Scale down Castor photoelectron gain at digi step to avoid saturation in simulation of PbPb #2035

Commits on Jan 15, 2014

  1. pmt gain, photoelectronsToAnalog, set to 4.24 by 20 to work around sa…

    …turation in PbPb simulation; this assumes also a corresponding check of conditions
    iik1997 committed Jan 15, 2014
    Copy the full SHA
    d41d9ef View commit details
    Browse the repository at this point in the history

Commits on Feb 16, 2014

  1. -- Set back Castor photoelectron gain (photoelectronsToAnalog) to the…

    … value appropriate for pPb simulation as it initially was for 1st 53X releases.
    
    -- Added three custom fragments with the Castor photoelectron gain values appropriate for all possible cases that is for pp, pPb, PbPb simulation.
    -- Tested the fragments both at GEN-SIM (the same way as it was working for original SimWithCastor_cff) and DIGI steps (where photoelectronsToAnalog is in fact used).
    -- Each fragment requires a matching set of conditions (CastorGains).
    -- Hopefully now the solution should be universal within 53X.
    iik1997 committed Feb 16, 2014
    Copy the full SHA
    79bbb7a View commit details