@bruxisma bruxisma commented Sep 16, 2023

This PR will add the ability for users to set the mode, sampling average, temperature conversion time, shunt voltage conversion time, and bus voltage conversion time.

bruxisma and others added 4 commits September 16, 2023 16:23
This PR will add the ability for users to set the mode, sampling average,
temperature conversion time, shunt voltage conversion time, and bus
voltage conversion time.

Signed-off-by: Izzy Muerte <63051+bruxisma@users.noreply.github.com>
…e trusted apparently

Signed-off-by: Izzy Muerte <63051+bruxisma@users.noreply.github.com>
@clomads
Copy link
Member

clomads commented Sep 20, 2023

Very odd behavior for the ADC config with different values - not all combos tested https://wiki.vdbx.io/products/pwrtool500/ina237

@clomads
Copy link
Member

clomads commented Dec 23, 2023

QC testing notes that values do not go negative - sensor is bidirectional