Skip to content

sparkeh/dell-idrac-fan-control

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

2 Commits
 
 
 
 
 
 
 
 

Repository files navigation

Dell iDRAC fan control with IPMI

This script came from the need to keep a dell T430 server quiet enough in a home office. The room average temps are about 22 to 25 degrees C and CPU avarages at 30 to 34 degrees C with the fan at 16%. No major issues observed and the server is quiet enough and not as loud as a desktop PC.

Your mileage may vary.

Presently I'm running this script every 5 minutes with a crontab on Ubuntu 18.04 - (see below for cron code)

Setting the MAX_TEMP variable will ensure that should the system get too hot, dynamic fan mode will engage. However you will need to use crontab for this. Adjust temp to your liking.

Installation

These are for Ubuntu

  • You'll need to install ipmitool
sudo apt install ipmitool
  • git clone this repo
  • Append to existing crontab, or make a new one:
*/5 * * * * /bin/bash /srv/dell-idrac-fan-control/fan-control.sh

Overall this does the job for what I need to do. It could potentially be extended to leverage SNMP values on temperature or SNMP traps to change fan speed. It should be noted that while you can change the speed % of the fan on the iDRAC GUI, this method works for any fan percentage setting.

Tested on iDRAC ver 3.30.30.30

About

Dell iDRAC Fan Control

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

 
 
 

Languages