2.0rc4 The "little" update
By downloading this software, you agree to the Rad Pro terms and conditions.
Updates:
- Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
- Added secondary CPM and count displays in measurement views.
- Improved haptic pulse strengths.
- Improved FNIRSI GC-01 quiet pulse clicks.
- Improved selected menu item contrast.
- Improved datalogging time precision.
- Fixed History (24 h) bug.
2.0rc3 The "BIG" update
By downloading this software, you agree to the Rad Pro terms and conditions.
Updates:
- UI update with BIG numbers.
- Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
- History alert zones (1 µSv, 10 µSv).
- Average timer expiration after reaching a configurable confidence interval.
- Background compensation.
- Display flashes on the FNIRSI GC-01 (after display sleep).
- Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
- Pulses threshold (disables pulse indication if instantaneous rate is below a certain value).
- Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
- Added 30 second and 10 second datalog interval options.
- Added 10 second display sleep option.
- Added
radpro-flashtool
. - Removed hold option.
2.0rc2
By downloading this software, you agree to the Rad Pro terms and conditions.
Updates:
- Changed default display theme to Dusk.
- Fixed flash programming code.
- Fixed FNIRSI GC-01 battery indicator.
- Fixed conversion factor menu logic.
1.3.0
By downloading this software, you agree to the Rad Pro terms and conditions.
Note: Rad Pro 1.3.0 uses a new settings format, thus requiring an installation rather than an update.
Updates:
- Added data logging.
- Added custom conversion factors.
- Added support for the J305 Geiger tube.
- Minor bug fixes.
1.2.2
- Added support for devices with a GD32 microcontroller.
- Added data submission to the https://gmcmap.com/ radiation monitoring website.
1.2.1
1.2.0
Note: Rad Pro 1.2.0 uses a new settings format, thus requiring an installation rather than an update.
- Implemented storage of radiation dose in non-volatile memory.
- Added the capability to store device statistics every hour.
- Added client for the https://radmon.org radiation monitoring website.
- Improved the font_tiny5 5-pixel font.
- Enhanced battery level calculation using battery discharge curves and HV pulse syncing for shot noise removal.
- Improved flash settings and state storage.
- Fixed a start-up sequence bug.
- Fixed a backlight bug when turning off the device.
- Corrected the SBM-20 conversion ratio.
1.1.1
1.1.0
- Added Geiger-Müller tube type settings.
- Added backlight pulse flash setting.
- Added true random number generator.
- Added support for the SBM-20 and SI-3BG Geiger-Müller tube.
- Ported the project to the platform.io environment.
- Improved battery level sampling.
- Fixed rounding errors.
- Improved usage instructions.