Sunsynk Docs apps.yaml and automations #1331

Open
tmh88 opened this issue Jul 26, 2024 · 6 comments
Open

Sunsynk Docs apps.yaml and automations #1331

tmh88 opened this issue Jul 26, 2024 · 6 comments
Labels
documentation Improvements or additions to documentation fixed

Comments

@tmh88
Copy link

tmh88 commented Jul 26, 2024

Below is the code for the my app.yaml and automations used to integrate my Sunsynk 8.8Kw ECCO inverter, hopefully it helps others. Thanks to @springfall2008 for the code modifications along the way.

apps.yaml

---
pred_bat:
  module: predbat
  class: PredBat

  # Sets the prefix for all created entities in HA - only change if you want to run more than once instance
  prefix: predbat

  # Timezone to work in
  timezone: Europe/London

  # If you are using Predbat outside of HA then set the HA URL and Key (long lived access token here)
  #ha_url: 'http://homeassistant.local:8123'
  #ha_key: 'xxx'

  # Currency, symbol for main currency second symbol for 1/100s e.g. $ c or £ p or e c
  currency_symbols:
    - '£'
    - 'p'

  # Number of threads to use in plan calculation
  # Can be auto for automatic, 0 for off or values 1-N for a fixed number
  threads: auto

  # Sets the maximum period of zero load before the gap is filled, default 30 minutes
  # To disable set it to 1440
  load_filter_threshold: 30

  #
  # Sensors, more than one can be specified and they will be summed up automatically
  #
  # For two inverters the load today would normally be the master load sensor only (to cover the entire house)
  # If you have three phase and one inverter per phase then you would need three load sensors
  #
  # For pv_today if you have multiple solar inverter inputs then you should include one entry for each inverter
  #
  load_today:
    - sensor.sunsynk_load_power_daily_2 # load_power_daily_kWh
  import_today:
    - sensor.smart_meter_electricity_import_today # electric_import_daily_kWh
  export_today:
    - sensor.smart_meter_electricity_total_export_daily # electric_export_daily_kWh
  pv_today:
    - sensor.sunsynk_total_pv_power_daily

  # Load forecast can be used to add to the historical load data (heat-pump)
  # To link to Predheat
  # Data must be in the format of 'last_updated' timestamp and 'energy' for incrementing kWh
  #load_forecast:
  #  - predheat.heat_energy$external
  #
  # Controls/status - must by 1 per inverter
  #
  num_inverters: 1
  inverter_type: SK


  # **** Start of Outputs to Sunsynk Inverter ****

  charge_start_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode" # Inverter work mode
    option: "Limited to Home"

  charge_stop_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode" # Inverter work mode
    option: "Limited to Home"

  discharge_start_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode"  # Inverter work mode
    option: "Selling First"   

  timed_charge_current:
    - number.sunsynk_battery_max_charge_current # Inverter battery max charge setting in A

  timed_discharge_current:
    - number.sunsynk_battery_max_discharge_current # Inverter battery max discharge setting in A

  charge_limit:
    - number.sunsynk_set_soc_timezone1 # Inverter SOC time slot1
  # added to test need to add atuomation to copy to sunsynk timeslots

  # **** End of Outputs to Sunsynk Inverter **** 


  # Run balance inverters every N seconds (0=disabled) - only for multi-inverter
  balance_inverters_seconds: 0
  #

  # Custom sensors to get the BMS charge/discharge limit, based on inverter size (8000kW, BMS reported limit, and inverter set limit)
  inverter_limit_charge:
    - sensor.sunsynk_battery_max_charge_rate # {{ [8000,[states('input_number.sunsynk_battery_max_charge_current_limit')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  inverter_limit_discharge:
    - sensor.sunsynk_battery_max_discharge_rate # {{ [8000,[states('input_number.sunsynk_battery_max_discharge_current_limit')|int, states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  # calculations to tell predbat the actual charge/discharge power of the inverter
  charge_rate:
    - sensor.sunsynk_charge_rate_calc # {{ [8000,[states('input_number.test_sunsynk_battery_max_charge_current')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  discharge_rate:
    - sensor.sunsynk_discharge_rate_calc # {{ [8000,[states('input_number.test_sunsynk_battery_max_discharge_current')|int,states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  battery_rate_max:
    - 8000  # The maximum rate of the battery charge/discharge in watts **required to lift the 2600w default limit**

  battery_voltage:
    - sensor.sunsynk_battery_voltage

  battery_power:
    - sensor.sunsynk_battery_output_power #in watts

  pv_power:
    - sensor.sunsynk_total_solar #in watts

  load_power:
    - sensor.sunsynk_load_power #in watts

  soc_kw:
    - sensor.bcc_battery_soc_kwh #in kWh

  soc_max:
    - input_number.battery_cappacity #in kWh

  battery_min_soc:
    - sensor.sunsynk_battery_capacity_shutdown #in %

#  reserve:
#    - sensor.sunsynk_battery_capacity_shutdown #in % (belive this is disabled for Sunsynk)

#  inverter_mode:
#    - select.givtcp_{geserial}_mode
#  inverter_time:
#    - sensor.givtcp_{geserial}_invertor_time
#  charge_start_time:
#    - select.givtcp_{geserial}_charge_start_time_slot_1
#  charge_end_time:
#    - select.givtcp_{geserial}_charge_end_time_slot_1

#  scheduled_charge_enable:
#    - switch.givtcp_{geserial}_enable_charge_schedule
#  scheduled_discharge_enable:
#    - switch.givtcp_{geserial}_enable_discharge_schedule
#  discharge_start_time:
#    - select.givtcp_{geserial}_discharge_start_time_slot_1
#  discharge_end_time:
#    - select.givtcp_{geserial}_discharge_end_time_slot_1

  # Pause mode is not supported by all firmware's and will be ignored if not present
#  pause_mode:
#   - select.givtcp_{geserial}_battery_pause_mode

