Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Distinguish internally between min pressure and end pressure #46

Merged
merged 1 commit into from
Oct 1, 2011
Merged

Distinguish internally between min pressure and end pressure #46

merged 1 commit into from
Oct 1, 2011

Conversation

dirkhh
Copy link
Collaborator

@dirkhh dirkhh commented Sep 30, 2011

cbcfcdd fixes only part of the problem - the program logic uses minpressure at a couple of spots where it really needs to use an endpressure

Don't artificially end dives on min pressure

This may be a problem for dive computers like Linus' Suunto Vyper Air
where the failure mode seems to be high pressure readings (that's scary,
btw). If the transmitter fails at the end of the dive the pressure plot
ends with incorrect high pressure. But that's simply a bug with the dive
computer and not something that subsurface should hack around. Maybe we
should offer a way to edit the incorrect data points instead.

Always ending on the minimum pressure is definitely wrong as it causes
bogus plots when you do a valve shutdown during the dive (which means that
valid data gets plotted incorrectly).

Signed-off-by: Dirk Hohndel dirk@hohndel.org

And don't artificially end dives on min pressure

This may be a problem for dive computers like Linus' Suunto Vyper Air
where the failure mode seems to be _high_ pressure readings (that's scary,
btw). If the transmitter fails at the end of the dive the pressure plot
ends with incorrect high pressure. But that's simply a bug with the dive
computer and not something that subsurface should hack around. Maybe we
should offer a way to edit the incorrect data points instead.

Always ending on the minimum pressure is definitely wrong as it causes
bogus plots when you do a valve shutdown during the dive (which means that
valid data gets plotted incorrectly).

Signed-off-by: Dirk Hohndel <dirk@hohndel.org>