DVCC: switch off inverters when DCL=0
When you receive DCL=0, switch off inverters by setting /Mode=4. When manual switch is used, the inverter disappears from dbus. Hence we cannot accidentally turn an inverter on that was manually off. For Inverter-RS, simply copy DischargeCurrent across. Firmware already switches off. victronenergy/venus#736