Skip to content

On Triangle MicroWorks' SCADA Data Gateway version <= v5...

Critical severity Unreviewed Published Jun 7, 2023 to the GitHub Advisory Database • Updated Apr 4, 2024

Package

No package listedSuggest a package

Affected versions

Unknown

Patched versions

Unknown

Description

On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.

References

Published by the National Vulnerability Database Jun 7, 2023
Published to the GitHub Advisory Database Jun 7, 2023
Last updated Apr 4, 2024

Severity

Critical

Weaknesses

CVE ID

CVE-2023-2186

GHSA ID

GHSA-gqvf-fxmv-5gj9

Source code

No known source code

Dependabot alerts are not supported on this advisory because it does not have a package from a supported ecosystem with an affected and fixed version.