  # Not all firmwares support pause start/end time, delete these if not supported
  # to avoid spurious writes/warnings
#  pause_start_time:
#   - select.givtcp_{geserial}_battery_pause_start_time_slot
#  pause_end_time:
#   - select.givtcp_{geserial}_battery_pause_end_time_slot

  # Inverter max AC limit (one per inverter). E.g for a 3.6kw inverter set to 3600
  # If you have a second inverter for PV only please add the two values together
  inverter_limit:
    - 8000 # change to inveter size in W

  # Export limit is a software limit set on your inverter that prevents exporting above a given level
  # When enabled Predbat will model this limit
  #export_limit:
  # - 3600
  # - 3600

  # Some inverters don't turn off when the rate is set to 0, still charge or discharge at around 200w
  # The value can be set here in watts to model this (doesn't change operation)
  #inverter_battery_rate_min:
  #  - 200

  # Workaround to limit the maximum reserve setting, some inverters won't allow 100% to be set
  # Comment out if your inverter allows 100%
#  inverter_reserve_max : 98

  # Some batteries tail off their charge rate at high soc%
  # enter the charging curve here as a % of the max charge rate for each soc percentage.
  # the default is 1.0 (full power)
  # The example below is from GE 9.5kwh battery with latest firmware and gen1 inverter
  #
  # Predbat can compute this curve automatically if you have enough data, restart the add-on and look in the logfile for the data
  # once set here Predbat will no longer re-compute the curve.
  # Can also be set to 'auto' to just use the calculation curve, not recommended if you are using low power charging mode.
  #battery_charge_power_curve:
  #  91 : 0.91
  #  92 : 0.81
  #  93 : 0.71
  #  94 : 0.62
  #  95 : 0.52
  #  96 : 0.43
  #  97 : 0.33
  #  98 : 0.24
  #  99 : 0.24
  #  100 : 0.24
  #battery_discharge_power_curve:
  #  4 : 1.0

  # Inverter clock skew in minutes, e.g. 1 means it's 1 minute fast and -1 is 1 minute slow
  # Separate start and end options are applied to the start and end time windows, mostly as you want to start late (not early) and finish early (not late)
  # Separate discharge skew for discharge windows only
  inverter_clock_skew_start: 0
  inverter_clock_skew_end: 0
  inverter_clock_skew_discharge_start: 0
  inverter_clock_skew_discharge_end: 0

  # Clock skew adjusts the Appdaemon time
  # This is the time that Predbat takes actions like starting discharge/charging
  # Only use this for workarounds if your inverter time is correct but Predbat is somehow wrong (AppDaemon issue)
  # 1 means add 1 minute to AppDaemon time, -1 takes it away
  clock_skew: 0

  # Solcast cloud interface, set this or the local interface below
  #solcast_host: 'https://api.solcast.com.au/'
  #solcast_api_key: 'xxxx'
  #solcast_poll_hours: 8

  # Set these to match solcast sensor names if not using the cloud interface
  # The regular expression (re:) makes the solcast bit optional
  # If these don't match find your own names in Home Assistant
  pv_forecast_today: re:(sensor.(solcast_|)(pv_forecast_|)forecast_today)
  pv_forecast_tomorrow: re:(sensor.(solcast_|)(pv_forecast_|)forecast_tomorrow)
  pv_forecast_d3: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_3|d3))
  pv_forecast_d4: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_4|d4))

  # car_charging_energy defines an incrementing sensor which measures the charge added to your car
  # is used for car_charging_hold feature to filter out car charging from the previous load data
  # Automatically set to detect Wallbox and Zappi, if it doesn't match manually enter your sensor name
  # Also adjust car_charging_energy_scale if it's not in kwH to fix the units
#  car_charging_energy: 're:(sensor.myenergi_zappi_[0-9a-z]+_charge_added_session|sensor.wallbox_portal_added_energy)'

  # Defines the number of cars modelled by the system, set to 0 for no car
  num_cars: 0

  # car_charging_planned is set to a sensor which when positive indicates the car will charged in the upcoming low rate slots
  # This should not be needed if you use Intelligent Octopus slots which will take priority if enabled
  # The list of possible values is in car_charging_planned_response
  # Auto matches Zappi and Wallbox, or change it for your own
  # One entry per car
#  car_charging_planned:
#    - 're:(sensor.wallbox_portal_status_description|sensor.myenergi_zappi_[0-9a-z]+_plug_status)'

#  car_charging_planned_response:
#    - 'yes'
#    - 'on'
#    - 'true'
#    - 'connected'
#    - 'ev connected'
#    - 'charging'
#    - 'paused'
#    - 'waiting for car demand'
#    - 'waiting for ev'
#    - 'scheduled'
#    - 'enabled'
#    - 'latched'
#    - 'locked'
#    - 'plugged in'

  # In some cases car planning is difficult (e.g. Ohme with Intelligent doesn't report slots)
  # The car charging now can be set to a sensor to indicate the car is charging and to plan
  # for it to charge during this 30 minute slot
  #car_charging_now:
  #  - off

  # Positive responses for car_charging_now
#  car_charging_now_response:
#    - 'yes'
#    - 'on'
#    - 'true'

  # To make planned car charging more accurate, either using car_charging_planned or the Octopus Energy plugin,
  # specify your battery size in kwh, charge limit % and current car battery soc % sensors/values.
  # If you have Intelligent Octopus the battery size and limit will be extracted from the Octopus Energy plugin directly.
  # Set the car SOC% if you have it to give an accurate forecast of the cars battery levels.
  # One entry per car if you have multiple cars.
  #car_charging_battery_size:
  #  - 75
  #car_charging_limit:
  #  - 're:number.tsunami_charge_limit'
  #car_charging_soc:
  #  - 're:sensor.tsunami_battery'

  # One per car, when true only one car can charge at once, when False multiple cars can charge at once
  #car_charging_exclusive:
  #  - True

