Reason of confusion is the inconsistency of the RepresentationSystem.xml:
vrTillageDepthTarget has DDI 51 which is "Setpoint Tillage Depth", there is no vrTillageDepthSetPoint
vrAppHeightTarget has DDI 61 which is "Setpoint Working Height", there is no vrAppHeightSetPoint
vrTillagePressureTarget has DDI 365 which is "Setpoint downforce pressure for an operation", there is no vrTillagePressureSetPoint
vs
vrSeedRateMassTarget has DDI 8 which is" Default Application Rate specified as mass per area", there is a vrSeedRateMassSetPoint with DDI 6
vs
vrSeedDepthTarget has DDI 58 which is "Default Seeding Depth", there is no vrSeedDepthSetPoint
vs
vrSievePositionTarget and vrSievePositionSetPoint have the same DDI 242
vrFanSpeedTarget and vrFanSpeedSetPoint have the same DDi 254
vs
vrAppRateVolumeTarget has no DDI, there is a vrAppRateVolumeSetPoint with DDI 1 which is Setpoint Application Rate
What is the difference between vr[...]Setpoint, vr[...]Target? Isn't Target and SetPoint the same?
If so, then the names of each vr[...]Target should change to vr[...]Default: e.g.
Note: this means that each vr[...]Default has to have the correct Related DDI.
Jason Roesbeke, jason.roesbeke@cnhind.com
The text was updated successfully, but these errors were encountered: