Skip to content

Commit

Permalink
power: supply: bq24190: Call power_supply_changed() after updating in…
Browse files Browse the repository at this point in the history
…put current

commit 77c2a30 upstream.

The bq24192 model relies on external charger-type detection and once
that is done the bq24190_charger code will update the input current.

In this case, when the initial power_supply_changed() call is made
from the interrupt handler, the input settings are 5V/0.5A which
on many devices is not enough power to charge (while the device is on).

On many devices the fuel-gauge relies in its external_power_changed
callback to timely signal userspace about charging <-> discharging
status changes. Add a power_supply_changed() call after updating
the input current. This allows the fuel-gauge driver to timely recheck
if the battery is charging after the new input current has been applied
and then it can immediately notify userspace about this.

Fixes: 18f8e6f ("power: supply: bq24190_charger: Get input_current_limit from our supplier")
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
  • Loading branch information
jwrdegoede authored and gregkh committed May 30, 2023
1 parent 6676e0a commit f0df9f7
Showing 1 changed file with 1 addition and 0 deletions.
1 change: 1 addition & 0 deletions drivers/power/supply/bq24190_charger.c
Expand Up @@ -1262,6 +1262,7 @@ static void bq24190_input_current_limit_work(struct work_struct *work)
bq24190_charger_set_property(bdi->charger,
POWER_SUPPLY_PROP_INPUT_CURRENT_LIMIT,
&val);
power_supply_changed(bdi->charger);
}

/* Sync the input-current-limit with our parent supply (if we have one) */
Expand Down