Skip to content

Commit

Permalink
Allow upwinding in 1D Heat exchanger (#1383)
Browse files Browse the repository at this point in the history
* changes

* Test config validation

* add back original countercurrent test

* Run Black

* Add back tests lost in merge

* Comment on logic of test

* somehow config.yaml returned

* actually commit comment

* caution

* divide tests

* black

* test block triangularization for collocation

* scale model

---------

Co-authored-by: Andrew Lee <andrew.lee@netl.doe.gov>
  • Loading branch information
dallan-keylogic and andrewlee94 committed May 16, 2024
1 parent 17e9e11 commit f0c60c4
Show file tree
Hide file tree
Showing 4 changed files with 945 additions and 237 deletions.
9 changes: 8 additions & 1 deletion idaes/logger.py
Original file line number Diff line number Diff line change
Expand Up @@ -26,14 +26,16 @@
CRITICAL = logging.CRITICAL # 50
ERROR = logging.ERROR # 40
WARNING = logging.WARNING # 30
CAUTION = 25
INFO_LOW = 21 # Most important info
INFO = logging.INFO # 20 #Medium info (default)
INFO_HIGH = 19 # Less important important info
DEBUG = logging.DEBUG # 10
NOTSET = logging.NOTSET # 0


levelname = { # the level name of all our extra info levels is "INFO"
levelname = {
CAUTION: "CAUTION",
INFO_HIGH: "INFO",
INFO_LOW: "INFO",
}
Expand All @@ -57,6 +59,10 @@ def filter(record):
return False


def __caution(self, *args, **kwargs):
self.log(CAUTION, *args, **kwargs)


def __info_low(self, *args, **kwargs):
self.log(INFO_LOW, *args, **kwargs)

Expand All @@ -69,6 +75,7 @@ def __add_methods(log, tag=None):
# pylint: disable=assignment-from-no-return,no-value-for-parameter
log.addFilter(_TagFilter)
log = logging.LoggerAdapter(log, {"tag": tag})
log.caution = __caution.__get__(log)
log.info_high = __info_high.__get__(log)
log.info_low = __info_low.__get__(log)
# hopefully adding this multiple times is not a problem
Expand Down
198 changes: 119 additions & 79 deletions idaes/models/unit_models/heat_exchanger_1D.py
Original file line number Diff line number Diff line change
Expand Up @@ -430,96 +430,125 @@ def build(self):

# Set flow directions for the control volume blocks and specify
# discretization if not specified.
if self.config.flow_type == HeatExchangerFlowPattern.cocurrent:
set_direction_hot = FlowDirection.forward
set_direction_cold = FlowDirection.forward
if self.config.hot_side.transformation_method is useDefault:
_log.info(
"Discretization method was "
"not specified for the hot side of the "
"heat exchanger. "
"Defaulting to finite "
"difference method on the hot side."
)
self.config.hot_side.transformation_method = "dae.finite_difference"
if self.config.cold_side.transformation_method is useDefault:
_log.info(
"Discretization method was "
"not specified for the cold side of the "
"heat exchanger. "
"Defaulting to finite "
"difference method on the cold side."
)
self.config.cold_side.transformation_method = "dae.finite_difference"

if (
self.config.hot_side.transformation_method
!= self.config.cold_side.transformation_method
):
raise ConfigurationError(
"HeatExchanger1D only supports the same transformation "
"method on the hot and cold side domains for "
"both cocurrent and countercurrent flow patterns. "
f"Found method {self.config.hot_side.transformation_method} "
f"on hot side and method {self.config.cold_side.transformation_method} "
"on cold side."
)
if self.config.hot_side.transformation_method == "dae.collocation":
if (
self.config.hot_side.transformation_scheme is useDefault
or self.config.cold_side.transformation_scheme is useDefault
):
raise ConfigurationError(
"If a collocation method is used for HeatExchanger1D, the user "
"must specify the transformation scheme they want to use."
)
if (
self.config.hot_side.transformation_method
!= self.config.cold_side.transformation_method
) or (
self.config.hot_side.transformation_scheme
!= self.config.cold_side.transformation_scheme
):
raise ConfigurationError(
"HeatExchanger1D only supports similar transformation "
"schemes on the hot and cold side domains for "
"both cocurrent and countercurrent flow patterns."
"If a collocation method is used, "
"HeatExchanger1D only supports the same transformation "
"scheme on the hot and cold side domains. Found "
f"{self.config.hot_side.transformation_scheme} scheme on "
f"hot side and {self.config.cold_side.transformation_scheme} "
"scheme on cold side."
)
if self.config.hot_side.transformation_method is useDefault:
_log.warning(
"Discretization method was "
"not specified for the hot side of the "
"co-current heat exchanger. "
"Defaulting to finite "
"difference method on the hot side."
)
self.config.hot_side.transformation_method = "dae.finite_difference"
if self.config.cold_side.transformation_method is useDefault:
_log.warning(
"Discretization method was "
"not specified for the cold side of the "
"co-current heat exchanger. "
"Defaulting to finite "
"difference method on the cold side."
else:
if (
self.config.hot_side.transformation_scheme
!= self.config.cold_side.transformation_scheme
):
_log.caution(
"The hot and cold sides are being discretized with different "
"discretization schemes. While this may result in better numerical "
"stability if an upwind scheme is used, it may also result in "
"energy conservation errors. High-order collocation methods can "
"provide both accuracy and numerical stability."
)
self.config.cold_side.transformation_method = "dae.finite_difference"
if self.config.hot_side.transformation_scheme is useDefault:
_log.warning(
"Discretization scheme was "
"not specified for the hot side of the "
"co-current heat exchanger. "
"Defaulting to backward finite "
"difference on the hot side."

