I didn't look at the RX300 yet; since it's an unusual multi-cell box, it may (certainly will) take some time to adapt. |
For those of you ready to take some risks, I made an experimental RX300 version of the firmware. Since I have no RX300 by hand I cannot test by myself so I must rely on the good wills down there. |
it loads fine and works as in you can use menus but it comes up with flashing battery icon at bottom and when you hit fire button it say check battery's i changed to fully charged set dose same .menu seams to all work apart from it will not fire |
What do the battery voltages read for each of the four cells? |
Ok I found a bug in battery reading. |
Thank you for your help, BTW^^ |
that has solved battery problem now as you hit fire it says device to hot flashing up |
no problem with helping as love your firmware |
i have been though all the menus now and as far as i can tell it all works .just the device to hot when you hit fire button |
What's the board temp? |
85 c then i hit fire button to see broad temp 10 times and its now reset self to 30 c do you want me to reload firmware again see if it dose this again ? i just changed battery's over and its saying device to hot with mod temp at 85c and this time it will not work or reset if i hit fire button 10 times like be for so what i have done is reloaded firmware and hit fire button loads and its reset temp and works. hit fire button 10 times and mod temp is 36 and working fine take battery's out and its reset temp to 85 and have to do same again reinstall firmware and hit fire button loads .now i have removed battery's and done the above and it works now its saying weak battery's as it fires up it still vapes batts are at 64%. removed battery.s again did the above and it stuck with temp on 85 , so reinstalled stock firmware and works fine ,now did reinstall your firmware and stuck with device to hot at 85c now back to stock firmware |
I found a bug in temp sensing. It should work better. |
wheres bin file ? to test |
Here, that's always the same link. |
ok my bad thanks well temp problem solved now and working ok so far only thing i cant seam to get 10 clicks for temp up 20 clicks for firmware works but 10 clicks nothing happens will keep trying as its always been hit and miss with that one as far as i can tell it all works clock works and every thing else in menus works |
Fine, I released it. We can wait a bit for USB charging - not an essential feature on a 4 cells box, anyway. |
well charging it with usb is not good thing anyways best to remove and charge in proper charger , have tested with sock firmware using usb to charge and it very in balanced so would not use |
New prototype version, with supposedly functional battery charging, including balancing. Note about balancing: the box balances the load at end of charge, that is when one of the cells has been fully charged and others are still late. Half-charging will not balance. Balancing should set cells within 0.03V from each others. Testers needed. |
@docdeath Did you test this one? |
@ClockSelect AM testing at moment will let you know asap |
@ClockSelect it all seems to be working as it should not fully charged as yet but battery's are close to each other tested with dig volt meter .04 will give full charge tomm and see if any changes |
@ClockSelect fully charged 30q Samsung with all battery's with in 0.5 off each other |
I hope you meant 0.05^^ |
Does it works with RX2/3 or RX200S? |
RX2/3 and RX200S work as usual. Cell balancing is specific to the RX300. |
So RX300 has balancing IC? |
Sort of |