  # If you have Octopus intelligent, enable the intelligent slot information to add to pricing
  # Will automatically disable if not found, or comment out to disable fully
  # When enabled it overrides the 'car_charging_planned' feature and predict the car charging based on the intelligent plan (unless octopus intelligent charging is False)
  # This matches either the intelligent slot from the Octopus Plugin or from the Intelligent plugin
  #octopus_intelligent_slot: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_intelligent_dispatching)'
  #octopus_ready_time: 're:(time.octopus_energy([0-9a-z_]+|)_intelligent_ready_time)'
  #octopus_charge_limit: 're:(number.octopus_energy([0-9a-z_]+|)_intelligent_charge_limit)'
  # Example alternative configuration for Ohme integration release >=v0.6.1
  #octopus_intelligent_slot: 'binary_sensor.ohme_slot_active'
  #octopus_ready_time: 'time.ohme_target_time'
  #octopus_charge_limit: 'number.ohme_target_percent'

  # Carbon Intensity data from National grid
  carbon_intensity: 're:(sensor.carbon_intensity_uk)'

  # Octopus saving session points to the saving session Sensor in the Octopus plugin, when enabled saving sessions will be at the assumed
  # Rate is read automatically from the add-in and converted to pence using the conversion rate below (default is 8)
  octopus_saving_session: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_saving_session(s|))'
  octopus_saving_session_octopoints_per_penny: 8

  # Energy rates
  # Please set one of these three, if multiple are set then Octopus is used first, second rates_import/rates_export and latest basic metric

  # Set import and export entity to point to the Octopus Energy plugin import and export sensors
  # automatically matches your meter number assuming you have only one (no need to edit the below)
  # Will be ignored if you don't have the sensor but will error if you do have one and it's incorrect
  # NOTE: To get detailed energy rates you need to go in and manually enable the following events in HA
  #       event.octopus_energy_electricity_xxxxxxxx_previous_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_current_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_next_day_rates
  # and if you have export enable:
  #       event.octopus_energy_electricity_xxxxxxxx_export_previous_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_export_current_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_export_next_day_rates
  # Predbat will automatically find the event. entities from the link below to the sensors
  metric_octopus_import: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_rate)'
  metric_octopus_export: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_export_current_rate)'

  # Standing charge in pounds, can be set to a sensor or manually entered (e.g. 0.50 is 50p)
  # The default below will pick up the standing charge from the Octopus Plugin
  # The standing charge only impacts the cost graphs and doesn't change the way Predbat plans
  # If you don't want to show the standing charge then just delete this line or set to zero
  metric_standing_charge: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_standing_charge)'

  # Or set your actual rates across time for import and export
  # If start/end is missing it's assumed to be a fixed rate
  # Gaps are filled with zero rate
  #rates_import:
  #  -  start: "00:30:00"
  #     end: "04:30:00"
  #     rate: 7.5
  #  -  start: "04:30:00"
  #     end: "00:30:00"
  #     rate: 40.0
  #
  #rates_export:
  #  -  rate: 4.2

  # Can be used instead of the plugin to get import rates directly online
  # Overrides metric_octopus_import and rates_import
  # rates_import_octopus_url : "https://api.octopus.energy/v1/products/FLUX-IMPORT-23-02-14/electricity-tariffs/E-1R-FLUX-IMPORT-23-02-14-A/standard-unit-rates"
  # rates_import_octopus_url : "https://api.octopus.energy/v1/products/AGILE-FLEX-BB-23-02-08/electricity-tariffs/E-1R-AGILE-FLEX-BB-23-02-08-A/standard-unit-rates"

  # Overrides metric_octopus_export and rates_export
  # rates_export_octopus_url: "https://api.octopus.energy/v1/products/FLUX-EXPORT-BB-23-02-14/electricity-tariffs/E-1R-FLUX-EXPORT-BB-23-02-14-A/standard-unit-rates"
  # rates_export_octopus_url: "https://api.octopus.energy/v1/products/AGILE-OUTGOING-BB-23-02-28/electricity-tariffs/E-1R-AGILE-OUTGOING-BB-23-02-28-A/standard-unit-rates/"
  # rates_export_octopus_url: "https://api.octopus.energy/v1/products/OUTGOING-FIX-12M-BB-23-02-09/electricity-tariffs/E-1R-OUTGOING-FIX-12M-BB-23-02-09-A/standard-unit-rates/"

  # Import rates can be overridden with rate_import_override
  # Export rates can be overridden with rate_export_override
  # Use the same format as above, but a date can be included if it just applies for a set day (e.g. Octopus power ups)
  # This will override even the Octopus plugin rates if enabled
  #
  #rates_import_override:
  # -  date: '2023-09-10'
  #    start: '14:00:00'
  #    end: '14:30:00'
  #    rate: 112
  #    load_scaling: 0.8

  # For pv estimate, leave blank for central estimate, or add 10 for 10% curve (worst case) or 90 or 90% curve (best case)
  # If you use 10 then disable pv_metric10_weight below
  # pv_estimate: 10

  # Days previous is the number of days back to find historical load data
  # Recommended is 7 to capture day of the week but 1 can also be used
  # if you have more history you could use 7 and 14 (in a list) but the standard data in HA only lasts 10 days
  days_previous:
    - 7
    - 14

  # Days previous weight can be used to control the weighting of the previous load points, the values are multiplied by their
  # weights and then divided through by the total weight. E.g. if you used 1 and 0.5 then the first value would have 2/3rd of the weight and the second 1/3rd
  # Include one value for each days_previous value, each weighting on a separate line.
  # If any days_previous's that are not given a weighting they will assume a default weighting of 1.
  days_previous_weight:
    - 1

  # Number of hours forward to forecast, best left as-is unless you have specific reason
  forecast_hours: 48

  # Specify the devices that notifies are sent to, the default is 'notify' which goes to all
  #notify_devices:
  #  - mobile_app_treforsiphone12_2

  # Battery scaling makes the battery smaller (e.g. 0.9) or bigger than its reported
  # If you have an 80% DoD battery that falsely reports it's kwh then set it to 0.8 to report the real figures
  # One per inverter
  battery_scaling:
    - 1.0

