Dimethyl 3plex error in combining experiments and estimating protein intensity #1476

Closed
FriedLabJHU opened this issue Mar 4, 2024 · 1 comment
Assignees
Labels

Comments

@FriedLabJHU
Copy link

  • Describe the issue or question:
    Using the SILAC3 workflow for dimethyl 3plex labeled samples, I keep getting the following error:
2024-03-04 16:38:28 [INFO] - Combining experiments and estimating protein intensity...
java.lang.ArrayIndexOutOfBoundsException: Index -476 out of bounds for length 40007
	at r.a(Unknown Source)
	at r.<init>(Unknown Source)
	at ionquant.IonQuant.main(Unknown Source)
2024-03-04 16:38:29 [ERROR] - Index -476 out of bounds for length 40007
Process 'IonQuant' finished, exit code: 1

log_2024-03-04_16-38-29.txt

@fcyu fcyu self-assigned this Mar 4, 2024
@fcyu
Copy link
Member

fcyu commented Mar 4, 2024

Known bug: #1387

Could you send an email to yufe AT umich.edu to get the fixed version?

Thanks,

Fengchao

@fcyu fcyu closed this as completed Mar 5, 2024
@fcyu fcyu added the IonQuant label Apr 19, 2024