Smart meter manufacturer Model Interface socket Baud rate Parity Encryption Physical signal interface Known countries
Note 1
Payload protocol Standard Our product
Aidon with built-in interface 6442, 6490, 6492 RJ11/12 115200 8N1 No Open collector Sweden P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Aidon with built-in interface 65xx, 6474, 6476, 6477, 6479, 6484 RJ45 ("Ethernet") 2400 8E1 No M-bus 24/12V (HAN-NVE) Norway, Sweden HAN-NVE (HDLC/DLMS/COSEM) EN-IEC 62056-7-5 Pow-U with RJ45 cable
Aidon with Rejlers Politerm interface 65xx, 6474, 6476, 6477, 6479, 6484 RJ45 ("Ethernet") 2400 8N1 No M-bus 24/12V (HAN-NVE) Norway HAN-NVE (HDLC/DLMS/COSEM) EN-IEC 62056-7-5 Pow-U with RJ45 cable
Iskraemeco AM550 RJ11/12 115200 8N1 No Open collector P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Kaifa/Nuri "MA105H2E MA304H3E MA304H4 MA304T3 MA304T4" RJ45 ("Ethernet") 2400 8E1 No M-bus 24/12V (HAN-NVE) Norway HAN-NVE (HDLC/DLMS/COSEM) EN-IEC 62056-7-5 Pow-U with RJ45 cable
Kaifa/Nuri MA309M RJ11/12 2400 8N1 Country / Network operator dependent M-bus 34/22V Austria HDLC/DLMS/COSEM Pow-U with RJ12 cable
Kamstrup Omnia Omnia E-meter RJ11/12 115200 8N1 No Open collector Denmark, Sweden P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Kamstrup Omnipower with HAN-NVE adapter 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 RJ45 ("Ethernet") 2400 8N1 Country / Network operator dependent M-bus 24/12V (HAN-NVE) Norway, Sweden, Denmark, Switzerland HDLC/DLMS/COSEM EN-IEC 62056-7-5 Pow-U with RJ45 cable
Note 2
Kamstrup Omnipower with P1 adapter 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 RJ11/12 115200 8N1 No Open collector Denmark, Sweden P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable and modification (Notify us when ordering)
Note 3
Kamstrup Omnipower, without adapter, HAN-NVE configuration 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 6-pin plug in expansion bay 2400 8N1 Country / Network operator dependent TTL 3.3V Norway, Sweden, Denmark, Switzerland HDLC/DLMS/COSEM EN-IEC 62056-7-5 Pow-K
Kamstrup Omnipower, without adapter, P1 configuration 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 6-pin plug in expansion bay 115200 8N1 No TTL 3.3V Sweden, Denmark ? P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-K
Landis & Gyr with Embriq Politerm800 module E350 RJ45 2400 8N1 No M-bus 24/12V (HAN-NVE) Norway (Klive nett) HAN-NVE (HDLC/DLMS/COSEM) EN-IEC 62056-7-5 Pow-U with RJ45 cable
Landis & Gyr E360 RJ11/12 115200 8N1 No Open collector Sweden, Denmark, P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Landis + Gyr E450 S4, S5 RJ11/12 2400 8E1 Country / Network operator dependent M-bus 34/22V Austria, Switzerland HDLC/DLMS/COSEM Pow-U with RJ12 cable
Landis + Gyr E450 S4, S5 RJ11/12 2400 8N1 Country / Network operator dependent M-bus 24/12V Austria: Netz Burgenland Network operator specific (ASCII) Pow-U with RJ12 cable
NES G5 83335-X RJ11/12 115200 8N1 No Open collector Denmark P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Sagemcom S211, T211 RJ11/12 115200 8N1 No Open collector Sweden P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Sagemcom T210-D, S210 RJ11/12 2400 8N1 Country / Network operator dependent M-bus 34/22V (Is this wrong?) Austria HDLC/DLMS/COSEM Pow-U with RJ12 cable
Sanxing S34U18 RJ11/12 115200 8N1 No Open collector Sweden P1-DSMR v5.0.2 EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable
Sanxing S34U18 RJ11/12 115200 8N1 No Open collector Hungary EON payload EN-IEC 62056-21 Mode D Pow-P1 with RJ12 cable

Note

Note 1: Please notify us if other countries should be added to the table!

Note 2: Might need USB power to operate. For Kamstrup Omnipower meters we recommend using Pow-K (without using the HAN-NVE module). Pow-U + RJ45 cable can be a solution in cases where there is no Wi-Fi coverage at the location of the power meter.

Note 3: Needs USB power to operate, as the Kamstrup HAN-P1 adapter does not deliver power. For Kamstrup Omnipower meters we recommend using Pow-K (without using the HAN-P1 module). A modified Pow-P1 + RJ12 cable can be a solution in cases where there is no Wi-Fi coverage at the location of the power meter.