Expand Up @@ -121,28 +121,28 @@ If the `MAX_CELL_VOLTAGE` \* `cell count` is reached for `MAX_VOLTAGE_TIME_SEC`

## BMS feature comparison

| Feature | Ant | Daly | ECS | HLPdataBMS4S | JK BMS | Life/Tian Power | LLT/JBD | MNB <sup>(1)</sup> | Renogy | Seplos | Sinowealth <sup>(1)</sup> |
| ---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| Voltage | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Current | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Power | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| State Of Charge | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Battery temperature | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| MOSFET temperature | No | No | No | No | Yes | No | Yes | No | No | No | No |
| Consumed Ah | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Time-to-go | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc |
| Min/max cell voltages | Yes | Yes | No | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Min/max temperature | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Installed capacity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Available capacity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Cell details | No | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | ? |
| Balancing status | Yes | No | Yes | No | Yes | Yes | No | No | No | No | ? |
| Raise alarms from the BMS | Yes | Yes | Yes <sup>(2)</sup> | Yes | Yes | Yes | Yes | Yes | Yes | Yes | ? |
| History of charge cycles | Yes | Yes | No | No | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Get CCL/DCL from the BMS | No | No | No | No | Yes | No | No | No | No | No | No |
| Charge current control management (CCCM) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Set battery parameters (DVCC) | Calc | Calc | Yes | Yes | Calc | Calc | Calc | Yes | Calc | Calc | Calc |
| Bluetooth connection <img src="../img/bluetooth.svg" className="h-1em" /> | No | No | No | No | Yes | No | Yes | No | No | No | No |
| Feature | Ant | Daly | ECS | Heltec | HLPdataBMS4S | JK BMS | Life/Tian Power | LLT/JBD | MNB <sup>(1)</sup> | Renogy | Seplos | Sinowealth <sup>(1)</sup> |
| ---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| Voltage | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Current | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Power | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| State Of Charge | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Battery temperature | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| MOSFET temperature | No | No | No | Yes | No | Yes | No | Yes | No | No | No | No |
| Consumed Ah | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Time-to-go | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc | Calc |
| Min/max cell voltages | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Min/max temperature | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Installed capacity | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Available capacity | Yes | Yes | Yes | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Cell details | No | Yes | Yes | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | ? |
| Balancing status | Yes | No | Yes | Yes | No | Yes | Yes | No | No | No | No | ? |
| Raise alarms from the BMS | Yes | Yes | Yes <sup>(2)</sup> | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | ? |
| History of charge cycles | Yes | Yes | No | No | No | Yes | Yes | Yes | No | Yes | Yes | Yes |
| Get CCL/DCL from the BMS | No | No | No | Yes | No | Yes | No | No | No | No | No | No |
| Charge current control management (CCCM) | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Set battery parameters (DVCC) | Calc | Calc | Yes | Calc | Yes | Calc | Calc | Calc | Yes | Calc | Calc | Calc |


`Calc` means that the value is calculated by the driver.