CAN/WiFi Gateway for Stiebel Eltron Heatpumps

Gateway to communicate with Stiebel Eltron heat pump controllers via an HTTP-based API. It communicates with the heatpump controller using the native, proprietary CAN protocol and provides the features and data through a more integration friendly HTTP API to the outside. Developed for deployment on an ESP8266 board with a separate CAN adapter/bridge.

For a schematic and PCB layout to build a device able to run this go to https://github.com/simonlmn/can-wifi-gateway-hardware.

Support

If you want to support this project, you can:

  • use it and provide feedback
  • fix bugs
  • develop improvements or new features
  • Donate

Similar projects and references

Of course, this is not the only or even the first attempt to reverse engineer the CAN bus protocol of Stiebel Eltron devices and to build a custom gateway to integrate these into various smart home solutions or similar things. What follows is a list in no particular order of websites, blog posts or forum discussions which in one way or another helped to build this solution:

Documentation

Compatibility

The protocol and, most importantly, the value definitions have been successfully tested with the following heatpumps so far:

  • Stiebel Eltron LWZ 5 S Plus

The protocol implementation is also working with other models based on the same/similar hardware from Stiebel Eltron and also Tecalor. However, for other models, the devices running on the bus may be completely different and using different IDs for the various values and parameters.

Integration / APIs

See API documentation for details on the available protocols, endpoints and data schemas.

Setup Guide

Pre-condition: you have built the necessary hardware (e.g. based on https://github.com/simonlmn/can-wifi-gateway-hardware) and have uploaded the wifi-gateway sketch to the ESP8266 NodeMCU board and the serial-can-bridge to a the Arduino Nano.

Step 1: Connect the gateway to your heatpump's CAN (aka BUS) terminals, which normally includes both the CAN H and L lines as well as the ground and +12V supply lines.

Note

Where you find these terminals depends on the heatpump model and setup. As CAN is a bus system, you can basically connect to it at either end or between existing nodes. For example, directly at the heatpump controller or at/after a WPM or room control unit. Bus termination must be set accordingly at the ends only or otherwise the entire communication can break down!

Warning

Connecting a device not officially approved by the manufacturer to your heatpump may void its warranty! It is possible for the gateway to interfere with the normal communication necessary for your heatpump to work correctly, which may lead to, for example, decreased performance, outages and temporary or permanent damage.

Caution

Connecting to the bus may require to remove a protective cover of the heatpump to access the terminals. While the CAN terminals are low-voltage/low-power, the mains voltage, high power terminals are usually close by and are also exposed.

Working close to exposed mains level electrical installation is dangerous and can be lethal! It is important to follow certain safety protocols, which usually include turning off the respective breaker(s) and testing/ensuring that power is actually turned off and stays turned off while working on the equipment. Doing any kind of work on mains level installation may also be outright illegal at your location.

Step 2: When the gateway has power, it will start up into config mode as it does not have a WiFi configuration yet. It starts its own WiFi access point and will appear as can-wifi-gw-<chip-id>. The blue LED on the ESP8266 will blink slowly in this mode.

Step 3: Connect to the WiFi. It should automatically open a captive portal to configure the WiFi to connect to (e.g. your home network).

If the captive portal does not automatically show up, you can manually open a browser and go to 192.168.4.1.

WiFi Configuration

Step 4: Save the configuration, the gateway will automatically restart and will try to connect to the configured WiFi from now on.

If the connection fails (e.g. the entered WiFi password is wrong), it will start in config mode again so you can fix the configuration (this will again be indicated by the slow blinking blue LED). It will automatically restart every 5 minutes though in order to prevent staying in config mode if there was only a temporary connection problem.

Step 5: Find out which IP address was assigned to the gateway. This is typically shown on the administration interface of your WiFi router. The gateway will have the hostname can-wifi-gw-<chip-id>.

Step 6: Open the address in a browser (HTTP, not HTTPS!) and the administration UI will show up. The first screen shows the general status and diagnostic information. Especially the logs are useful to diagnose problems.

Status Screen

Step 7: Go to the "Configuration" screen and set the base settings to be able to interact with your heatpump:

Configuration Screen

  • "Device type": should be set to "Display", although probably anything will work as long as it is unique in combination with the address on the bus.

  • "Device address": this must be a number between 0 and 127 and allows to distinguish between multiple devices of the same type.

    For "displays", the official FES units use index 1 to 4 which translates into device addresses 30 to 33. As long as you configure the gateway to use an unused device type and address combination, it should work.

  • "Enable write access": if you want to set parameters or in general control your heatpump this must be enabled. Otherwise, this could be left disabled to prevent accidentally overwriting parameters.

  • "Data capture mode": should be set to "Configured".

    It controls which data is actually captured from the heatpump and can be changed to:

    • "None": collect no data at all
    • "Configured": collect only data which explicitly has been configured (in the section at the bottom of the "Configuration" screen).
    • "Defined": collect also data for which a definition is available (as shown on the "Definitions" screen). It will only capture these additional datapoints when some other components on the bus are sending/requesting them (e.g. when using the built-in display to view/change some parameters).
    • "Any": collect any data even when there is no definition. In this case, only raw values will be available for those, as the units and conversion function is not known.
  • "CAN mode": should be set to "Normal".

    It controls how the CAN module is set up:

    • "Normal": connect to the bus and allow receiving and sending messages.

    • "ListenOnly": connect to the bus and allow receiving messages only. This actually prevents any messages from being sent, so the gateway will only capture data which is actively sent by the heatpump controller or display units (as the gateway cannot send any request messages this way).

      Note: This is different from "Enable write access", as that setting only prevents writing to parameters, but still allows the gateway to request data from the heatpump controller.

    • "LoopBack": do not connect to the actual bus, but set up the module in "loop back" mode. Any message sent by the gateway will be returned as a received message. This is only useful for development purposes.

Tip

To chose a unique and yet unused device address, you can see which devices have been seen on the bus by going to the "Status" screen to the "Devices" section at the bottom.

Step 8: Save the base settings which will be immediately applied. You can check the logs on the "Status" screen if the settings were applied and if the CAN module was successfully set up (there should be a message like "SETUP OK 96 8 8 8 8 4 1 20000 64")

Step 9: To set up which datapoints and parameters are going to be captured and available for writing by the gateway, go to the "Data configuration" section on the "Configuration" screen and add the desired IDs.

Some IDs require to set the "Source Address" or the "Mode":

  • "Source Address": some sources can appear multiple times in the system and must be addressed individually. The only known case is the heating circuits: there are potentially two heating circuits which both may have the same datapoint/parameter IDs. To tell them apart, the first one has address 1 and the second one has address 2.

  • "Mode": if the selected ID is a writable parameter, you can decide if you

    • only want to "Subscribe" to it, meaning that it won't actually be available for writing (e.g. you only want to know the current value and see when it is changed through other means).
    • want it to be "Writable" only, meaning that it will be available for writing, but changes which are not communicated on the bus are not captured (some parameters are re-set/changed by the heatpump controller internally).
    • want it to be "Both".

There is also the option to load a file to configure many data entries at once.

Note

It is not possible to define datapoints or parameters at run-time. The list of currently known and configurable values is defined at compile time and can be found in src/wifi-gateway/ValueDefinitions.h. A future implementation could of course provide fully run-time configurable definitions.

Step 10: After some data is configured, go to "Data" screen and see if/how the values are captured.

After this initial setup, the gateway should be ready to be integrated into, for example, the home automation system of your choice. There is also basic support for MQTT, which can also be congiured via the UI.