12 changes: 6 additions & 6 deletions 10ma-rcbo-and-anti-external-cb-trip/README.md
Expand Up @@ -2,30 +2,30 @@

This is a combination of the [10mA RCBO](../10ma-rcbo) and the [trip-10ma-rccb-only-tool](../trip-10ma-rccb-only-tool/).

##Demo video on Youtube
## Demo video on Youtube
[![](http://img.youtube.com/vi/h-DokWP5Kic/0.jpg)](http://www.youtube.com/watch?v=h-DokWP5Kic)

##Photos
## Photos
![Screen](images/10ma-rcbo-and-anti-external-cb-trip-front-open.jpg)

![Screen](images/10ma-rcbo-and-anti-external-cb-trip-spacer.jpg)

##Usage instructions
## Usage instructions

1) Do NOT set up without prior training.
2) Always test before use.
a. Only the 10mA RCCB should trip
b. If it does not, there may be a problem with the external Earth connection or with this tool. Do not continue to use.
3) All other RK electrical connections will be connected through this.

##Design
## Design
![Screen](10ma-rcbo-and-anti-external-cb-trip.png)
Electrical schematic in Eagle format.

![Screen](images/10ma-rcbo-and-anti-external-cb-trip-internal.jpg)

##Parts
1. [ABB DS201, 10mA, 1+N, 10A, Type B RCBO](https://sg.rs-online.com/web/p/rcbos/7674049/)
## Parts
1. [ABB DS201, 10mA, 1+N, 10A, Type B RCBO](https://sg.rs-online.com/web/p/rcbos/7674049/)
2. [2x Schneider Electric 2 Pole DIN Rail Mount Non-Fused Switch Disconnector, 2NO, 20 A, IP40](https://sg.rs-online.com/web/p/non-fused-switch-disconnectors/7907434/)
3. [ABB 1 Gang Unswitched Electrical Socket, Type G - British, 13A, DIN Rail Mount, IP20, IP30](https://sg.rs-online.com/web/p/electrical-sockets/8294571/)
4. [AC Multimeter D52-2042](http://www.aliexpress.com/item/DIN-RAIL-Dual-led-display-Red-green-AC80-300V-AC0-1-99-9A-Digital-voltmeter-ammeter/32304010220.html)
Expand Down
12 changes: 6 additions & 6 deletions 10ma-rcbo-mcb-and-anti-external-cb-trip/README.md
Expand Up @@ -2,26 +2,26 @@

This is an improvement of the [10ma-rcbo-and-anti-external-cb-trip](../10ma-rcbo-and-anti-external-cb-trip/) with 2 extra MCBs. As of September 2016, I have dropped the use of the B3 MCB as it is too sensitive for typical use. It is left unconnected in the box.

##Photos
## Photos
![Screen](images/10ma-rcbo-mcb-and-anti-external-cb-trip-front-open.jpg)

##Usage instructions
## Usage instructions
1. Do NOT set up without prior training.
2. Always test RCBO before use.
2. Always test RCBO before use.
a. Only the 10mA RCCB should trip.
b. If it does not, there may be a problem with the external Earth connection or with this tool. Do not continue to use.
3. Only test MCB if you are ready for a trip of your onsite MCB.
4. All other RK electrical connections will be connected through this.
5. If the “B6 MCB” keeps tripping due to high-current appliance, you can temporarily engage the “Bypass B6 MCB” switch.

##Design
## Design
![Screen](10ma-rcbo-mcb-and-anti-external-cb-trip.png)
Electrical schematic in Eagle format.

![Screen](images/10ma-rcbo-mcb-and-anti-external-cb-trip-internal.jpg)

##Parts
1. [ABB DS201, 10mA, 1+N, 10A, Type B RCBO](https://sg.rs-online.com/web/p/rcbos/7674049/)
## Parts
1. [ABB DS201, 10mA, 1+N, 10A, Type B RCBO](https://sg.rs-online.com/web/p/rcbos/7674049/)
2. [5x Schneider Electric 2 Pole DIN Rail Mount Non-Fused Switch Disconnector, 2NO, 20 A, IP40](https://sg.rs-online.com/web/p/non-fused-switch-disconnectors/7907434/)
3. [ABB 1 Gang Unswitched Electrical Socket, Type G - British, 13A, DIN Rail Mount, IP20, IP30](https://sg.rs-online.com/web/p/electrical-sockets/8294571/)
4. [AC Multimeter D52-2042](http://www.aliexpress.com/item/DIN-RAIL-Dual-led-display-Red-green-AC80-300V-AC0-1-99-9A-Digital-voltmeter-ammeter/32304010220.html)
Expand Down
8 changes: 4 additions & 4 deletions 10ma-rcbo/README.md
Expand Up @@ -2,10 +2,10 @@

A more sensitive 10ma residual-current circuit breaker with overcurrent protection (RCBO) compared to conventional 30mA earth-leakage breakers. An AC voltmeter and ammeter (using hall-effect sensor) is also onboard.

##Demo video on Youtube
## Demo video on Youtube
[![](http://img.youtube.com/vi/OJdND4VS1W4/0.jpg)](http://www.youtube.com/watch?v=OJdND4VS1W4)

##Photos
## Photos
![Screen](10ma-rcbo-front.jpg)

One of the LCD cells is faulty..
Expand All @@ -17,8 +17,8 @@ Earth trip. Switch and blue tab is down.
Overload trip. Only the switch is down.