  # Can be used to scale import and export data, used for workarounds
  import_export_scaling: 1.0

  # Export triggers:
  # For each trigger give a name, the minutes of export needed and the energy required in that time
  # Multiple triggers can be set at once so in total you could use too much energy if all run
  # Creates an entity called 'binary_sensor.predbat_export_trigger_<name>' which will be turned On when the condition is valid
  # connect this to your automation to start whatever you want to trigger
  export_triggers:
    - name: 'large'
      minutes: 60
      energy: 1.0
    - name: 'small'
      minutes: 15
      energy: 0.25

  # If you have a sensor that gives the energy consumed by your solar diverter then add it here
  # this will make the predictions more accurate. It should be an incrementing sensor, it can reset at midnight or not
  # It's assumed to be in Kwh but scaling can be applied if need be
  #iboost_energy_today: 'sensor.xxxxx'
  #iboost_energy_scaling: 1.0
  # Gas rates for comparison
  #metric_octopus_gas: 're:(sensor.(octopus_energy_|)gas_[0-9a-z]+_[0-9a-z]+_current_rate)'

  # Nordpool market energy rates
  #futurerate_url: 'https://www.nordpoolgroup.com/api/marketdata/page/325?currency=GBP'
  #futurerate_adjust_import: True
  #futurerate_adjust_export: False
  #futurerate_peak_start: "16:00:00"
  #futurerate_peak_end: "19:00:00"
  #futurerate_peak_premium_import: 14
  #futurerate_peak_premium_export: 6.5

  # Watch list, a list of sensors to watch for changes and then update the plan if they change
  # This is useful for things like the Octopus Intelligent Slot sensor so that the plan update as soon as you plugin in
  # Only uncomment the items you actually have set up above in apps.yaml, of course you can add your own as well
  # Note those using +[] are lists that are appended to this list, whereas {} items are single items only
  #watch_list:
  #  - '{octopus_intelligent_slot}'
  #  - '{octopus_ready_time}'
  #  - '{octopus_charge_limit}'
  #  - '{octopus_saving_session}'
  #  - '+[car_charging_planned]'
  #  - '+[car_charging_soc]'
  #  - '{car_charging_now}'

Automations

Predbat Charge / Discharge Control

alias: Predbat Charge / Discharge Control
description: ""
trigger:
  - platform: state
    entity_id:
      - binary_sensor.predbat_charging
    to: "on"
    id: predbat_charge_on
  - platform: state
    entity_id:
      - binary_sensor.predbat_charging
    to: "off"
    id: predbat_charge_off
  - platform: state
    entity_id:
      - binary_sensor.predbat_discharging
    to: "on"
    id: predbat_discharge_on
  - platform: state
    entity_id:
      - binary_sensor.predbat_discharging
    to: "off"
    id: predbat_discharge_off
condition: []
action:
  - choose:
      - conditions:
          - condition: trigger
            id:
              - predbat_charge_on
        sequence:
          - service: switch.turn_on
            metadata: {}
            data: {}
            target:
              entity_id: switch.sunsynk_grid_charge_timezone1
      - conditions:
          - condition: trigger
            id:
              - predbat_charge_off
        sequence:
          - service: switch.turn_off
            target:
              entity_id:
                - switch.sunsynk_grid_charge_timezone1
            data: {}
      - conditions:
          - condition: trigger
            id:
              - predbat_discharge_on
        sequence:
          - service: switch.turn_on
            metadata: {}
            data: {}
            target:
              entity_id: switch.sunsynk_solar_sell
      - conditions:
          - condition: trigger
            id:
              - predbat_discharge_off
        sequence:
          - service: switch.turn_off
            target:
              entity_id:
                - switch.sunsynk_solar_sell
            data: {}
mode: single

PredBat - Copy Charge Limit

PredBat - Copy Charge Limit
description: Copy Battery SOC to all time slots
trigger:
  - platform: state
    entity_id:
      - number.sunsynk_set_soc_timezone1
    to: null
condition: []
action:
  - service: number.set_value
    data_template:
      entity_id:
        - number.sunsynk_set_soc_timezone2
        - number.sunsynk_set_soc_timezone3
        - number.sunsynk_set_soc_timezone4
        - number.sunsynk_set_soc_timezone5
        - number.sunsynk_set_soc_timezone6
      value: "{{ states('number.sunsynk_set_soc_timezone1')|int(20) }}"
mode: single

Value Templates for charge/discharge calculations

Change the 8000 to your inverter size in W

Sunsynk Battery Max Charge Rate

{{ [8000,[states('input_number.sunsynk_battery_max_charge_current_limit')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

Sunsynk Battery Max Discharge Rate

{{ [8000,[states('input_number.sunsynk_battery_max_discharge_current_limit')|int, states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

Sunsynk Charge Rate Calc

{{ [8000,[states('input_number.test_sunsynk_battery_max_charge_current')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

Sunsynk Discharge Rate Calc

{{ [8000,[states('input_number.test_sunsynk_battery_max_discharge_current')|int,states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}
@Meatballs1
Copy link
Contributor

What are the test values e.g. input_number.test_sunsynk_battery_max_charge_current ?

I currently have the following templates (slightly different naming for the BMS reported limitation):

Max Charge Rate: {{ [5000,[states('number.sunsynk_battery_max_charge_current')|int,states('sensor.sunsynk_battery_charge_bms_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}
Max Discharge Rate: {{ [5000,[states('number.sunsynk_battery_max_discharge_current')|int, states('sensor.sunsynk_battery_discharge_bms_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

But not sure what the Sunsynk Charge Rate Calc refers to - are the input numbers just helpers to manually restrict it?

@Meatballs1
Copy link
Contributor

Ah I think I see, the charge_rate/discharge_rate should be the actual power the inverter can handle, the inverter_limit_charge could just be an input number to apply a limit.

@tmh88
Copy link
Author

tmh88 commented Aug 20, 2024

Ah I think I see, the charge_rate/discharge_rate should be the actual power the inverter can handle, the inverter_limit_charge could just be an input number to apply a limit.

