JMA proposes an amendment to Common Code table C-3 to introduce new models of XCTD (eXpendable Conductivity Temperature Depth profiler) probes.
Action proposed
JMA asks the team to review the proposal and accept it for FT2020-2.
Discussions
New models of XCTD probes (XCTD-1N, XCTD-2N, XCTD-3N and XCTD-4N) will be introduced by TSK (Tsurumi-seiki Co., Ltd).
New specifications in the table are the same as the current XCTD probes (XCTD-1, XCTD-2, XCTD-3 and XCTD-4).
It would not be necessary to identify a type of new/old models.
We propose to add new models into "Instrument make and type" in "Meaning" of current numbers instead of allocation of new parameter numbers.
Detailed proposal
Amendment to Common Code table C-3 by Japan
AMEND
Add 'XCTD-1N', 'XCTD-2N', 'XCTD-3N' and 'XCTD-4N' to "Instrument make and type" respectively.
In Common Code table C-3
Code figure for IxIxIx
Code figure for BUFR (Code table 0 22 067)
Instrument make and type
Equation Coefficients (a)
Equation Coefficients (b)
741
741
TSK XCTD/XCTD-1/XCTD-1N
3.42543
-0.47
742
742
TSK XCTD-2/XCTD-2N
3.43898
-0.31
743
743
TSK XCTD-2F
3.43898
-0.31
744
744
TSK XCTD-3/XCTD-3N
5.07598
-0.72
745
745
TSK XCTD-4/XCTD-4N
3.68081
-0.47
The text was updated successfully, but these errors were encountered:
Summary and purpose
JMA proposes an amendment to Common Code table C-3 to introduce new models of XCTD (eXpendable Conductivity Temperature Depth profiler) probes.
Action proposed
JMA asks the team to review the proposal and accept it for FT2020-2.
Discussions
New models of XCTD probes (XCTD-1N, XCTD-2N, XCTD-3N and XCTD-4N) will be introduced by TSK (Tsurumi-seiki Co., Ltd).
New specifications in the table are the same as the current XCTD probes (XCTD-1, XCTD-2, XCTD-3 and XCTD-4).
It would not be necessary to identify a type of new/old models.
We propose to add new models into "Instrument make and type" in "Meaning" of current numbers instead of allocation of new parameter numbers.
Detailed proposal
Amendment to Common Code table C-3 by Japan
AMEND
Add 'XCTD-1N', 'XCTD-2N', 'XCTD-3N' and 'XCTD-4N' to "Instrument make and type" respectively.