Measurement Setups
Shanon Pearce edited this page Jan 22, 2022
·
44 revisions
A summary of the binaural measurement setups for each of the rooms is provided in the table below. The rooms have been sorted by room ID.
Room ID | Room name | Listener | Source distance (m) | Source azimuth range | Source elevation range | No. of sets of positions |
---|---|---|---|---|---|---|
R01 | Room Calypso | KEMAR 45BA with large ears | 2.50 | ±180° | 0° | 1 |
R02 | Control Room 1 | Neumann KU100 | 2.80 | ±180° | 0° | 1 |
R03 | Listening Room | B&K HATS Type 4100 | 3.10 | ±180° | 0° | 1 |
R04 | Control Room 7 | Neumann KU100 | 3.00 | ±180° | 0° | 1 |
R05A | Audio Lab (with absorbers) | KEMAR 45BA with large ears | 2.50 | ±180° | 0° | 1 |
R05B | Audio Lab (without absorbers) | KEMAR 45BA with large ears | 2.50 | ±180° | 0° | 1 |
R06 | Seminar Room, TU Ilmenau | KEMAR | 3.35 (P1), 3.00 (P2) | ±180° | 0° | 2 |
R07 | Conference Room | KEMAR 45BA with large ears (P1,P2) and small ears (P3) | 2.50 | ±180° | 0° | 3 |
R08 | Room Spirit | KEMAR 45BA with large ears | 2.00 | ±120° | 0° | 1 |
R09 | Adream Laboratory | KEMAR 45BB-4 | 5.30 (P1), 4.80 (P2) | ±180° | 0° | 2 |
R10 | Room Auditorium 3 | KEMAR 45BA with large ears | 4.00 | ±180° | 0° | 1 |
R11 | Small Broadcast Studio | Neumann KU100 | 6.94 (P1) | ±180° | 0° | 2 |
R12 | Stairway | HMS2 artificial head by HEAD acoustics | 3.00 | ±90° | 0° | 1 |
R13 | Office | Neutrik Cortex mk.2 HATS | 1.50 | ±90° | 0° | 1 |
R14 | Classroom | Neutrik Cortex mk.2 HATS | 1.50 | ±90° | 0° | 1 |
R15 | Seminar Room, University of Surrey | Neutrik Cortex mk.2 HATS | 1.50 | ±90° | 0° | 1 |
R16 | Large Broadcast Studio | Neumann KU100 | 15.80 | ±180° | 0° | 1 |
R17 | Room HU201 | Individual listener | 2.20 | ±180° | 0° | 1 |
R18 | Rehabilitation Room | KEMAR 45BA with large ears | 2.00 | ±180° | 0° | 1 |
R19 | Coupled Rooms | FABIAN HATS | 3.97 (L), 3.01 (R) | ±45° | 0° | 1 |
R20 | Seminar Room, RWTH Aachen | FABIAN HATS | 5.25 (P1), 4.00 (P2) | ±45° | 0° | 2 |
R21 | Chamber Music Hall | FABIAN HATS | 10.00 | ±45° | 0° | 1 |
R22 | Large Room | KEMAR DB-4004 with normal ears | 5.08 (P1), 9.67 (P2) | ±180° | 0° | 2 |
R23 | Small Room A | Neumann KU100 | 4.00 | ±180° | 0° | 1 |
R24 | Seminar Room, TU Berlin | KEMAR DB-4004 with normal ears | 3.07 | ±180° | 0° | 1 |
R25 | TV Studio | KEMAR | 6.25 | ±180° | 0° | 1 |
R26 | Small Room B | KEMAR DB-4004 with normal ears | 4.12 | ±180° | 0° | 1 |
R27 | Lecture Room A | Neumann KU100 | 6.08 | ±120° | 0° | 1 |
R28 | Small Room C | Neumann KU100 | 2.60 | ±180° | 0° | 1 |
R29 | Studio A | FABIAN HATS | 7.55 | ±180° | 0° | 1 |
R30 | Small Room D | B&K HATS Type 4100 | 3.00 | ±180° | 0° | 1 |
R31 | Studio B | Neumann KU100 | 5.93 | ±180° | 0° | 1 |
R32 | Concert Hall | B&K HATS Type 4053 | N/A | ±135° | 0° | 1 |
R33 | Studio C | Neumann KU100 | 6.48 | ±180° | 0° | 1 |
R34 | Studio D | Neumann KU100 | 5.69 | ±180° | 0° | 1 |
R35 | Small Room E | Neumann KU100 | 3.00 | ±180° | 0° | 1 |
R36 | Studio E | Neumann KU100 | 3.82 | ±180° | 0° | 1 |
R37 | Lecture Room B | Neumann KU100 | 3.99 | ±180° | 0° | 1 |
R38 | Small Room F | FABIAN HATS | 3.55 | ±180° | 0° | 1 |
R39 | Small Room G | FABIAN HATS (P1), Neumann KU100 (P2) | 3.25 | ±180° | 0° | 2 |