I think you are correct, I’ve made an error in my config. I was testing before allowing it to adjust the inverter.

@tmh88
Copy link
Author

tmh88 commented Aug 20, 2024

Below is the code for the my app.yaml and automations used to integrate my Sunsynk 8.8Kw ECCO inverter, hopefully it helps others. Thanks to @springfall2008 for the code modifications along the way.

apps.yaml

---
pred_bat:
  module: predbat
  class: PredBat

  # Sets the prefix for all created entities in HA - only change if you want to run more than once instance
  prefix: predbat

  # Timezone to work in
  timezone: Europe/London

  # If you are using Predbat outside of HA then set the HA URL and Key (long lived access token here)
  #ha_url: 'http://homeassistant.local:8123'
  #ha_key: 'xxx'

  # Currency, symbol for main currency second symbol for 1/100s e.g. $ c or £ p or e c
  currency_symbols:
    - '£'
    - 'p'

  # Number of threads to use in plan calculation
  # Can be auto for automatic, 0 for off or values 1-N for a fixed number
  threads: auto

  # Sets the maximum period of zero load before the gap is filled, default 30 minutes
  # To disable set it to 1440
  load_filter_threshold: 30

  #
  # Sensors, more than one can be specified and they will be summed up automatically
  #
  # For two inverters the load today would normally be the master load sensor only (to cover the entire house)
  # If you have three phase and one inverter per phase then you would need three load sensors
  #
  # For pv_today if you have multiple solar inverter inputs then you should include one entry for each inverter
  #
  load_today:
    - sensor.sunsynk_load_power_daily_2 # load_power_daily_kWh
  import_today:
    - sensor.smart_meter_electricity_import_today # electric_import_daily_kWh
  export_today:
    - sensor.smart_meter_electricity_total_export_daily # electric_export_daily_kWh
  pv_today:
    - sensor.sunsynk_total_pv_power_daily

  # Load forecast can be used to add to the historical load data (heat-pump)
  # To link to Predheat
  # Data must be in the format of 'last_updated' timestamp and 'energy' for incrementing kWh
  #load_forecast:
  #  - predheat.heat_energy$external
  #
  # Controls/status - must by 1 per inverter
  #
  num_inverters: 1
  inverter_type: SK


  # **** Start of Outputs to Sunsynk Inverter ****

  charge_start_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode" # Inverter work mode
    option: "Limited to Home"

  charge_stop_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode" # Inverter work mode
    option: "Limited to Home"

  discharge_start_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode"  # Inverter work mode
    option: "Selling First"   

  discharge_stop_service:
    service: select.select_option
    entity_id: "select.sunsynk_work_mode" # Inverter work mode
    option: "Limited to Home"
  timed_charge_current:
    - number.sunsynk_battery_max_charge_current # Inverter battery max charge setting in A

  timed_discharge_current:
    - number.sunsynk_battery_max_discharge_current # Inverter battery max discharge setting in A

  charge_limit:
    - number.sunsynk_set_soc_timezone1 # Inverter SOC time slot1
  # added to test need to add atuomation to copy to sunsynk timeslots

  # **** End of Outputs to Sunsynk Inverter **** 


  # Run balance inverters every N seconds (0=disabled) - only for multi-inverter
  balance_inverters_seconds: 0
  #

  # Custom sensors to get the BMS charge/discharge limit, based on inverter size (8000kW, BMS reported limit, and inverter set limit)
  inverter_limit_charge:
    - sensor.sunsynk_battery_max_charge_rate # {{ [8000,[states('input_number.sunsynk_battery_max_charge_current_limit')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  inverter_limit_discharge:
    - sensor.sunsynk_battery_max_discharge_rate # {{ [8000,[states('input_number.sunsynk_battery_max_discharge_current_limit')|int, states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  # calculations to tell predbat the actual charge/discharge power of the inverter
  charge_rate:
    - sensor.sunsynk_charge_rate_calc # {{ [8000,[states('number.sunsynk_battery_max_charge_current')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  discharge_rate:
    - sensor.sunsynk_discharge_rate_calc # {{ [8000,[states('number.sunsynk_battery_max_discharge_current')|int,states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

  battery_rate_max:
    - 8000  # The maximum rate of the battery charge/discharge in watts **required to lift the 2600w default limit**

  battery_voltage:
    - sensor.sunsynk_battery_voltage

  battery_power:
    - sensor.sunsynk_battery_output_power #in watts

  pv_power:
    - sensor.sunsynk_total_solar #in watts

  load_power:
    - sensor.sunsynk_load_power #in watts

  soc_kw:
    - sensor.bcc_battery_soc_kwh #in kWh

  soc_max:
    - input_number.battery_cappacity #in kWh

  battery_min_soc:
    - sensor.sunsynk_battery_capacity_shutdown #in %

#  reserve:
#    - sensor.sunsynk_battery_capacity_shutdown #in % (belive this is disabled for Sunsynk)

#  inverter_mode:
#    - select.givtcp_{geserial}_mode
#  inverter_time:
#    - sensor.givtcp_{geserial}_invertor_time
#  charge_start_time:
#    - select.givtcp_{geserial}_charge_start_time_slot_1
#  charge_end_time:
#    - select.givtcp_{geserial}_charge_end_time_slot_1

#  scheduled_charge_enable:
#    - switch.givtcp_{geserial}_enable_charge_schedule
#  scheduled_discharge_enable:
#    - switch.givtcp_{geserial}_enable_discharge_schedule
#  discharge_start_time:
#    - select.givtcp_{geserial}_discharge_start_time_slot_1
#  discharge_end_time:
#    - select.givtcp_{geserial}_discharge_end_time_slot_1

  # Pause mode is not supported by all firmware's and will be ignored if not present
#  pause_mode:
#   - select.givtcp_{geserial}_battery_pause_mode

  # Not all firmwares support pause start/end time, delete these if not supported
  # to avoid spurious writes/warnings
#  pause_start_time:
#   - select.givtcp_{geserial}_battery_pause_start_time_slot
#  pause_end_time:
#   - select.givtcp_{geserial}_battery_pause_end_time_slot

