Skip to content

Measurement Setups

Shanon Pearce edited this page Jan 22, 2022 · 44 revisions

A summary of the binaural measurement setups for each of the rooms is provided in the table below. The rooms have been sorted by room ID.

Room ID Room name Listener Source distance (m) Source azimuth range Source elevation range No. of sets of positions
R01 Room Calypso KEMAR 45BA with large ears 2.50 ±180° 1
R02 Control Room 1 Neumann KU100 2.80 ±180° 1
R03 Listening Room B&K HATS Type 4100 3.10 ±180° 1
R04 Control Room 7 Neumann KU100 3.00 ±180° 1
R05A Audio Lab (with absorbers) KEMAR 45BA with large ears 2.50 ±180° 1
R05B Audio Lab (without absorbers) KEMAR 45BA with large ears 2.50 ±180° 1
R06 Seminar Room, TU Ilmenau KEMAR 3.35 (P1), 3.00 (P2) ±180° 2
R07 Conference Room KEMAR 45BA with large ears (P1,P2) and small ears (P3) 2.50 ±180° 3
R08 Room Spirit KEMAR 45BA with large ears 2.00 ±120° 1
R09 Adream Laboratory KEMAR 45BB-4 5.30 (P1), 4.80 (P2) ±180° 2
R10 Room Auditorium 3 KEMAR 45BA with large ears 4.00 ±180° 1
R11 Small Broadcast Studio Neumann KU100 6.94 (P1) ±180° 2
R12 Stairway HMS2 artificial head by HEAD acoustics 3.00 ±90° 1
R13 Office Neutrik Cortex mk.2 HATS 1.50 ±90° 1
R14 Classroom Neutrik Cortex mk.2 HATS 1.50 ±90° 1
R15 Seminar Room, University of Surrey Neutrik Cortex mk.2 HATS 1.50 ±90° 1
R16 Large Broadcast Studio Neumann KU100 15.80 ±180° 1
R17 Room HU201 Individual listener 2.20 ±180° 1
R18 Rehabilitation Room KEMAR 45BA with large ears 2.00 ±180° 1
R19 Coupled Rooms FABIAN HATS 3.97 (L), 3.01 (R) ±45° 1
R20 Seminar Room, RWTH Aachen FABIAN HATS 5.25 (P1), 4.00 (P2) ±45° 2
R21 Chamber Music Hall FABIAN HATS 10.00 ±45° 1
R22 Large Room KEMAR DB-4004 with normal ears 5.08 (P1), 9.67 (P2) ±180° 2
R23 Small Room A Neumann KU100 4.00 ±180° 1
R24 Seminar Room, TU Berlin KEMAR DB-4004 with normal ears 3.07 ±180° 1
R25 TV Studio KEMAR 6.25 ±180° 1
R26 Small Room B KEMAR DB-4004 with normal ears 4.12 ±180° 1
R27 Lecture Room A Neumann KU100 6.08 ±120° 1
R28 Small Room C Neumann KU100 2.60 ±180° 1
R29 Studio A FABIAN HATS 7.55 ±180° 1
R30 Small Room D B&K HATS Type 4100 3.00 ±180° 1
R31 Studio B Neumann KU100 5.93 ±180° 1
R32 Concert Hall B&K HATS Type 4053 N/A ±135° 1
R33 Studio C Neumann KU100 6.48 ±180° 1
R34 Studio D Neumann KU100 5.69 ±180° 1
R35 Small Room E Neumann KU100 3.00 ±180° 1
R36 Studio E Neumann KU100 3.82 ±180° 1
R37 Lecture Room B Neumann KU100 3.99 ±180° 1
R38 Small Room F FABIAN HATS 3.55 ±180° 1
R39 Small Room G FABIAN HATS (P1), Neumann KU100 (P2) 3.25 ±180° 2