2.0rc4 The "little" update

27 Apr 17:35
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Updates:

  • Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
  • Added secondary CPM and count displays in measurement views.
  • Improved haptic pulse strengths.
  • Improved FNIRSI GC-01 quiet pulse clicks.
  • Improved selected menu item contrast.
  • Improved datalogging time precision.
  • Fixed History (24 h) bug.

2.0rc3 The "BIG" update

21 Apr 02:49
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Updates:

  • UI update with BIG numbers.
  • Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
  • History alert zones (1 µSv, 10 µSv).
  • Average timer expiration after reaching a configurable confidence interval.
  • Background compensation.
  • Display flashes on the FNIRSI GC-01 (after display sleep).
  • Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
  • Pulses threshold (disables pulse indication if instantaneous rate is below a certain value).
  • Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
  • Added 30 second and 10 second datalog interval options.
  • Added 10 second display sleep option.
  • Added radpro-flashtool.
  • Removed hold option.

2.0rc2

22 Mar 23:14
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Updates:

  • Changed default display theme to Dusk.
  • Fixed flash programming code.
  • Fixed FNIRSI GC-01 battery indicator.
  • Fixed conversion factor menu logic.

1.3.0

10 Jul 07:11
Compare
Choose a tag to compare

By downloading this software, you agree to the Rad Pro terms and conditions.

Note: Rad Pro 1.3.0 uses a new settings format, thus requiring an installation rather than an update.

Updates:

  • Added data logging.
  • Added custom conversion factors.
  • Added support for the J305 Geiger tube.
  • Minor bug fixes.

1.2.2

28 Jun 19:58
Compare
Choose a tag to compare
  • Added support for devices with a GD32 microcontroller.
  • Added data submission to the https://gmcmap.com/ radiation monitoring website.

1.2.1

19 Jun 17:14
Compare
Choose a tag to compare

Note: If you update from 1.1.1 or previous, use the "-install" versions, as 1.2.0 uses a new settings format.

  • Minor bugfixes.

1.2.0

18 Jun 23:42
Compare
Choose a tag to compare

Note: Rad Pro 1.2.0 uses a new settings format, thus requiring an installation rather than an update.

  • Implemented storage of radiation dose in non-volatile memory.
  • Added the capability to store device statistics every hour.
  • Added client for the https://radmon.org radiation monitoring website.
  • Improved the font_tiny5 5-pixel font.
  • Enhanced battery level calculation using battery discharge curves and HV pulse syncing for shot noise removal.
  • Improved flash settings and state storage.
  • Fixed a start-up sequence bug.
  • Fixed a backlight bug when turning off the device.
  • Corrected the SBM-20 conversion ratio.

1.1.1

15 May 21:52
Compare
Choose a tag to compare
  • Minor bug fix

1.1.0

10 May 02:01
Compare
Choose a tag to compare
  • Added Geiger-Müller tube type settings.
  • Added backlight pulse flash setting.
  • Added true random number generator.
  • Added support for the SBM-20 and SI-3BG Geiger-Müller tube.
  • Ported the project to the platform.io environment.
  • Improved battery level sampling.
  • Fixed rounding errors.
  • Improved usage instructions.

1.0.2

10 Jan 04:44
Compare
Choose a tag to compare
  • Added support for M4011 Geiger-Müller tube.
  • Fixed battery indicator.