  # Inverter max AC limit (one per inverter). E.g for a 3.6kw inverter set to 3600
  # If you have a second inverter for PV only please add the two values together
  inverter_limit:
    - 8000 # change to inveter size in W

  # Export limit is a software limit set on your inverter that prevents exporting above a given level
  # When enabled Predbat will model this limit
  #export_limit:
  # - 3600
  # - 3600

  # Some inverters don't turn off when the rate is set to 0, still charge or discharge at around 200w
  # The value can be set here in watts to model this (doesn't change operation)
  #inverter_battery_rate_min:
  #  - 200

  # Workaround to limit the maximum reserve setting, some inverters won't allow 100% to be set
  # Comment out if your inverter allows 100%
#  inverter_reserve_max : 98

  # Some batteries tail off their charge rate at high soc%
  # enter the charging curve here as a % of the max charge rate for each soc percentage.
  # the default is 1.0 (full power)
  # The example below is from GE 9.5kwh battery with latest firmware and gen1 inverter
  #
  # Predbat can compute this curve automatically if you have enough data, restart the add-on and look in the logfile for the data
  # once set here Predbat will no longer re-compute the curve.
  # Can also be set to 'auto' to just use the calculation curve, not recommended if you are using low power charging mode.
  #battery_charge_power_curve:
  #  91 : 0.91
  #  92 : 0.81
  #  93 : 0.71
  #  94 : 0.62
  #  95 : 0.52
  #  96 : 0.43
  #  97 : 0.33
  #  98 : 0.24
  #  99 : 0.24
  #  100 : 0.24
  #battery_discharge_power_curve:
  #  4 : 1.0

  # Inverter clock skew in minutes, e.g. 1 means it's 1 minute fast and -1 is 1 minute slow
  # Separate start and end options are applied to the start and end time windows, mostly as you want to start late (not early) and finish early (not late)
  # Separate discharge skew for discharge windows only
  inverter_clock_skew_start: 0
  inverter_clock_skew_end: 0
  inverter_clock_skew_discharge_start: 0
  inverter_clock_skew_discharge_end: 0

  # Clock skew adjusts the Appdaemon time
  # This is the time that Predbat takes actions like starting discharge/charging
  # Only use this for workarounds if your inverter time is correct but Predbat is somehow wrong (AppDaemon issue)
  # 1 means add 1 minute to AppDaemon time, -1 takes it away
  clock_skew: 0

  # Solcast cloud interface, set this or the local interface below
  #solcast_host: 'https://api.solcast.com.au/'
  #solcast_api_key: 'xxxx'
  #solcast_poll_hours: 8

  # Set these to match solcast sensor names if not using the cloud interface
  # The regular expression (re:) makes the solcast bit optional
  # If these don't match find your own names in Home Assistant
  pv_forecast_today: re:(sensor.(solcast_|)(pv_forecast_|)forecast_today)
  pv_forecast_tomorrow: re:(sensor.(solcast_|)(pv_forecast_|)forecast_tomorrow)
  pv_forecast_d3: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_3|d3))
  pv_forecast_d4: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_4|d4))

  # car_charging_energy defines an incrementing sensor which measures the charge added to your car
  # is used for car_charging_hold feature to filter out car charging from the previous load data
  # Automatically set to detect Wallbox and Zappi, if it doesn't match manually enter your sensor name
  # Also adjust car_charging_energy_scale if it's not in kwH to fix the units
#  car_charging_energy: 're:(sensor.myenergi_zappi_[0-9a-z]+_charge_added_session|sensor.wallbox_portal_added_energy)'

  # Defines the number of cars modelled by the system, set to 0 for no car
  num_cars: 0

  # car_charging_planned is set to a sensor which when positive indicates the car will charged in the upcoming low rate slots
  # This should not be needed if you use Intelligent Octopus slots which will take priority if enabled
  # The list of possible values is in car_charging_planned_response
  # Auto matches Zappi and Wallbox, or change it for your own
  # One entry per car
#  car_charging_planned:
#    - 're:(sensor.wallbox_portal_status_description|sensor.myenergi_zappi_[0-9a-z]+_plug_status)'

#  car_charging_planned_response:
#    - 'yes'
#    - 'on'
#    - 'true'
#    - 'connected'
#    - 'ev connected'
#    - 'charging'
#    - 'paused'
#    - 'waiting for car demand'
#    - 'waiting for ev'
#    - 'scheduled'
#    - 'enabled'
#    - 'latched'
#    - 'locked'
#    - 'plugged in'

  # In some cases car planning is difficult (e.g. Ohme with Intelligent doesn't report slots)
  # The car charging now can be set to a sensor to indicate the car is charging and to plan
  # for it to charge during this 30 minute slot
  #car_charging_now:
  #  - off

  # Positive responses for car_charging_now
#  car_charging_now_response:
#    - 'yes'
#    - 'on'
#    - 'true'

  # To make planned car charging more accurate, either using car_charging_planned or the Octopus Energy plugin,
  # specify your battery size in kwh, charge limit % and current car battery soc % sensors/values.
  # If you have Intelligent Octopus the battery size and limit will be extracted from the Octopus Energy plugin directly.
  # Set the car SOC% if you have it to give an accurate forecast of the cars battery levels.
  # One entry per car if you have multiple cars.
  #car_charging_battery_size:
  #  - 75
  #car_charging_limit:
  #  - 're:number.tsunami_charge_limit'
  #car_charging_soc:
  #  - 're:sensor.tsunami_battery'

  # One per car, when true only one car can charge at once, when False multiple cars can charge at once
  #car_charging_exclusive:
  #  - True