##Parts
1. [ABB DS201, 10mA, 1+N, 10A, Type B RCBO](https://sg.rs-online.com/web/p/rcbos/7674049/)
## Parts
1. [ABB DS201, 10mA, 1+N, 10A, Type B RCBO](https://sg.rs-online.com/web/p/rcbos/7674049/)
2. [AC voltmeter and ammeter](http://www.aliexpress.com/item/AC-Digital-Ammeter-Voltmeter-Dual-Digital-LCD-Panel-Amp-Volt-Current-Meter-100A-80-300V-w/32264125864.html)
3. DIN rail mount
4. Dual 3-pin sockets
6 changes: 3 additions & 3 deletions README.md
@@ -1,7 +1,7 @@
# repair-kopitiam-training-and-equipment
Training materials and equipment schematics for Repair Kopitiam.

##Hackware talk
## Hackware talk

I gave a talk about these equipment at [Hackware v2.0](https://www.facebook.com/events/481593632030061/) on 27 July 2016. Here are the slides.

Expand All @@ -11,7 +11,7 @@ Here is the video

[![](http://img.youtube.com/vi/OkuFtGhXB7U/0.jpg)](http://www.youtube.com/watch?v=OkuFtGhXB7U)

##Training materials
## Training materials

Files of the slides and simulation material are found in the [training directory](training). Slides can be viewed using the picture link below.

Expand All @@ -21,7 +21,7 @@ Files of the slides and simulation material are found in the [training directory



##Equipment
## Equipment

An oveview of all the specialty equipment.

Expand Down
10 changes: 5 additions & 5 deletions anti-trip-earth-leakage-detector/README.md
Expand Up @@ -2,13 +2,13 @@

Tool to prevent circuit breaker trips on both 10mA and 30mA residual current breakers when encountering appliances with earth leakage. An LED indicator will display when an earth leak is detected. This tool should be used in conjunction with the [10mA RCBO](../10ma-rcbo) connected somewhere upstream.

##Demo video on Youtube
## Demo video on Youtube
[![](http://img.youtube.com/vi/tSpie7baYFM/0.jpg)](http://www.youtube.com/watch?v=tSpie7baYFM)

##Photo
## Photo
![Screen](anti-trip-earth-leakage-detector-front.jpg)

##Usage instructions
## Usage instructions

1. Do NOT use without prior training or supervision.
2. Upstream power source must have a 10mA RCD/RCCB/RCBO. Always test before use.
Expand All @@ -18,14 +18,14 @@ Tool to prevent circuit breaker trips on both 10mA and 30mA residual current bre
6. Be ready to cut power immediately once the blue light comes on or if you notice abnormal behaviour in the appliance.
7. After repairing, plug the appliance to a conventional socket and verify that the breaker does not trip under normal circumstances.

##Design
## Design
![Screen](anti-trip-earth-leakage-detector.png)
Electrical schematic in Eagle format. I put 2 LEDS in opposite directions to ensure that the AC current can still flow throughout all phases.

![Screen](anti-trip-earth-leakage-detector-internal.jpg)
The rightmost button has been converted to a test button where the socket live is connected to the earth line by a green wire to simulate a faulty appliance. If pressed, the blue LEDS should light up with no trip on either the 10mA or 30mA RCCB/RCBO.

##Parts
## Parts
1. Any power strip with a translucent area so the LEDs are visible.
2. [62k ohm, 2W, 5% throughhole resistor](http://sg.element14.com/vishay-bc-components/pr02000206202jr500/metal-film-resistor-62-kohm-2/dp/3173483)
3. [2x blue 5mm LEDS, 20mA, 6000mcd](http://sg.element14.com/multicomp/mcl053ublc-2z-2-8/led-5mm-blue-600mcd-470nm/dp/2365811)
10 changes: 5 additions & 5 deletions trip-10ma-rccb-only-tool/README.md
Expand Up @@ -2,13 +2,13 @@

Tool to ensure earth-leakage trips only the 10mA earth leakage circuit breaker and not typical 30mA onsite breakers. This tool must be used in conjunction with the [10mA RCBO](../10ma-rcbo).

##Demo video on Youtube
## Demo video on Youtube
[![](http://img.youtube.com/vi/OAcWiW7V_oI/0.jpg)](http://www.youtube.com/watch?v=OAcWiW7V_oI)

##Photo
## Photo
![Screen](trip-10ma-rccb-only-tool-front.jpg)

##Usage instructions
## Usage instructions

1) Do NOT set up without prior training.
2) Must plug DIRECTLY to 10mA RCCB/RCBO
Expand All @@ -17,14 +17,14 @@ a. Red LED should blink for an instant
b. Only the 10mA RCCB should trip
4) All other RK electrical connections will be connected to this bar.

##Design
## Design
![Screen](trip-10ma-rccb-only-tool.png)
Electrical schematic in Eagle format. I put 2 LEDS in opposite directions to ensure that the AC current can still flow throughout all phases.

![Screen](trip-10ma-rccb-only-tool-internal.jpg)
The rightmost button has been converted to a test button where the socket live is connected to the earth line by a red wire to simulate a faulty appliance. If pressed, the red LEDs will blink for an instant and only the 10mA RCCB/RCBO will trip, not the 30mA onsite breaker.

##Parts
## Parts
1. Any power strip with a translucent area so the LEDs are visible.
2. [20k ohm, 3W, 5% throughhole resistor](http://sg.element14.com/vishay-bc-components/pr03000202002jac00/metal-film-resistor-20-kohm-3/dp/1755172)
3. [2x red 5mm LEDS, 20mA, 400mcd](http://sg.element14.com/multicomp/703-0100/led-5mm-red-400mcd-643nm/dp/2112111)