Notifications
You must be signed in to change notification settings - Fork 0
/
33220.cs
124 lines (118 loc) · 6.36 KB
/
33220.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
using System;
using System.Collections.Generic;
using System.Text;
using Ivi.Visa.Interop;
//'' """""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
//'' © Agilent Technologies, Inc. 2013
//''
//'' You have a royalty-free right to use, modify, reproduce and distribute
//'' the Sample Application Files (and/or any modified version) in any way
//'' you find useful, provided that you agree that Agilent Technologies has no
//'' warranty, obligations or liability for any Sample Application Files.
//''
//'' Agilent Technologies provides programming examples for illustration only,
//'' This sample program assumes that you are familiar with the programming
//'' language being demonstrated and the tools used to create and debug
//'' procedures. Agilent Technologies support engineers can help explain the
//'' functionality of Agilent Technologies software components and associated
//'' commands, but they will not modify these samples to provide added
//'' functionality or construct procedures to meet your specific needs.
//'' """""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""""
namespace CsharpExample
{
class FunctionsExample
{
static void Main(string[] args)
{
FunctionsExample DmmClass = new FunctionsExample(); //Create an instance of this class so we can call functions from Main
//For more information on getting started using VISA COM I/O operations see the app note located at:
//http://cp.literature.agilent.com/litweb/pdf/5989-6338EN.pdf
Ivi.Visa.Interop.ResourceManager rm = new Ivi.Visa.Interop.ResourceManager(); //Open up a new resource manager
Ivi.Visa.Interop.FormattedIO488 myDmm = new Ivi.Visa.Interop.FormattedIO488(); //Open a new Formatted IO 488 session
/*
AGILENT_33220A = "USB0::0x0957::0x0407::MY44021621::0::INSTR"
AGILENT_33522A = "USB0::0x0957::0x2307::MY50003961::0::INSTR"
*/
try
{
string AGILENT_33220A = "USB0::0x0957::0x0407::MY44021621::0::INSTR";
string AGILENT_33522A = "USB0::0x0957::0x2307::MY50003961::0::INSTR";
myDmm.IO = (IMessage)rm.Open(AGILENT_33220A, AccessMode.NO_LOCK, 2000, ""); //Open up a handle to the DMM with a 2 second timeout
myDmm.IO.Timeout = 3000; //You can also set your timeout by doing this command, sets to 3 seconds
//First start off with a reset state
myDmm.IO.Clear(); //Send a device clear first to stop any measurements in process
myDmm.WriteString("*RST", true); //Reset the device
myDmm.WriteString("*IDN?", true); //Get the IDN string
string IDN = myDmm.ReadString();
Console.WriteLine(IDN); //report the DMM's identity
myDmm.WriteString(":OUTP:STAT 0", true); // Disable Output
myDmm.WriteString(":SOUR:FREQ:CW 1.1512 MHZ", true);
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
myDmm.WriteString(":SOUR:VOLT:LEV:IMM:AMPL 0.1 VPP", true);
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
myDmm.WriteString(":SOUR:BURS:PHAS 0", true);
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
System.Threading.Thread.Sleep(5000);
myDmm.WriteString(":SOUR:BURS:NCYC 50000", true);
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
myDmm.WriteString(":SOUR:BURS:INT:PER 0.1 S", true);
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
myDmm.WriteString(":SOUR:FREQ?", true);
string FreqRes = myDmm.ReadString();
myDmm.WriteString(":SOUR:BURS:INT:PER?", true);
string PeriodRes = myDmm.ReadString();
myDmm.WriteString(":SOUR:VOLT:LEV:IMM:AMPL?", true);
string AmplitudeRes = myDmm.ReadString();
myDmm.WriteString(":SOUR:BURS:PHAS?", true);
string PhasResult = myDmm.ReadString();
myDmm.WriteString(":SOUR:BURS:NCYC?", true);
string NumCycRes = myDmm.ReadString();
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
Console.WriteLine("Current Values are:" + "Period:" + PeriodRes + "Frequency:" + FreqRes + "Amplitude" + AmplitudeRes + "Phase" + PhasResult + "Cycles" + NumCycRes);
myDmm.WriteString(":SOUR:BURS:STAT 1", true);
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
myDmm.WriteString(":OUTP:STAT 1", true); // Enable Output
DmmClass.CheckDMMError(myDmm); //Check if the DMM has any errors
}
catch (Exception e)
{
Console.WriteLine("Error occured: " + e.Message);
}
finally
{
//Close out your resources
try { myDmm.IO.Close(); }
catch{}
try{ System.Runtime.InteropServices.Marshal.ReleaseComObject(myDmm);}
catch {}
try{
System.Runtime.InteropServices.Marshal.ReleaseComObject(rm);
}
catch {}
/*
Console.WriteLine("Press any key to continue...");
Console.ReadKey();
*/
}
}
public void CheckDMMError(FormattedIO488 myDmm)
{
myDmm.WriteString("SYST:ERR?", true);
string errStr = myDmm.ReadString();
if (errStr.Contains("No error")) //If no error, then return
return;
//If there is an error, read out all of the errors and return them in an exception
else
{
string errStr2 = "";
do
{
myDmm.WriteString("SYST:ERR?", true);
errStr2 = myDmm.ReadString();
if (!errStr2.Contains("No error")) errStr = errStr + "\n" + errStr2;
} while (!errStr2.Contains("No error"));
throw new Exception("Exception: Encountered system error(s)\n" + errStr);
}
}
}
}