  # If you have Octopus intelligent, enable the intelligent slot information to add to pricing
  # Will automatically disable if not found, or comment out to disable fully
  # When enabled it overrides the 'car_charging_planned' feature and predict the car charging based on the intelligent plan (unless octopus intelligent charging is False)
  # This matches either the intelligent slot from the Octopus Plugin or from the Intelligent plugin
  #octopus_intelligent_slot: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_intelligent_dispatching)'
  #octopus_ready_time: 're:(time.octopus_energy([0-9a-z_]+|)_intelligent_ready_time)'
  #octopus_charge_limit: 're:(number.octopus_energy([0-9a-z_]+|)_intelligent_charge_limit)'
  # Example alternative configuration for Ohme integration release >=v0.6.1
  #octopus_intelligent_slot: 'binary_sensor.ohme_slot_active'
  #octopus_ready_time: 'time.ohme_target_time'
  #octopus_charge_limit: 'number.ohme_target_percent'

  # Carbon Intensity data from National grid
  carbon_intensity: 're:(sensor.carbon_intensity_uk)'

  # Octopus saving session points to the saving session Sensor in the Octopus plugin, when enabled saving sessions will be at the assumed
  # Rate is read automatically from the add-in and converted to pence using the conversion rate below (default is 8)
  octopus_saving_session: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_saving_session(s|))'
  octopus_saving_session_octopoints_per_penny: 8

  # Energy rates
  # Please set one of these three, if multiple are set then Octopus is used first, second rates_import/rates_export and latest basic metric

  # Set import and export entity to point to the Octopus Energy plugin import and export sensors
  # automatically matches your meter number assuming you have only one (no need to edit the below)
  # Will be ignored if you don't have the sensor but will error if you do have one and it's incorrect
  # NOTE: To get detailed energy rates you need to go in and manually enable the following events in HA
  #       event.octopus_energy_electricity_xxxxxxxx_previous_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_current_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_next_day_rates
  # and if you have export enable:
  #       event.octopus_energy_electricity_xxxxxxxx_export_previous_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_export_current_day_rates
  #       event.octopus_energy_electricity_xxxxxxxx_export_next_day_rates
  # Predbat will automatically find the event. entities from the link below to the sensors
  metric_octopus_import: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_rate)'
  metric_octopus_export: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_export_current_rate)'

  # Standing charge in pounds, can be set to a sensor or manually entered (e.g. 0.50 is 50p)
  # The default below will pick up the standing charge from the Octopus Plugin
  # The standing charge only impacts the cost graphs and doesn't change the way Predbat plans
  # If you don't want to show the standing charge then just delete this line or set to zero
  metric_standing_charge: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_standing_charge)'

  # Or set your actual rates across time for import and export
  # If start/end is missing it's assumed to be a fixed rate
  # Gaps are filled with zero rate
  #rates_import:
  #  -  start: "00:30:00"
  #     end: "04:30:00"
  #     rate: 7.5
  #  -  start: "04:30:00"
  #     end: "00:30:00"
  #     rate: 40.0
  #
  #rates_export:
  #  -  rate: 4.2

  # Can be used instead of the plugin to get import rates directly online
  # Overrides metric_octopus_import and rates_import
  # rates_import_octopus_url : "https://api.octopus.energy/v1/products/FLUX-IMPORT-23-02-14/electricity-tariffs/E-1R-FLUX-IMPORT-23-02-14-A/standard-unit-rates"
  # rates_import_octopus_url : "https://api.octopus.energy/v1/products/AGILE-FLEX-BB-23-02-08/electricity-tariffs/E-1R-AGILE-FLEX-BB-23-02-08-A/standard-unit-rates"

  # Overrides metric_octopus_export and rates_export
  # rates_export_octopus_url: "https://api.octopus.energy/v1/products/FLUX-EXPORT-BB-23-02-14/electricity-tariffs/E-1R-FLUX-EXPORT-BB-23-02-14-A/standard-unit-rates"
  # rates_export_octopus_url: "https://api.octopus.energy/v1/products/AGILE-OUTGOING-BB-23-02-28/electricity-tariffs/E-1R-AGILE-OUTGOING-BB-23-02-28-A/standard-unit-rates/"
  # rates_export_octopus_url: "https://api.octopus.energy/v1/products/OUTGOING-FIX-12M-BB-23-02-09/electricity-tariffs/E-1R-OUTGOING-FIX-12M-BB-23-02-09-A/standard-unit-rates/"

  # Import rates can be overridden with rate_import_override
  # Export rates can be overridden with rate_export_override
  # Use the same format as above, but a date can be included if it just applies for a set day (e.g. Octopus power ups)
  # This will override even the Octopus plugin rates if enabled
  #
  #rates_import_override:
  # -  date: '2023-09-10'
  #    start: '14:00:00'
  #    end: '14:30:00'
  #    rate: 112
  #    load_scaling: 0.8

  # For pv estimate, leave blank for central estimate, or add 10 for 10% curve (worst case) or 90 or 90% curve (best case)
  # If you use 10 then disable pv_metric10_weight below
  # pv_estimate: 10

  # Days previous is the number of days back to find historical load data
  # Recommended is 7 to capture day of the week but 1 can also be used
  # if you have more history you could use 7 and 14 (in a list) but the standard data in HA only lasts 10 days
  days_previous:
    - 7
    - 14

  # Days previous weight can be used to control the weighting of the previous load points, the values are multiplied by their
  # weights and then divided through by the total weight. E.g. if you used 1 and 0.5 then the first value would have 2/3rd of the weight and the second 1/3rd
  # Include one value for each days_previous value, each weighting on a separate line.
  # If any days_previous's that are not given a weighting they will assume a default weighting of 1.
  days_previous_weight:
    - 1

  # Number of hours forward to forecast, best left as-is unless you have specific reason
  forecast_hours: 48

  # Specify the devices that notifies are sent to, the default is 'notify' which goes to all
  #notify_devices:
  #  - mobile_app_treforsiphone12_2

  # Battery scaling makes the battery smaller (e.g. 0.9) or bigger than its reported
  # If you have an 80% DoD battery that falsely reports it's kwh then set it to 0.8 to report the real figures
  # One per inverter
  battery_scaling:
    - 1.0

