forked from openhab/openhab-addons
-
Notifications
You must be signed in to change notification settings - Fork 0
/
configuration_parameters.xml
101 lines (98 loc) · 4.03 KB
/
configuration_parameters.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
<?xml version="1.0" encoding="UTF-8"?>
<config-description:config-descriptions
xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:config-description="https://openhab.org/schemas/config-description/v1.0.0"
xsi:schemaLocation="https://openhab.org/schemas/config-description/v1.0.0 https://openhab.org/schemas/config-description-1.0.0.xsd">
<config-description uri="thing-type:dsmr:bridgesettings">
<parameter name="serialPort" type="text" required="true">
<context>serial-port</context>
<limitToOptions>false</limitToOptions>
<label>Serial Port</label>
<description>The serial port where the P1 port of the Smart Meter is connected (e.g. Linux: /dev/ttyUSB0, Windows:
COM1)</description>
</parameter>
<parameter name="receivedTimeout" type="integer" min="1">
<default>30</default>
<label>Received Timeout</label>
<description>The time period within results are expected in seconds</description>
</parameter>
<parameter name="baudrate" type="integer">
<advanced>true</advanced>
<label>Baud Rate</label>
<description>Set the baud rate in case auto detect fails.</description>
<options>
<option value="4800">4800</option>
<option value="9600">9600</option>
<option value="19200">19200</option>
<option value="38400">38400</option>
<option value="57600">57600</option>
<option value="115200">115200</option>
</options>
</parameter>
<parameter name="databits" type="integer">
<advanced>true</advanced>
<label>Data Bits</label>
<description>Set the data bits in case auto detect fails.</description>
<options>
<option value="5">5</option>
<option value="6">6</option>
<option value="7">7</option>
<option value="8">8</option>
</options>
</parameter>
<parameter name="parity" type="text">
<advanced>true</advanced>
<label>Parity</label>
<description>Set the parity in case auto detect fails.</description>
<options>
<option value="E">E(ven)</option>
<option value="O">O(dd)</option>
<option value="N">N(ormal)</option>
</options>
</parameter>
<parameter name="stopbits" type="text">
<advanced>true</advanced>
<label>Stop Bits</label>
<description>Set the stop bits in case auto detect fails.</description>
<options>
<option value="1">1</option>
<option value="1.5">1.5</option>
<option value="2">2</option>
</options>
</parameter>
</config-description>
<config-description uri="thing-type:dsmr:smartybridgesettings">
<parameter name="serialPort" type="text" required="true">
<context>serial-port</context>
<limitToOptions>false</limitToOptions>
<label>Serial Port</label>
<description>The serial port where the P1 port of the Smart Meter is connected (e.g. Linux: /dev/ttyUSB0, Windows:
COM1)</description>
</parameter>
<parameter name="decryptionKey" type="text" required="true">
<label>Decryption Key</label>
<description>The Luxembourgian Smart meter decryption key. Ask for your energy grid operator for your Smart meter P1
key.</description>
</parameter>
<parameter name="receivedTimeout" type="integer" min="1">
<default>30</default>
<label>Received Timeout</label>
<description>The time period within results are expected in seconds</description>
</parameter>
</config-description>
<config-description uri="thing-type:dsmr:meterdescriptor">
<parameter name="refresh" type="integer" min="1">
<default>60</default>
<label>Refresh</label>
<description>The time interval the data is refreshed in seconds</description>
</parameter>
<parameter name="channel" type="integer">
<advanced>true</advanced>
<label>Channel</label>
<description><![CDATA[ The DSMR-device channel for this meter (M-Bus channel).
The binding will auto detect this value. In normal situations it is not necessary to adapt this value.
If the auto detection failed or if physical changes are made to the meter setup (changed water, gas, heating) meters
it can be necessary to update the M-Bus channel.]]></description>
</parameter>
</config-description>
</config-description:config-descriptions>