if self.config.hot_side.transformation_scheme is useDefault:
_log.info(
"Discretization scheme was "
"not specified for the hot side of the "
"counter-current heat exchanger. "
"Defaulting to backward finite "
"difference on the hot side."
)
self.config.hot_side.transformation_scheme = "BACKWARD"
if self.config.cold_side.transformation_scheme is useDefault:
_log.info(
"Discretization scheme was "
"not specified for the cold side of the "
"counter-current heat exchanger. "
"Defaulting to backward finite "
"difference on the cold side."
)
self.config.cold_side.transformation_scheme = "BACKWARD"

if self.config.flow_type == HeatExchangerFlowPattern.cocurrent:
set_direction_hot = FlowDirection.forward
set_direction_cold = FlowDirection.forward
if self.config.hot_side.transformation_scheme != "BACKWARD":
_log_upwinding_disclaimer(
"hot_side",
"cocurrent",
self.config.hot_side.transformation_scheme,
"BACKWARD",
)
self.config.hot_side.transformation_scheme = "BACKWARD"
if self.config.cold_side.transformation_scheme is useDefault:
_log.warning(
"Discretization scheme was "
"not specified for the cold side of the "
"co-current heat exchanger. "
"Defaulting to backward finite "
"difference on the cold side."
if self.config.cold_side.transformation_scheme != "BACKWARD":
_log_upwinding_disclaimer(
"cold_side",
"cocurrent",
self.config.cold_side.transformation_scheme,
"BACKWARD",
)
self.config.cold_side.transformation_scheme = "BACKWARD"

elif self.config.flow_type == HeatExchangerFlowPattern.countercurrent:
set_direction_hot = FlowDirection.forward
set_direction_cold = FlowDirection.backward
if self.config.hot_side.transformation_method is useDefault:
_log.warning(
"Discretization method was "
"not specified for the hot side of the "
"counter-current heat exchanger. "
"Defaulting to finite "
"difference method on the hot side."
)
self.config.hot_side.transformation_method = "dae.finite_difference"
if self.config.cold_side.transformation_method is useDefault:
_log.warning(
"Discretization method was "
"not specified for the cold side of the "
"counter-current heat exchanger. "
"Defaulting to finite "
"difference method on the cold side."
)
self.config.cold_side.transformation_method = "dae.finite_difference"
if self.config.hot_side.transformation_scheme is useDefault:
_log.warning(
"Discretization scheme was "
"not specified for the hot side of the "
"counter-current heat exchanger. "
"Defaulting to backward finite "
"difference on the hot side."
if self.config.hot_side.transformation_scheme != "BACKWARD":
_log_upwinding_disclaimer(
"hot_side",
"countercurrent",
self.config.hot_side.transformation_scheme,
"BACKWARD",
)
self.config.hot_side.transformation_scheme = "BACKWARD"
if self.config.cold_side.transformation_scheme is useDefault:
_log.warning(
"Discretization scheme was "
"not specified for the cold side of the "
"counter-current heat exchanger. "
"Defaulting to forward finite "
"difference on the cold side."
if self.config.cold_side.transformation_scheme != "FORWARD":
_log_upwinding_disclaimer(
"cold_side",
"countercurrent",
self.config.cold_side.transformation_scheme,
"FORWARD",
)
self.config.cold_side.transformation_scheme = "BACKWARD"
else:
raise ConfigurationError(
"{} HeatExchanger1D only supports cocurrent and "
Expand Down Expand Up @@ -776,15 +805,16 @@ def initialize_build(
cold_side_units = (
self.cold_side.config.property_package.get_metadata().get_derived_units
)
t0 = self.flowsheet().time.first()
if duty is None:
duty = value(
0.25
* self.heat_transfer_coefficient[0, 0]
* self.heat_transfer_coefficient[t0, 0]
* self.area
* (
self.hot_side.properties[0, 0].temperature
self.hot_side.properties[t0, 0].temperature
- pyunits.convert(
self.cold_side.properties[0, 0].temperature,
self.cold_side.properties[t0, 0].temperature,
to_units=hot_side_units("temperature"),
)
)
Expand Down Expand Up @@ -881,3 +911,13 @@ def calculate_scaling_factors(self):
),
overwrite=False,
)


def _log_upwinding_disclaimer(side, flow_config, bad_scheme, good_scheme):
_log.info(
f"For {side}, a {bad_scheme} scheme was chosen to discretize the length domain. "
f"However, this scheme is not an upwind scheme for {flow_config} flow, and "
f"as a result may run into numerical stability issues. To avoid this, "
f"use a {good_scheme} scheme (which may result in energy conservation issues "
"for coarse discretizations) or use a high-order collocation method."
)

0 comments on commit f0c60c4