  # Can be used to scale import and export data, used for workarounds
  import_export_scaling: 1.0

  # Export triggers:
  # For each trigger give a name, the minutes of export needed and the energy required in that time
  # Multiple triggers can be set at once so in total you could use too much energy if all run
  # Creates an entity called 'binary_sensor.predbat_export_trigger_<name>' which will be turned On when the condition is valid
  # connect this to your automation to start whatever you want to trigger
  export_triggers:
    - name: 'large'
      minutes: 60
      energy: 1.0
    - name: 'small'
      minutes: 15
      energy: 0.25

  # If you have a sensor that gives the energy consumed by your solar diverter then add it here
  # this will make the predictions more accurate. It should be an incrementing sensor, it can reset at midnight or not
  # It's assumed to be in Kwh but scaling can be applied if need be
  #iboost_energy_today: 'sensor.xxxxx'
  #iboost_energy_scaling: 1.0
  # Gas rates for comparison
  #metric_octopus_gas: 're:(sensor.(octopus_energy_|)gas_[0-9a-z]+_[0-9a-z]+_current_rate)'

  # Nordpool market energy rates
  #futurerate_url: 'https://www.nordpoolgroup.com/api/marketdata/page/325?currency=GBP'
  #futurerate_adjust_import: True
  #futurerate_adjust_export: False
  #futurerate_peak_start: "16:00:00"
  #futurerate_peak_end: "19:00:00"
  #futurerate_peak_premium_import: 14
  #futurerate_peak_premium_export: 6.5

  # Watch list, a list of sensors to watch for changes and then update the plan if they change
  # This is useful for things like the Octopus Intelligent Slot sensor so that the plan update as soon as you plugin in
  # Only uncomment the items you actually have set up above in apps.yaml, of course you can add your own as well
  # Note those using +[] are lists that are appended to this list, whereas {} items are single items only
  #watch_list:
  #  - '{octopus_intelligent_slot}'
  #  - '{octopus_ready_time}'
  #  - '{octopus_charge_limit}'
  #  - '{octopus_saving_session}'
  #  - '+[car_charging_planned]'
  #  - '+[car_charging_soc]'
  #  - '{car_charging_now}'

Automations

Predbat Charge / Discharge Control

alias: Predbat Charge / Discharge Control
description: ""
trigger:
  - platform: state
    entity_id:
      - binary_sensor.predbat_charging
    to: "on"
    id: predbat_charge_on
  - platform: state
    entity_id:
      - binary_sensor.predbat_charging
    to: "off"
    id: predbat_charge_off
  - platform: state
    entity_id:
      - binary_sensor.predbat_discharging
    to: "on"
    id: predbat_discharge_on
  - platform: state
    entity_id:
      - binary_sensor.predbat_discharging
    to: "off"
    id: predbat_discharge_off
condition: []
action:
  - choose:
      - conditions:
          - condition: trigger
            id:
              - predbat_charge_on
        sequence:
          - service: switch.turn_on
            metadata: {}
            data: {}
            target:
              entity_id: switch.sunsynk_grid_charge_timezone1
      - conditions:
          - condition: trigger
            id:
              - predbat_charge_off
        sequence:
          - service: switch.turn_off
            target:
              entity_id:
                - switch.sunsynk_grid_charge_timezone1
            data: {}
      - conditions:
          - condition: trigger
            id:
              - predbat_discharge_on
        sequence:
          - service: switch.turn_on
            metadata: {}
            data: {}
            target:
              entity_id: switch.sunsynk_solar_sell
      - conditions:
          - condition: trigger
            id:
              - predbat_discharge_off
        sequence:
          - service: switch.turn_off
            target:
              entity_id:
                - switch.sunsynk_solar_sell
            data: {}
mode: single

PredBat - Copy Charge Limit

PredBat - Copy Charge Limit
description: Copy Battery SOC to all time slots
trigger:
  - platform: state
    entity_id:
      - number.sunsynk_set_soc_timezone1
    to: null
condition: []
action:
  - service: number.set_value
    data_template:
      entity_id:
        - number.sunsynk_set_soc_timezone2
        - number.sunsynk_set_soc_timezone3
        - number.sunsynk_set_soc_timezone4
        - number.sunsynk_set_soc_timezone5
        - number.sunsynk_set_soc_timezone6
      value: "{{ states('number.sunsynk_set_soc_timezone1')|int(20) }}"
mode: single

Value Templates for charge/discharge calculations

Change the 8000 to your inverter size in W

Sunsynk Battery Max Charge Rate (Sets Charge Limit)

input_number.sunsynk_battery_max_charge_current_limit = Setpoint in HA to set the charge limit in A

{{ [8000,[states('input_number.sunsynk_battery_max_charge_current_limit')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

Sunsynk Battery Max Discharge Rate (Sets Discharge Limit)

input_number.sunsynk_battery_max_discharge_current_limit = Setpoint in HA to set the discharge limit in A

{{ [8000,[states('input_number.sunsynk_battery_max_discharge_current_limit')|int, states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

Sunsynk Charge Rate Calc (Feedback to Pedbat of actual Charge Limit)

{{ [8000,[states('number.sunsynk_battery_max_charge_current')|int,states('sensor.sunsynk_battery_charge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

Sunsynk Discharge Rate Calc (Feedback to Pedbat of actual Discharge Limit)

{{ [8000,[states('number.sunsynk_battery_max_discharge_current')|int,states('sensor.sunsynk_battery_discharge_limit_current')|int]|min * states('sensor.sunsynk_battery_voltage')|float]|min }}

@tmh88
Copy link
Author

tmh88 commented Aug 20, 2024

@springfall2008 have I interpreted this correctly?
in the apps.yaml
inverter_limit_charge: & inverter_limit_discharge: are inputs to predbat to limit the charge and discharge power to the batteries

charge_rate: & discharge_rate: are inputs to predbat to tell predbat the actual charge/discharge power of the inverter

@springfall2008
Copy link
Owner

Inverter limit charge/discharge are inputs that defined the maximum rate to set

charge_rate/discharge_rate are controls, Predbat can read them to find the current rate and write them to change the rate