charging current
QBOOT Enquiry DSP has bootstrap or not
QOPM Enquiry output mode
QPIRI Device rating information inquiry - nefunguje
QPGS0 Parallel information inquiry:
TheParallelNumber, SerialNumber, WorkMode, FaultCode, GridVoltage, GridFrequency, OutputVoltage, OutputFrequency, OutputAparentPower, OutputActivePower, LoadPercentage, BatteryVoltage, BatteryChargingCurrent, BatteryCapacity, PV-InputVoltage, TotalChargingCurrent, Total-AC-OutputApparentPower, Total-AC-OutputActivePower, Total-AC-OutputPercentage, InverterStatus, OutputMode, ChargerSourcePriority, MaxChargeCurrent, MaxChargerRange, Max-AC-ChargerCurrent, PV-InputCurrentForBattery, BatteryDischargeCurrent
QBV Compensated Voltage, SoC
PEXXX Setting some status enable
PDXXX Setting some status disable
PF Setting control parameter to default value
FXX Setting device output rating frequency
POP02 set to SBU
POP01 set to Solar First
POP00 Set to UTILITY
PBCVXX_X Set battery re-charge voltage
PBDVXX_X Set battery re-discharge voltage
PCP00 Setting device charger priority: Utility First
PCP01 Setting device charger priority: Solar First
PCP02 Setting device charger priority: Solar and Utility
PGRXX Setting device grid working range
PBTXX Setting battery type
PSDVXX_X Setting battery cut-off voltage
PCVVXX_X Setting battery C.V. charging voltage
PBFTXX_X Setting battery float charging voltage
PPVOCKCX Setting PV OK condition
PSPBX Setting solar power balance
MCHGC0XX Setting max charging Current M XX
MUCHGC002 Setting utility max charging current 0 02
MUCHGC010 Setting utility max charging current 0 10
MUCHGC020 Setting utility max charging current 0 20
MUCHGC030 Setting utility max charging current 0 30
POPMMX Set output mode M 0:single, 1: parrallel, 2: PH1, 3: PH2, 4: PH3