Skip to content

On Mitel 6869i 4.5.0.41 devices, the Manual Firmware...

High severity Unreviewed Published Jun 9, 2024 to the GitHub Advisory Database • Updated Jun 12, 2024

Package

No package listedSuggest a package

Affected versions

Unknown

Patched versions

Unknown

Description

On Mitel 6869i 4.5.0.41 devices, the Manual Firmware Update (upgrade.html) page does not perform sanitization on the username and path parameters (sent by an authenticated user) before appending flags to the busybox ftpget command. This leads to $() command execution.

References

Published by the National Vulnerability Database Jun 9, 2024
Published to the GitHub Advisory Database Jun 9, 2024
Last updated Jun 12, 2024

Severity

High
8.8
/ 10

CVSS base metrics

Attack vector
Network
Attack complexity
Low
Privileges required
Low
User interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H